F-410 Flow Meter
Operating Manual
Introduction
Congratulations on purchasing the F-410 Flow Meter! Your Flow Meter is calibrated and ready for use. The unit is designed to provide many years of service. For more information or questions on this product or any other Blue-White Industrial products, please visit www.blue-white.com.
What's in the box
- Flow meter (1) (May contain plastic tubing for protection during shipping; remove before installation.)
- Quick Start Guide
Check all packaging for completeness and inspect for damage before installation.
System Features
- Dual Scale (GPM / LPM), screen printed with white backing on the opposite side for easy reading.
- Tested and calibrated for clean water applications.
- Acceptable for outdoor installations.
- One-piece machined acrylic meter body.
- Threaded adapters for simple installation on piping.
- Unique O-ring design prevents leaks.
- Upward flow, vertical installation only.
Application Notes
While meters may be suitable for other chemicals, Blue-White cannot guarantee their suitability. It is the responsibility of the user to determine the suitability of the flow meter in their application. Flow meters are tested and calibrated for water only.
Ordering Information / Model Number Matrix
The F-410 Model Number is constructed as follows:
F (Flow Meter) - 40750 (1-10 gpm / 4-38 lpm, 316SS Float) or 41000 (2-20 gpm / 8-80 lpm, 316SS Float) - LN (316 Stainless steel rod Guide-Wire Material) - 12 (.75" Female NPT, Polypropylene Adapter) or 16 (1.0" Female NPT, Polypropylene Adapter) - (Blank) (Viton O-Rings) or -22P (EP O-Rings).
Example Model Number: F-40750LN-12
Note: In-house NIST Calibration, silicone oil-free, and bulk packaging options are also available.
Engineering Specifications
Flow Meter Specifications
Specification | Value |
---|---|
Maximum Working Pressure | 150 PSI (10.3 bar) at 70 °F (21 °C) |
Maximum Fluid Temperature Range | 150 °F / 88 °C @ 0 PSI |
Ambient Temp Range | 0° to 110 °F / -18 to 43 °C |
Full Scale Accuracy | +/- 5% |
Calibration Fluid | Water, specific gravity 1.0 |
Environment | Acceptable for direct sunlight exposure |
Approximate Shipping Weight | 2 lb (.91kg) |
Materials of Construction
Component | Material |
---|---|
Wetted Components: Meter Body | Cast acrylic rod, Annealed |
Adapters | Polypropylene |
O-ring Seals | Viton® (optional EP) |
Float | 316SS |
Guide Rod | 316SS |
Temperature vs. Pressure Graph
The 'Maximum Temperature vs. Pressure' graph illustrates the relationship between static pressure and the maximum allowable fluid temperature. It shows a downward trend, indicating that as pressure increases, the maximum safe operating temperature decreases. Specifically, at 0 PSI (0 bar), the maximum temperature is 150°F (88°C), while at 150 PSI (10 bar), it drops to 70°F (21°C).
Flow Specifications
Output Specifications:
Model | Dual Scale Range (GPM / LPM) | Adapter F/NPT | Adapter Material | Float Material |
---|---|---|---|---|
F-40750LN-12 | 1 to 10 / 4 to 38 | 3/4" | Polypropylene | 316SS |
F-40750LN-16 | 1 to 10 / 4 to 38 | 1" | Polypropylene | 316SS |
F-41000LN-12 | 2 to 20 / 8 to 80 | 3/4" | Polypropylene | 316SS |
F-41000LN-16 | 2 to 20 / 8 to 80 | 1" | Polypropylene | 316SS |
Dimensions
The diagram shows the flow meter with two key dimensions labeled: 'A' measuring 11 inches (27.9 cm) and 'B' measuring 1-3/4 inches (4.4 cm).
Installation
Installation Requirements
Before beginning installation, review your system flow and pressure to ensure your F-410 is proper for your system parameters.
Pipe Requirements:
- The flow meter is designed to work best when installed in a perfectly vertical pipe system.
- Ensure piping design prevents any stress on the meter fittings, minimizes vibration, and ensures location with direct visibility and minimal possibility of damage from forcible contact.
- Pipe should be clean and free of debris.
- Connecting pipe should be uniform and not warped.
- Pipe must be properly supported even during maximum water flow conditions.
- Use of unionized fittings before and after the flow meter will allow for easier installation and removal for maintenance.
- On/Off solenoid valves and pumps installed before the flow meter should be accompanied by flow regulating/throttling valves, or similar device, to prevent sudden and forcible flows through the flow meter, which can cause damage to flow meter components.
- Choose a location where the pipe will be full at all times.
Tools Required
- PTFE Tape
- Level
Note: Keep flow meter away from pipe glue fumes. Ensure all pipe glue is dry before installing the flow meter. Pipe glue solvents will damage acrylic.
