INKBIRD IHC-200-WIFI Humidity Controller

Smart Home | Smart Life

Introduction

The INKBIRD IHC-200-WIFI is a smart humidity controller designed for precise environmental management. The device features two display screens: PV (Present Value) showing the current humidity and SV (Set Value) showing the target humidity or menu code. It includes indicator lights and two output sockets for controlling humidification and dehumidification devices.

The front panel displays the current humidity (PV) and set humidity (SV) in %RH. It features a SET button, a WIFI button, an Increase button (⬆️), and a Decrease button (⬇️). WORK1 is the Humidification Output Socket, and WORK2 is the Dehumidification Output Socket. The device supports various socket types including US, EU, UK, and AU.

Product Features

Specifications

Wi-Fi Connection

4.1 Download Inkbird Smart App

To connect your device to Wi-Fi, first download the "InkbirdSmart" app. Search for it in the Appstore or Google Play. A QR code is also provided for direct download (QR code excluded).

4.2 Connect to your phone

Follow these steps to connect your device to your home Wi-Fi network:

  1. Register: Open the InkbirdSmart app and select your Country/Region. Enter your phone number or email address, then enter the verification code sent to you to confirm your identity and complete registration.
  2. Add Home: Press the "Add Home" button to create a virtual home environment within the app.
  3. Add Device: On the app's home page, tap the "+" or "add device" button.
  4. Reset Wi-Fi: When the controller is in its normal working state, press and hold the WIFI button for 2 seconds. The controller will enter Smartconfig configuration mode by default. You can short press the WIFI button to switch between Smartconfig mode and AP mode. The Wi-Fi module requires approximately 5 seconds for data processing, after which the corresponding LED symbol and state will update.

4.3 Quick Connection (Smartconfig Mode)

Ensure the device is in Smartconfig state, indicated by the LED symbol flashing rapidly with a 250ms interval. On your app, check for the blinking LED confirmation, then enter your Wi-Fi password to connect to your wireless network. Click "Confirm" to complete the connection.

Note: The device only supports 2.4GHz Wi-Fi routers.

4.4 Connect the device in AP mode

Ensure the device is in AP Configuration State, indicated by the LED symbol flashing slowly with a 1500ms interval. On the app, click "Confirm indicator slowly blink". Select your Wi-Fi network, enter the password, and click "Confirm" to initiate the connection process.

Press "Connect now" on the app. This will direct you to your smartphone's WLAN Settings interface. Select the "SmartLife-XXXX" network to connect directly to the router without needing a password. Return to the app to enter the automatic connection interface.

After the device is successfully added, click "Done" to enter the device controlling interface. In the temperature control mode, users can configure various control functions via the app.

4.5 Wi-Fi State

Settings

5.1 Key Setting

5.1.1 Factory Reset

To restore all parameters to factory settings, hold the ⬇️ button and turn on the device. A short buzzer beep will confirm the reset.

5.1.2 Fast Setting

Press the SET button lightly to enter quick set-up mode. The SV screen will display the current setting value and flash. Use the ⬆️ or ⬇️ buttons to change the value (hold for rapid adjustment). Press the SET button again to save settings and exit the setting mode. The controller will also automatically save settings and exit if there is no operation for 10 seconds.

5.1.3 Normal Setting

To enter setting mode while the controller is operating normally, hold the SET button for 2 seconds. The PV screen will display "HS" (the first menu item), and the SV screen will show the corresponding setting value. Press the SET button to switch between menu items. Use the ⬆️ or ⬇️ buttons to change the value. The value is saved automatically when you switch to another menu item by pressing SET.

Press and hold the SET button for 2 seconds to save settings and exit the setting mode. The controller will also exit setting mode and return to normal working mode if there is no operation for 30 seconds.

5.2 Flowchart of the Settings

The settings flowchart illustrates the parameter adjustment process:

Basic Operations

6.1 Instructions for Humidity Control Setting (HS, HD, DD)

When operating normally, the PV screen displays the current humidity. The device automatically recognizes and switches between humidification and dehumidification modes based on the following logic:

Example: Let HS = 50.0%RH, HD = 5.0%RH, and DD = 8.0%RH.

Note: The differential values for humidification or dehumidification are not evaluated when the device is powered on or exiting the setting state. For instance, upon startup with HS = 50.0%RH, if the measured humidity (PV) is greater than 50.0%RH, it will enter the dehumidification state. If PV is less than or equal to 50.0%RH, dehumidification will stop, returning to normal humidity control mode.

6.2 High/Low Humidity Alarm (AH, AL)

The equipment will trigger an alarm if the measured humidity (PV) is greater than or equal to the set value for the high humidity alarm (AH). The PV screen will alternate between displaying the AH set value and the current humidity. A buzzer will sound "bi-bi-Biii" until the measured humidity (PV) drops below the AH set value. The alarm can be silenced by pressing any button on the equipment.

Similarly, the equipment will alarm if the measured humidity (PV) is less than or equal to the set value for the low humidity alarm (AL). The PV screen will alternate between displaying the AL set value and the current humidity. The buzzer will sound "bi-bi-Biii" until the measured humidity (PV) rises above the AL set value. This alarm can also be silenced by pressing any button.

