Kogan Smart Bluetooth Body Fat Scale

Model: KABFSBTAPPB

USER MANUAL

Introduction

Thank you for selecting the Kogan Smart Bluetooth Body Fat Scale. The scale measures weight and uses bio-electrical impedance analysis (BIA) technology to estimate body fat, total body water percentage, bone mass and muscle mass in generally healthy children from 14-17 years old and healthy adults.

Safety Information

The symbols below may appear in the user manual, labelling or other components. Please follow all instructions.

Caution

Usage Tips

Product Overview

Device Components

Description of scale components:

Diagram description: The scale has a flat, square surface with electrodes. The underside features a UNIT button and a battery compartment.

Contents List

LCD Display

The LCD display shows various units and status indicators:

Initial Start-Up

General Instructions

The Kogan smart scale applies BIA (Bio-impedance Analysis) technology. A small amount of weak current flows through the human body so as to detect the bio-impedence and estimate body fat. The electric current is so small as to not be felt by the user. BIA technology is safe, non-invasive, toxin-free and harmless. The current used is less than 1mA, however anyone wearing any form of electronic medical implant such as a pacemaker must avoid using this device.

Inserting the Batteries

  1. Open the battery door in the back of the scale.
  2. Insert the batteries (4 x 1.5V AAA) into the battery compartment, making note of the polarity indicators marked inside the compartment.
  3. The digits "8888" will be shown on the LCD.
  4. Close the battery door and wait until the digits "0.0lb" are shown on the LCD.

Caution

Installing the App and Pairing Up

  1. With Bluetooth 4.0 technology applied, mobile or portable equipment is capable of receiving your personal health data.
  2. Simply install the MedM App from the App store or Google Play.
  3. Turn on Bluetooth and start the application, then ensure the scale is turned on before pairing.
  4. Press and hold the [UNIT Button] on the back of the scale to pair up. A symbol of two small circles spinning around each other (?) will display to indicate that pairing is proceeding.
    • If successful, a linked square icon (?) will show on the LCD.
    • If the pairing fails, an E1 error symbol (E1) will show on the LCD.

Selecting Measurement Unit

With the batteries installed, press the [UNIT Button] in the back of the scale to select your preferred measurement unit. The default measurement unit is lbs (pounds). You may press UNIT to choose between pounds, kilograms or stone.

Diagram description: LCD showing '00' for unit selection, and '00 - 0.00' for measurement.

Measuring

Daily Measurement

The scale will turn on as soon as you step onto the platform in bare feet.

Stand still and keep full contact with the [Electrode]s. The weight unit will flash, then the weight measurement will be locked. When the moving "o" animation stops, the LCD will display the weight and body fat measurement.

When the scale is successfully paired with the smartphone and the Bluetooth is turned on, the data transfer will begin automatically. (Please refer to 'Data Transmission' below for more details)

Data Management

Data Transmission

With the scales successfully paired up with your smartphone, measurement data will be automatically transmitted to your mobile via Bluetooth.

The ✔️ symbol will disappear once the data transfer has complete successfully. You may then check your health data on your phone.

If the data transmission fails, the ? symbol will remain on the screen. The pending data will be stored in the scale and transmitted to your smartphone when the next measurement is taken.

Caution

How to avoid possible interference?

  1. The range between the scales and the Bluetooth device should be reasonably close, anywhere between 1 and 10 metres. Please ensure that there are no objects between the scale and the Bluetooth device.
  2. To avoid interference, other wireless/Bluetooth enabled devices should be kept away from the scales while transmission is taking place.

Troubleshooting

Error Prompts

ErrorDescriptionSolution
[Overload Symbol]Overload - Device will power off.Stop using the scale for measurement.
[Low Battery Symbol]Low battery - Device will power off.Replace all four batteries at the same time.
[Pairing Failure Symbol]Pairing failurePlease check:
• Bluetooth is ON
• The App is ON
• Both devices are within transmitting distance.

During Measurement

ProblemCauseSolution
Abnormal results such as:
• Too high
• Too low
• Huge differences between consecutive measurements
Incorrect posturePlease step onto platform in bare feet and stand still.
Scale is on soft carpet or unstable surfacePlace the device on a hard, flat surface.
Cold body that may result in bad blood circulationWarm your hands and feet to improve blood circulation then measure again.
Cold electrodesPlace the device in a warm room for awhile, then try again.
Hands or feet are too dryWipe your feet with a damp cloth, making them slightly damp.
No display on LCD when device powers on.Batteries not installedInstall the batteries into the unit.
Worn or flat batteriesReplace all four batteries at the same time.
Cannot proceed to analyse body fat.Stepping onto scale wearing socks or shoesStay in bare feet during measurement, keeping full contact with the electrodes at all times.
Device powers off automaticallyLow batteryReplace all four batteries at the same time.

During Data Transmission

ProblemCauseSolution
Data transmission failedBluetooth is OFFTurn on Bluetooth via the settings.
App is not runningPress the [App Icon] to run the App.
Devices are out of rangePlace your smartphone closer to the scale.

