AUTOPHIX V007 Software Update Guide
Upgrade Process for AUTOPHIX V007
This guide details the steps required to update the software for your AUTOPHIX V007 diagnostic tool.
Step 1: Connect Device to PC
Connect your AUTOPHIX V007 device to your computer using a USB cable.
[Diagram: AUTOPHIX V007 device connected to a laptop via USB cable.]
Step 2: Install Drivers and Open Software
Launch the VAG007 PC Tool software on your computer.
[Screenshot: Windows File Explorer window showing the VAG007 PC Tool software files.]
Install the necessary device drivers. Follow the on-screen prompts, clicking "OK" to complete the driver installation.
[Screenshot: Device Driver installation dialog and success message.]
Step 3: Identify and Select COM Port
Reopen the upgrade software. To ensure correct communication, identify the assigned COM port number for your device. This can be found in your PC's Device Manager, typically under 'Ports (COM & LPT)' as 'USB-SERIAL CH340 (COMx)'.
[Screenshot: Windows Device Manager showing the detected USB serial port (e.g., COM4).]
In the upgrade software, select the correct COM port from the dropdown menu.
[Screenshot: Upgrade software interface with a COM port selection dropdown.]
Step 4: Load the First Upgrade File
Click the "Main File" button. Navigate to and select the FlashFile_V2.6.BIN
file, then click "Open".
[Screenshot: 'Open a binary file' dialog box, with 'FlashFile_V2.6.BIN' selected.]
Step 5: Perform Initial Update
Click "Open Port" to establish a connection. Then, click "Main Update" to begin the first phase of the upgrade.
[Screenshot: VAG007 Upgrade PC Tool interface showing the progress bar and update controls.]
Upon successful completion, you will see an "Update Successful!" message. Disconnect the USB cable once the device's main interface is visible again.
[Screenshot: VAG007 Upgrade PC Tool interface displaying 'Update Successful!' message.]
Troubleshooting: If the COM port is not detected, verify the USB connection and restart the software.
Step 6: Load and Perform Second Upgrade
Reconnect the data line. Click "Close String" and then "Open String" again.
Click the "FLASH File" button. In the dialog that appears, select the MainFile_V6.4.BIN
file and click "Open".
[Screenshot: 'Open a binary file' dialog box, with 'MainFile_V6.4.bin' selected.]
Click "FLASH upgrade" to start the second upgrade process. This step may take longer; please be patient.
[Screenshot: VAG007 Upgrade PC Tool interface showing the progress bar during the FLASH upgrade.]
Once this upgrade is complete, the device will show its boot interface, indicating it is ready for use.
[Screenshot: VAG007 Upgrade PC Tool interface displaying 'Update Successful!' after the FLASH upgrade.]
Important Note: For comprehensive details, consult the full upgrade instructions. If an upgrade fails, do not worry; simply repeat the upgrade steps. This will not impact the device's normal functionality.