Extol Craft 414122 Submersible Sewage Pump

IMPROVE YOUR DAY!

Introduction

Thank you for choosing the Extol® Craft 414122 submersible sewage pump. This product has undergone rigorous testing for reliability, safety, and quality, adhering to European Union standards and regulations. For any inquiries, please contact our customer and consulting center:

Manufacturer: Madal Bal a. s., Průmyslová zóna Příluky 244, 76001 Zlín, Czech Republic

Date of issue: 06/2025

I. Technical Specifications

Specification Value
Order Number 414122
Power Input 400 W
Supply Voltage/Frequency 220-240 V~50 Hz
Maximum Flow Rate 7500 l/h
Max. Delivery Height 5 m
Max. Pump Submersion Depth 5 m
Hose Connection Fitting Diameters 1 1/4"; 32mm; 1"; 25 mm
Power Cord Length 10 m
Max. Size of Particles Dispersed in Liquid 35 mm
For Clean and Dirty Water YES
Weight (without power cord) 3.3 kg
IP Code IPX8
pH Range for Pumped Liquid 4-9
Temperature of Pumped Liquid +3°C < t ≤ 35°C
Ambient Air Temperature 5-35°C
Material of Pump Unit Plastic

The pump's performance is divided between suction depth, delivery height, and flow rate. To achieve maximum delivery height, the suction depth must be as small as possible. For maximum flow rate at the outlet, suction depth and delivery height must be as small as possible. The pump's flow rate decreases proportionally with increasing hose length and liquid viscosity, increasing height difference between pump and hose end, hose diameter and resistance, decreasing water temperature, or voltage drop.

Figure 1: Relationship of delivery flow rate (m³/h) to delivery height (m).

II. Characteristics – Purpose of Use

The Extol® Craft 414122 electric submersible pump is designed for pumping, draining, or transferring water in domestic, garden, or recreational settings. Its ability to handle larger particles makes it suitable for pumping dirty water. The pump is intended for smaller-scale pumping tasks and is not recommended for prolonged submersion, such as in drainage sumps for controlled drainage of rising groundwater.

This pump is NOT designed for pumping the following liquids:

III. Parts and Control Elements

Refer to Figure 3 for component identification:

  1. Handle for attaching the pump's suspension rope and for carrying.
  2. Outflow fitting (elbow) with a 1 1/4" male thread.
  3. Base (stand) of the pump.
  4. Float switch (float).
  5. Power cord.
  6. Fixture for holding the float switch cord to regulate the water level.
  7. Hose connection fitting for diameters of 25 mm; 1" and 32 mm.

The adjustable float cord length allows setting the water level for pump activation and deactivation (see Figure 2).

Figure 2: Pump operation with float switch.

IV. Before Putting into Operation

ATTENTION: Carefully read this entire manual before first use and keep it with the product. Ensure the product is not damaged. Make sure the pump's power cord is disconnected from the power outlet.

1. Inspection

V. Operating the Pump

Placement into the Pumped Liquid

  1. Lower the pump into the pumped liquid.
  2. Place the pump directly on a firm, level bottom free of debris. Ensure the bottom is not deeper than the maximum submersion depth.
  3. If the bottom conditions are not met, suspend the pump freely on a rope or chain, adhering to the maximum submersion depth. Ensure the liquid does not contain forbidden substances.
  4. Secure the pump vertically to prevent movement or falling. Ensure the power cord is not trapped under the pump.

ATTENTION: Ensure the float switch has free movement. If the float switch gets stuck, the pump may run dry and be damaged.

Remove any large objects from the pumping area before submerging the pump.

Always position the pump vertically. Never lower the pump by its power cord.

Figure 5: Pump placement.

Turning On / Off

Note: The pump has thermal protection. If activated, disconnect power, remove the cause of overheating, and allow the motor to cool. Do not overload the pump.

ATTENTION: Always disconnect the pump from the power supply before removing it from the liquid.

Fundamentals of Working with the Pump and Safety Instructions

VI. Cleaning and Maintenance

ATTENTION: Disconnect the power cord before any handling.

Troubleshooting

ATTENTION: Before starting repairs or adjustments, always disconnect the power cord from the power socket.

