ASW H-T3 Series
Three phase hybrid inverters 8 to 12 kW
Key Features
Easy-to-install [wrench]
- Quick and easy-to-install with standard tools
- Compact wall mount design
- Simple battery and smart meter interfaces for quick and secure installation
Safe & reliable [shield]
- Up to 150 % PV array oversizing for higher yields
- Available with or without asymmetrical power output 1
- UPS level switching time < 10 ms
- IP66 rated design for indoor and outdoor use
- Arc fault circuit interrupter (AFCI) 2
- ShadeSol shadow management
User-friendly [smartphone]
- 3 independent MPPTs for flexible and higher kWp PV array design
- Smart setup, commissioning and monitoring via Solplanet App
- Intelligent operation modes and smart battery management for DOD / Time of Use / Power setting
- Max. 16 A input current, ideal for bifacial and large PV modules
- Supporting parallel for on-grid and off-grid operation
Models
- ASW08kH-T3
- ASW10kH-T3
- ASW12kH-T3
Technical Datasheet
Parameter | ASW08kH-T3 | ASW10kH-T3 | ASW12kH-T3 |
---|---|---|---|
PV input | |||
Max. PV array power | 12000 Wp | 15000 Wp | 18000 Wp |
Max. input voltage | 1100 V 5 | ||
MPP voltage range / rated input voltage | 200 V to 950 V / 630 V 3 | ||
Min. input voltage / start voltage | 60 V / 180 V | ||
No. of independent MPPT trackers / strings per MPPT input | 3 / 1 | ||
Max. input current / Max. power per MPP tracker | 16 A | 10000 W | 16 A |
Max. short-circuit current per MPP tracker | 16 A | 10000 W | 16 A |
Battery input | |||
Battery voltage range | 120 V to 600 V 5 | ||
Max. charging / discharging power | 8000 W | 10000 W | 12000 W |
Max. charging current / Max. discharging current | 30 A 5 | ||
Battery type | LiFePO4 | ||
AC input | |||
Rated grid voltage | 3/N/PE, 220/380 V; 230/400 V; 240/415 V | ||
Rated grid frequency | 50 Hz / 60 Hz | ||
Max. input power from grid | 16000 W | 20000 W | 24000 W |
Max. input current from grid | 23.2 A | 29.0 A | 34.8 A |
AC voltage range / Nominal AC voltage | 270V to 480V / 3/N/PE, 220 V / 380 V; 230 V / 400 V; 240 V / 415 V | ||
Rated AC grid frequency | 50 Hz / 60 Hz | ||
AC grid frequency range | 45 ~ 55 Hz / 55 ~ 65 Hz | ||
AC output | |||
Rated apparent power | 8000 VA | 10000 VA | 12000 VA |
Max. apparent power | 8000 VA | 10000 VA | 12000 VA |
Rated grid output current (@400 V) | 11.6 A | 14.5 A | 17.4 A |
Max. grid output current(@400 V) | 12.8 A | 16.0 A | 19.2 A |
Power factor at rated power / adjustable displacement | 1 / 0.8 leading to 0.8 lagging | ||
Harmonics THDi (@ Nominal power) | < 3 % (of nominal power) | ||
EPS output | |||
Nominal output voltage | 3/N/PE, 220 V / 380 V; 230 V / 400 V; 240 V / 415 V | ||
Nominal output frequency | 50 Hz / 60 Hz | ||
Rated apparent power | 8000 VA | 10000 VA | 12000 VA |
Rated current (@400 V) | 11.6 A | 14.5 A | 17.4 A |
Max. current (@400 V, continuous on-grid / off-grid) | 23.2 A / 11.6 A | 29.0 A / 14.5 A | 34.8 A / 17.4 A |
Max. power on each phase (@400 V, continuous on-grid / off-grid) | 5333 W / 2667 W | 6667 W / 3333 W | 8000 W / 4000 W |
Peak output apparent power (@400 V, continuous on-grid / off-grid up to 10s) | 16000 VA / 16000 VA | 20000 VA / 20000 VA | 24000 VA / 24000 VA |
Max. switch time | < 10 ms | ||
Output THDv (@ Linear load) | 2 % | ||
Effi- ciency | |||
MPPT efficiency | 99.9 % | ||
Euro efficiency / Max. efficiency | 97.2 % / 98.0 % | 97.9 % / 98.4 % | |
Safety protection | |||
DC surge protection (Type II, according to EN/IEC 61643-11) | • | • | • |
Insulation resistance detection | • | • | • |
PV string input reverse polarity protection | • | • | • |
Battery input reverse polarity protection | • | • | • |
Ground fault monitoring | • | • | • |
Residual current monitoring unit | • | • | • |
AC short circuit protection | • | • | • |
Anti-islanding protection | • | • | • |
Arc fault circuit interrupter (AFCI) | • | • | • |
General data | |||
Dimensions (W / H / D) | 545 / 465 / 205 mm | ||
Weight | 26 kg | ||
Operating temperature range | -25 °C ... +60 °C | ||
Cooling concept | Natural convection | ||
Noise emission | < 35 dB | ||
Degree of protection (as per IEC 60529) | IP66 | ||
Max. relative humidity | 100 % | ||
Max. operating altitude | 4000 m | ||
User interface | LED & App | ||
BMS interface | CAN | ||
Smart meter interface | RS485 | ||
Communication interfaces | Dongle: WiFi (2.4 GHz) / LAN (100 Mbps) Inverter: RS485 (ModBus RTU), LAN (100 Mbps, Modbus TCP only) 4 | ||
Features | |||
Digital output (dry contact) / No. of outputs | / 2 | ||
Digital input (dry contact) / No. of inputs | / 4 | ||
Integrated power control / export power control | / |
Notes:
1 Asymmetrical power output functionality released in August 2024, please confirm version with Solplanet's sales staff before purchase.
2 AFCI functionality released in April 2025, please confirm version with Solplanet's sales staff before purchase.
3 The latest optimised platform design supports MPP voltage range at 150V-950V, pending subsequent certificate updates.
4 Modbus TCP functionality released in April 2025, please confirm version with Solplanet's sales staff before purchase.
5 When connecting to Solplanet's high voltage batteries (with only 5 kWh, i.e. two modules), limitations as below apply:
- The maximum voltage of PV shall not exceed 750V
- The battery voltage range is reduced to 102.4 V for the particular operation
- The maximum charging and discharging current depends on the operating point and is within the range greater than 25A, less than 30A