Installation Instructions
Safety Warning: Always wear protective clothing, face shield, safety glasses, and gloves when working on your equipment. Use caution when lifting and mounting equipment. When in doubt, contact the factory for assistance.
- The flow meter must be installed in a vertical plane to ensure accuracy. Prepare piping and components per standard piping installation.
- Use only PTFE tape on the threaded adapters. Pipe dope and glue will damage the meter body and fittings. Alternatively, install the flow meter after all glued fittings have dried and fumes have been purged from the system.
- Mounts and supports must be sturdy enough to support the plumbing and prevent vibration. Vibration and heavy loads will damage the meter.
- Avoid imposing a sudden burst of flow to the meter. Solenoid valves can cause such bursts, which will impact the float against the top float stop with destructive force.
- The maximum fluid temperature is dependent on the working pressure. High pressure and temperature will damage the meter (refer to the temperature vs. pressure chart).
Reading your F-410 Flow Meter
Avoid imposing a sudden burst of flow to the meter. Solenoid valves may cause the float to impact the top float stop with destructive force. Always read the float at its top position.
Illustrations show different types of floats used in flow meters.
Maintenance and Troubleshooting
The F-410 Flow Meter requires very little maintenance. However, the flow meter may become clogged due to excess debris in the water. If this happens, simply shut off the process pump or valve and remove any pressure from the piping. If isolation valves are installed, shut these to minimize water leakage. Locate the nearest unions on the piping to allow for removal of the flow meter. Remove the flow meter and clean any debris using mild soap and a soft bristle brush.
Reinstall the flow meter and test. If the float was removed during the cleaning process, ensure the float was reinstalled properly. The float is wider at the top.
If the flow meter requires NIST Calibration Certification, please contact the factory for this service.
Spare Parts
F-410 Replacement Parts
Item | Model No. | Product Name | Qty. Req. |
---|---|---|---|
1 | F-4009N | 3/4" FPT Adapter (PP)* | 2 |
F-4011 | 1" FPT Adapter (PP)* | 2 | |
2 | 90003-671 | O-ring, 217 (Viton)* | 2 |
90003-670 | O-ring, 217 (EP - Blue)* | 2 | |
3 | F-4013PP | Wire holder (PP) | 2 |
4 | - | Float (SS) (contact factory) | 1 |
5 | F-4012 | Guide Wire (SS) | 1 |
6 | - | Meterbody (Acrylic) (contact factory) | 1 |
* Contact factory for assistance on flow meters purchased prior to 7/10/2024, which use adapter and O-rings with different tolerances.
The exploded view diagram shows the components of the F-410 Flow Meter, including adapters, O-rings, wire holder, float, guide wire, and meter body, corresponding to the spare parts list.
Warranty
Limited Warranty
Your new Flow Meter is a quality product and is warrantied for 12 months from the date of purchase (proof of purchase is required). The unit will be repaired or replaced at Blue-White's discretion. Failure must have occurred due to a defect in material or workmanship and not as a result of operation of the product other than in normal operation as defined in the manual. Warranty status is determined by the serial label and the sales invoice or receipt. The serial label must be on the unit and legible. The warranty status of the unit will be verified by Blue-White or a factory-authorized service center.
What is Not Covered
- Wear items.
- Unit removal or re-installation, and any related labor charge.
- Freight to the factory or service center.
- Units that have been tampered with, or are in pieces.
- Damage to the unit resulting from misuse, carelessness (such as chemical spills on the enclosure), abuse, lack of maintenance, or alteration which is out of Blue-White's control.
- Units damaged by faulty wiring, power surges, or acts of nature.
Procedure for In-Warranty Repair
Contact the factory to obtain an RMA (Return Material Authorization) number. Carefully pack the unit to be repaired. Please enclose a brief description of the problem, along with the original invoice or sales receipt, or a copy showing the date of purchase. Prepay all shipping costs. COD shipments will not be accepted. Warranty service must be performed by the factory or an authorized service center. Damage caused by improper packaging is the responsibility of the sender. When in-warranty repair or replacement is completed, the factory pays for return shipping to the dealer or customer.
Product Use Warning
Blue-White products are manufactured to meet the highest quality standards. Each product instruction manual includes a description of the associated product warranty and provides important safety information. Purchasers, installers, and operators of Blue-White products should take the time to inform themselves about the safe operation of these products. Customers are expected to perform their own due diligence regarding which products and materials are best suited for their intended applications. Blue-White is pleased to assist in this effort but does not guarantee the suitability of any particular product for any specific application, as Blue-White does not have the same degree of familiarity with the application as the customer/end user. While Blue-White will honor all of its product warranties according to their terms and conditions, Blue-White shall only be obligated to repair or replace its defective parts or products in accordance with the associated product warranties. BLUE-WHITE SHALL NOT BE LIABLE EITHER IN TORT OR IN CONTRACT FOR ANY LOSS OR DAMAGE, WHETHER DIRECT, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL, ARISING OUT OF OR RELATED TO THE FAILURE OF ANY OF ITS PARTS OR PRODUCTS OR OF THEIR NONSUITABILITY FOR A GIVEN PURPOSE OR APPLICATION.