Note: The setting value for the low humidity alarm (AL) should always be less than the setting value for the high humidity alarm (AH).

6.3 Dehumidification Delay Time (PT)

In dehumidification mode, the equipment may not start immediately on the first instance if the measured value is larger than the sum of the set humidity value and the dehumidification return difference. It will commence dehumidification only after the set delay time has elapsed. If the time interval between two consecutive dehumidification cycles is longer than the set delay time, dehumidification will start immediately. If the interval is shorter, it will start after the delay time. The delay timer begins when the last dehumidification cycle is completed. Note: The delay time is not evaluated upon power-on or when exiting the setting state.

6.4 Humidity Calibration (CA)

If the measured humidity deviates from the standard humidity, you can calibrate the device. This is done by adjusting a correction value to align the measured humidity with the standard humidity. The calibrated humidity is calculated as: Calibrated Humidity = Measured Humidity Value + Calibration Value.

Sensor Fault Alarm

If the humidity sensor experiences a short circuit or open circuit, the controller will enter probe fault mode and cease operation. The buzzer will sound, and the screen will display "ER". Pressing any key will stop the buzzer, and the controller will return to normal working state once all malfunctions are resolved.

Important Safeguards

It is crucial to exercise caution when using electrical appliances. Please adhere to the following safety guidelines:

Warranty

This Limited Warranty exclusively applies to the Inkbird IHC-200-WIFI Humidity Controller.

What is Covered and for How Long

Inkbird guarantees that all new products are free from defects in manufacturing, materials, and workmanship for a period of one year from the original date of retail purchase.

What this Warranty Does not Cover

This warranty does not cover defects or malfunctions resulting from misuse, abuse, improper maintenance, failure to follow operating instructions, or use with equipment for which the product is not intended. Furthermore, the warranty will not apply to damage caused by unauthorized alteration, modification, or repair of the product. Inkbird does not provide warranty or service support for any third-party products, including but not limited to iPhones and Android Phones.

How to Obtain Warranty Service

To obtain warranty service for products purchased from a third-party retailer or directly from Inkbird, you must return the product along with proof of purchase, following these procedures:

Exclusions and Limitations

This warranty represents your exclusive remedy and supersedes all other warranties or conditions, whether express or implied, including any implied warranties or conditions of merchantability or fitness for a particular purpose. In jurisdictions where the exclusion of express or implied warranties is not permitted, the above exclusion may not apply to you. In such cases, any applicable warranties will extend only to the extent and duration required by law and will be limited to the warranty period. If certain states or jurisdictions do not allow limitations on the duration of an implied warranty, the above limitation on duration may not apply to you.

PDF preview unavailable. Download the PDF instead.

D1Nsq2uehKS Adobe PDF library 15.00 Adobe Illustrator CC 23.0 (Windows)

Related Documents

Preview INKBIRD IHC-200-WIFI Humidity Controller User Manual
Detailed user manual for the INKBIRD IHC-200-WIFI Humidity Controller, covering features, specifications, Wi-Fi setup, settings, operations, alarms, safeguards, and warranty information.
Preview INKBIRD IHC-200-WIFI Humidity Controller User Manual
Comprehensive user manual for the INKBIRD IHC-200-WIFI Humidity Controller, detailing product features, technical specifications, Wi-Fi connectivity setup, operational settings, basic functions, alarm systems, safety precautions, and warranty information.
Preview INKBIRD IHC-200-WIFI Humidity Controller User Manual
Comprehensive user manual for the INKBIRD IHC-200-WIFI Humidity Controller, covering features, specifications, Wi-Fi setup, settings, operations, safeguards, and warranty information.
Preview Inkbird IHC-200-WIFI Humidity Controller User Manual
This user manual provides comprehensive instructions for the Inkbird IHC-200-WIFI Humidity Controller, covering its features, specifications, Wi-Fi setup, operation, and safety guidelines.
Preview Inkbird IHC-200-WIFI Humidity Controller User Manual
Comprehensive user manual for the Inkbird IHC-200-WIFI Humidity Controller, covering product features, technical specifications, Wi-Fi setup, operational guidance, and warranty information for smart home environments.
Preview INKBIRD IHC-200-WIFI Humidity Controller User Manual
User manual for the INKBIRD IHC-200-WIFI Humidity Controller, covering product features, specifications, Wi-Fi connection, settings, basic operations, troubleshooting, and warranty information.
Preview INKBIRD IHC-200 Plug and Play Humidity Controller User Manual
Detailed user manual for the INKBIRD IHC-200 Plug and Play Humidity Controller, covering specifications, operation, settings, error codes, and warranty information.
Preview IHC-200 WIFI Humidity Controller FCC/IC Test Report - Shenzhen Inkbird Technology Co.,Ltd
Official test report for the Shenzhen Inkbird Technology Co.,Ltd IHC-200 WIFI Humidity Controller (FCC ID: 2AYZD-200WIFI, IC: 30368-200), detailing conducted and radiated emissions, RF bandwidth, and power spectral density test results.