Defect Possible Cause Remedy
The pump does not start up when turned on, the motor is silent. No voltage in the power grid.
Faulty power socket.
Damaged extension cord.
Float switch is blocked.
Check voltage source, circuit breaker, RCD.
Use a different power socket.
Check and replace the power cord if necessary.
Release and adjust the float switch.
The pump does not start up when turned on, the motor is humming. Thermal protection activated.
The impeller is blocked.
Allow the pump's electric motor to cool down and remove the cause of activation.
Disassemble the base and clean the impeller area. Rotate the impeller. Contact Extol® service.
The pump starts up but its performance is weak and it is noisy. The delivery hose or suction system is clogged.
Worn out impeller.
Clean the hose or impeller area.
Contact Extol® service for replacement.
Water in the area of the pump's terminal box or the motor winding. Fluctuating voltage in the power grid. Stabilize the power grid voltage.
The pump starts and stops on its own. Damaged mechanical seal or sealing rings.
Damaged motor body.
Low resistance of the delivered liquid.
Contact Extol® service for repair.
Contact Extol® service for repair.
Increase the resistance of the delivered liquid (e.g., by connecting a longer delivery hose).

If the fault cannot be remedied without working on the inner parts of the pump, have it repaired at an authorized Extol® service center. For warranty repairs, contact your retailer.

VII. References on the Rating Label and Symbols

See the rating label and symbols for important information:

VIII. Storage

IX. Waste Disposal

X. Warranty and Warranty Conditions

Warranty and Post-Warranty Service

EU Declaration of Conformity

Subject of declaration - model, product identification: Extol® Craft 414122; Submersible Waste Water Pump

Manufacturer: Madal Bal a.s., Bartošova 40/3, CZ-760 01 Zlín • Corp. ID No.: 49433717

Hereby declares that the product described above is in conformity with relevant harmonisation legal regulations of the European Union: 2006/42 ES; (EU) 2011/65; (EU) 2014/30. This declaration is issued under the exclusive responsibility of the manufacturer.

Harmonisation norms used: EN 60335-1:2012; EN IEC 60335-2-41:2021; EN ISO 12100:2010; EN IEC 55014-1:2021; EN IEC 55014-2:2021; EN 62233:2008; EN IEC 61000-3-2:2019; EN 61000-3-3:2013; EN IEC 63000:2018

Technical documentation compiled by: Martin Šenkýř, Madal Bal a.s., Průmyslová zóna Příluky 244, 76001 Zlín, Czech Republic.

Place and date of issue of EU Declaration of Conformity: Zlín, 21.08.2021

On behalf of Madal Bal, a.s.:

Martin Šenkýř, Member of the Company's Board of Directors

Models: 414122, 414122 Submersible Sewage Pump, 414122, Submersible Sewage Pump, Sewage Pump, Pump

File Info : application/pdf, 26 Pages, 2.98MB

PDF preview unavailable. Download the PDF instead.

414122 }

References

Adobe InDesign CS6 (Windows) Adobe PDF Library 10.0.1

Related Documents

Preview EXTOL CRAFT Submersible Dirty Water Pump Manual
This document provides comprehensive instructions and safety guidelines for the EXTOL CRAFT submersible dirty water pumps, including models 414123, 414142, and 414162. It covers product features, technical specifications, preparation for use, operation, maintenance, and disposal.
Preview Extol Craft Pressure Sprayer Manual: Safety, Operation, and Preparation
A comprehensive guide for Extol Craft pressure sprayers (models 92602, 92603), detailing safe operation, preparation of spray agents, and essential maintenance. This document consolidates information from English, Czech, Slovak, Hungarian, and German versions.
Preview EXTOL CRAFT 3915 Hand Mitre Saw - User Manual and Specifications
Detailed user manual and technical specifications for the EXTOL CRAFT 3915 Hand Mitre Saw, covering its use, assembly, technical data, and safety instructions.
Preview Extol Craft 417440 Digital Moisture Meter for Wood and Building Materials
User manual for the Extol Craft 417440 digital moisture meter. This device measures the moisture content of wood, paper, cardboard, mortar, concrete, and plaster. It also measures ambient temperature. The manual provides specifications, operating instructions, and disposal information.
Preview Extol Craft Cordless Wheelbarrow 402600 - User Manual, Assembly, and Safety Instructions
This comprehensive user manual provides detailed instructions for the Extol Craft Cordless Wheelbarrow 402600. It covers assembly steps, operation, safety guidelines, technical specifications, maintenance, and troubleshooting for efficient material transport in demanding terrain.