Chemical Resistance Warning
Blue-White offers a wide variety of wetted parts. Purchasers, installers, and operators of Blue-White products must be well-informed and aware of the precautions to be taken when injecting or measuring various chemicals, especially those considered to be irritants, contaminants, or hazardous. Customers are expected to perform their own due diligence regarding which products and materials are best suited for their applications, particularly concerning the potential effects of certain chemicals on Blue-White products and the potential for adverse chemical interactions. Blue-White tests its products with water only. The chemical resistance information included in this instruction manual was supplied to Blue-White by reputable sources, but Blue-White is not able to vouch for the accuracy or completeness thereof. While Blue-White will honor all of its product warranties according to their terms and conditions, Blue-White shall only be obligated to repair or replace its defective parts or products in accordance with the associated product warranties. BLUE-WHITE SHALL NOT BE LIABLE EITHER IN TORT OR IN CONTRACT FOR ANY LOSS OR DAMAGE, WHETHER DIRECT, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL, ARISING OUT OF OR RELATED TO THE USE OF CHEMICALS IN CONNECTION WITH ANY BLUE-WHITE PRODUCTS.
Contact Information
? Phone: +1 (714) 893 - 8529
✉️ Email: sales@blue-white.com
✉️ Customer Service: customerservice@blue-white.com
? Address: 5300 Business Drive, Huntington Beach, CA 92649
Website: www.blue-white.com
P.N. 80000-611 F-410 Flow Meter REV 3 20240722
ISO 9001:2015 CERTIFIED | MADE IN THE USA
Users of electrical and electronic equipment (EEE) with the WEEE marking per Annex IV of the WEEE Directive must not dispose of end-of-life EEE as unsorted municipal waste, but use the collection framework available to them for the return, recycle, recovery of WEEE and minimize any potential effects of EEE on the environment and human health due to the presence of hazardous substances. The WEEE marking applies only to countries within the European Union (EU) and Norway. Appliances are labeled in accordance with European Directive 2002/96/EC.
Contact your local waste recovery agency for a Designated Collection Facility in your area.
File Info : application/pdf, 12 Pages, 1.38MB
DocumentDocumentReferences
Adobe PDF Library 17.0 Adobe InDesign 19.5 (Windows)Related Documents
![]() |
Blue-White F-400 Series In-Line Flowmeter: Installation, Specifications, and Warranty Comprehensive guide for the Blue-White F-400 Series In-Line Flowmeter, covering installation procedures, technical specifications, parts list, maintenance, and limited warranty information. |
![]() |
Blue-White F-400 Flow Meter Operating Manual Official operating manual for the Blue-White F-400 Flow Meter, providing detailed information on installation, specifications, materials, maintenance, troubleshooting, and warranty. |
![]() |
Blue-White F-1000 Flow Meter Instruction Manual Comprehensive instruction manual for the Blue-White F-1000 series electronic flow meters, covering installation, operation, maintenance, and troubleshooting for models F-1000-RB, F-1000-TB, and F-1000-RT. |
![]() |
Blue-White F-2000 Flow Meter Instruction Manual Comprehensive instruction manual for the Blue-White F-2000 electronic flow meter, covering installation, operation, features, specifications, and maintenance. |
![]() |
Blue-White ProSeries SONIC-PRO™ S2x Hybrid Ultrasonic Flowmeter Technical Data Technical data and specifications for the Blue-White ProSeries SONIC-PRO™ S2x Hybrid Ultrasonic Flowmeter, detailing its features, applications, installation, and performance. |
![]() |
Blue-White F-420 In-Line Flowmeter: Instruction Manual & Installation Guide Comprehensive instruction manual and installation guide for the Blue-White F-420 Series In-Line Flowmeter. Includes specifications, parts list, maintenance, and warranty information. |
![]() |
FLEXFLO® A-100NF & A100NV Peristaltic Metering Pump Operating Manual This operating manual provides comprehensive guidance for the Blue-White FLEXFLO® A-100NF and A100NV Peristaltic Metering Pumps, detailing installation, operation, maintenance, and troubleshooting for precise chemical injection in various piping systems. |
![]() |
Blue-White FlexFlo Peristaltic Metering Pump M-3 and M-4 Operating and Maintenance Manual This manual provides operating and maintenance instructions for the Blue-White FlexFlo M-3 and M-4 Peristaltic Metering Pumps. It covers installation, operation, maintenance, specifications, and troubleshooting. |