Specifications

SpecificationDetails
Dimension320 x 330 x 27.2mm (approximately)
Net weightApproximately 1.75kg (excluding batteries)
DisplayDigital LCD with white backlight
Measurement unitsKilograms/Pounds/Stone
Measurement range5kg~180kg/0st 11lb ~ 28st 5lb / 11lb ~ 397lb
Division0.1kg / 0.2lb
Accuracy0-50kg: ±0.3kg; 50-100kg: ±0.4kg; 100-150kg: ±0.5kg; 150-180kg: ±0.7kg
Working environmentTemp: 5~40°C Humidity: <90% RH
Storage environmentTemp: -20~60°C Humidity: <93% RH
Power source6V (4 x AAA batteries)
Turn on methodSense on Technology
Auto-OFFScale will shut down after 10 seconds of no operations.
Accessories4 x AAA batteries
1 x user manual
Mode of operationContinuous operation
Bluetooth module no.AW8001

About the accuracy of this product

Maintenance

When carrying out usual maintenance, please ensure you follow these do's and don'ts:

Warranty

Kogan.com warrants this scale to be free of defects and workmanship under normal use for a period of ONE year from the date of purchase.

The warranty does not cover damage caused by misuse or abuse, including, but not limited to:

Should this device require any maintenance or repairs, please contact the Kogan.com customer support team.

Appendix

Table of Body Fat Level (Unit: %)

AgeMan / SportsmanWoman / Sportswoman
LowNormalHighV. HighLowNormalHighV. High
20~29<1313.1-2020.1 - 23>23<1919.1-2828.1-31>31
30~39<1414.1-2121.1-24>24<2020.1-2929.1-32>32
40~49<1616.1-2323.1-26>26<2222.1-3030.1-33>33
50~59<1717.1-2424.1-27>27<2323.1-3131.1-34>34
60+<1818.1-2525.1-28>28<2424.1-3232.1-35>35

Table of Body Water Level (Unit: %)

GenderBody Fat Percentage RangeOptimal Total Body Water Percentage Range
Male4-1470-63
15-2163-57
22-2557-55
>25.155-37
Female4-2070-58
21-2958-52
30-3352-49
>3349-37

Source: derived from Wang & Deurenberg: "Hydration of fat-free body mass". American Journal Clin Nutr 1999, 69833-841

Health Tips - About Body Fat

Fat is essential to the human body. It not only stores energy and protects viscera, but it also regulates body temperature and maintains the normal physiological function of the human body. However, too much body fat is harmful to the human body, as it can lead to fatty liver, diabetes, coronary heart disease etc...

Self-measuring and self-monitoring your body fat levels is beneficial to your health. Body fat levels cannot be judged simply by weight.

EMC Guidance

Table 1 - Guidance and manufacturer's declaration – electromagnetic emissions for all ME equipment and ME systems.

Guidance and manufacturer's declaration - electromagnetic emissions
Emissions testComplianceElectromagnetic environment guidance
RF emissions CISPR 11Group 2The device must emit electromagnetic energy in order to perform its intended function. Nearby electronic equipment may be affected.
RF emissions CISPR 11Class B
Harmonic emissions IEC 61000-3-2Not applicable
Voltage fluctuations/flicker emissions IEC 61000-3-3Not applicable

Table 2 - Guidance and manufacturer's manufacturer's declaration – electromagnetic immunity for all ME equipment and ME systems.

Guidance and manufacturer's declaration – electromagnetic immunity
Immunity testIEC 60601 test levelCompliance levelElectromagnetic environment guidance
Electrostatic discharge (ESD) IEC 61000-4-2±6 kV contact
±8 kV air
±6 kV contact
±8 kV air
Floors should be wood, concrete or ceramic tile. If floors are covered with synthetic material, the relative humidity should be at least 30%.
Electrical fast transient/burst IEC 61000-4-4±2 kV for power supply lines
±1 kV for input/output lines
Not applicableMains power quality should be that of a typical commercial or hospital environment.
Surge IEC 61000-4-5±1 kV line(s) to line(s)
±2 kV line(s) to earth
Not applicableMains power quality should be that of a typical commercial or hospital environment.
Voltage dips, short interruptions and voltage variations on power supply input lines IEC 61000-4-11<5% UT (>95% dip in UT) for 0,5 cycle
40% UT (60% dip in UT) for 5 cycles
70% UT (30% dip in UT) for 25 cycles
<5% UT (>95% dip in UT) for 5 s
Not applicableMains power quality should be that of a typical commercial or hospital environment. If the user of the device requires continued operation during power mains interruptions, it is recommended that the device be powered from a non-interruptible power supply or battery.

EMC Guidance

Table 4 – Guidance and manufacturer's declaration – electromagnetic immunity for all ME equipment and ME systems that are NOT life supporting.

Guidance and manufacturer's declaration – electromagnetic immunity
Immunity testIEC 60601 test levelCompliance levelElectromagnetic environment guidance
Power frequency (50/60Hz) magnetic field IEC 61000-4-83 A/m3 A/mPower frequency magnetic fields should be at levels characteristic of a typical location in a typical commercial or hospital environment.
Conducted RF IEC 61000-4-63 Vrms 150 kHz to 80 MHzNot applicable
Radiated RF IEC 6100-4-33 V/m 80 MHz to 2,5 GHz3 V/mPortable and mobile RF communications equipment should be used no closer to any part of the device, including cables, than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter.
Recommended separation distance:
d = [√P] x 7 (150 kHz to 80 MHz)
d = 1.167 √P (80 MHz to 800 MHz)
d = 2.333 √P (800 MHz to 2,5 GHz)
Where P is the maximum output power rating of the transmitter in watts (W), according to the transmitter manufacturer and d is the recommended separation distance in metres (m).
Field strengths from fixed RF transmitters, as determined by an electromagnetic site surveyª, should be less than the compliance level in each frequency rangeᵇ.
Interference may occur in the vicinity of equipment marked with the following symbol: ((()))

Note 1: At 80MHz and 800MHz, the higher frequency range applies.

Note 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people.

a) Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the device is used exceeds the applicable RF compliance level above, the device should be observed to verify normal operation. If abnormal operations are observed, additional measures may be necessary, such as re-orienting or relocating the device.

b) Over the frequency range 150kHz to 80MHz, field strengths should be less than [V1] V/m.

Recommended separation distances between portable and mobile RF communications equipment and the ME equipment or ME system - for ME equipment and ME systems that are NOT life supporting.

Table 6 - Recommended separation distances between portable and mobile RF communications equipment and the device

The device is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the device can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the device as recommended below, according to the maximum output power of the communications equipment.

Rated maximum output power of transmitter WSeparation distance according to frequency of transmitter m
150kHz to 80MHz
d = [35]√P
80MHz to 800MHz
d = 1.167 √P
800MHz to 2,5GHz
d = 2.333 √P
0.01Not applicable0.1170.233
0.1Not applicable0.3690.738
1Not applicable1.1672.333
10Not applicable3.6907.378
100Not applicable11.6723.33

For transmitters rated at a maximum output power not listed above, the recommended separation distance d in metres (m) can be estimated using the equation applicable to the frequency of the transmitter, where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer.

Note 1: At 80MHz and 800MHz, the separation distance of the higher frequency range applies.

Note 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflections from structures, objects and people.

PDF preview unavailable. Download the PDF instead.

KABFSBTAPPB-B Adobe Acrobat Pro 10.1.16

Related Documents

Preview Kogan KADGLBWSCLA Digital Body Weight Scale User Manual & Health Guide
Comprehensive user manual for the Kogan KADGLBWSCLA Digital Body Weight Scale. Learn how to set up, use, and maintain your scale for accurate body composition analysis, including body fat, water, muscle, and bone mass. Includes health tips and troubleshooting.
Preview Kogan SmarterHome WiFi Body Composition Smart Scale User Manual
User manual for the Kogan SmarterHome WiFi Body Composition Smart Scale (KASHBDYSCLA), covering safety information, setup, measurement, data management, troubleshooting, and specifications.
Preview Kogan KADIGTHSCAA Slim Digital Kitchen Scales User Manual
Comprehensive user manual for the Kogan KADIGTHSCAA Slim Digital Kitchen Scales, detailing features, operation, and important safety information for accurate home use.
Preview Kogan Aura Smart Ring User Guide - Setup, Features, and Specifications
Comprehensive user guide for the Kogan Aura Smart Ring. Learn how to set up, charge, connect to the QRing app, and utilize its features for tracking activity, sleep, and heart rate.
Preview Kogan Slimline Full Body Massage Chair User Guide | KAMGC HRBRWA & KAMGCHRGRYA
Comprehensive user guide for the Kogan Slimline Full Body Massage Chair (KAMGCHRBRWA & KAMGCHRGRYA), covering essential safety instructions, operation, installation, cleaning, troubleshooting, and technical specifications for optimal home use.
Preview Kogan Bluetooth Audio Adapter User Guide
Comprehensive user guide for the Kogan Bluetooth Audio Adapter (Model: KABTAADAPTA), detailing setup, operation, safety precautions, and technical specifications for seamless wireless audio streaming.
Preview Kogan KASBRBTAIOB Bluetooth Soundbar User Manual and Guide
Comprehensive user manual for the Kogan KASBRBTAIOB Bluetooth Soundbar, covering setup, operation, safety, and troubleshooting. Learn how to connect, control, and enjoy your soundbar.
Preview Kogan SmarterHome 10W Smart Bulb User Guide
User guide for the Kogan SmarterHome 10W Colour & Warm/Cool White Smart Bulb (B22, Wi-Fi & Bluetooth), covering setup, operation, and integration with Google Home and Amazon Alexa.