Hunter Ontario 6-Light Pendant

Installation Instructions

Preparing for Installation

Carefully remove all contents from the carton. Shut off the power at the circuit breaker and completely remove the old fixture from the ceiling, including the old mounting bracket. Remove the new mounting bracket assembly from the bag. One end of the threaded post (F) should be attached to the mounting bracket (A) with a washer (D) and a hex nut (E) in place. The other end should have the canopy loop (G) attached. Unscrew the canopy loop ring (I) from the canopy loop (G). Depending on the placement of your junction box, the position of the threaded post (F) may need to be adjusted to allow the canopy (H) to be flush with the ceiling. Determine this by lifting mounting bracket (A) up to the junction box and placing canopy (H) over the canopy loop (G), so that it is flush with the ceiling. Adjust the position of threaded post (F) on the mounting bracket (A) so that the canopy (H) covers at least half of the exterior threads on the canopy loop (G) while it is securely connected to threaded post (F). The threaded post (F) can be adjusted by loosening hex nut (E) to allow movement of threaded post (F) on mounting bracket (A). Once the ideal position of the threaded post (F) is determined, tighten up the hex nut (E) onto the threaded post (F) just beneath the mounting bracket (A) to secure the threaded post in place.

Assembling the Fixture

Thread wires through center fixture stem (U) then screw into hex post (W) of the lower section of fixture and secure by tightening nut (V). Slide cover stem (T) over fixture stem (U). Place upper fixture ring (S) over center fixture stem (U) followed by washer (R) and secure with hex post (Q). Thread wires through center fixture stem (O), locking it in place by tightening lower nut (P). Slide cover stem (N) over fixture stem (O) and adjust upper nut (P) to be aligned with the top edge of cover stem (N). Thread wires through stem (M) of hanging ring (L) and tighten onto center stem (O). By measuring, determine the correct number of chain links needed for proper hanging height. If necessary, use a pair of pliers ? to open and remove any excess chain. Use one quick-connect link (J) to attach chain (K) to hanging ring (L) and securely close. Feed the fixture wires up through the chain (every three links or so), pulling the wires until taut. Slide canopy loop ring (I) and canopy (H) onto the chain/wire and thread wires through canopy loop (G). Use the remaining quick-connect link (J) to attach chain (K) to canopy loop (G). To shorten the fixture, trim the wires to desired length. Leave at least 8 to 10 inches of wire in addition to the desired length. Have a helper support the fixture's weight and attach the mounting bracket (A) to the junction box by securely tightening the mounting screws (B).

Connecting the Wires

Attach the fixture's wires to the power supply wires from the junction box. Connect black to black (live); white to white (neutral); grounding to grounding (green or copper). Twist the ends of the wire pairs together then twist on a wire connector. Make sure all twists are in the same direction. Loop fixture's ground wire around grounding screw (C) and tighten. If there is no ground wire (green or copper) from the junction box, contact a qualified electrician.

Diagram: Wire Connections

A diagram illustrates wire connections. Fixture wires (black/smooth, white/ribbed, bare copper/green) are shown connecting to house wires (black/live, white/grounded, green or copper/grounding) using wire connectors. The fixture's ground wire is looped around grounding screw (C).

Finishing the Installation

Place the canopy (H) flush to the ceiling and slide the canopy loop ring (I) up beneath the canopy. Tightly screw canopy loop ring (I) onto the canopy loop (G) to properly secure the canopy (H) in place. Install light bulb (not included) in accordance with the fixture's specifications. Do not exceed the recommended wattage. Locate the arrow sticker (Z) on each fixture ring (S). This indicates the starting point for installing the glass panels (Y). You may remove the sticker before you install the glass or return after all panels are installed to remove the sticker. Carefully hook each glass panel (Y) over each set of 2 hooks (X) and slide the panel flush against the fixture ring (S) to ensure panels are aligned. Your installation is now completed. Turn on the power and test the fixture.

Cleaning Tips

Treat the fixture gently! Regular cleaning will reduce the need for deep cleaning. For regular cleaning, turn off the light and wipe down the fixture with a clean lint-free cotton or microfiber cloth. Never spray cleaner directly onto the fixture.

Hunter Pro Tips

  • Let the tool do the work! Use chain pliers ? to easily open and close chain links to shorten your fixture.
  • Twist or tape wire ends together to make it easier to pass them through the downrods. Threaded post may also be removed for easier wire access.

Tools You'll Need

  • Ladder ?
  • Screwdriver ?
  • Pliers ?
  • Wire Strippers ⚡

Diagram: Tools

Illustrations of tools required for installation: a ladder, a screwdriver, pliers, and wire strippers.

Specifications

Product: 6 Light Pendant

Fixture weight ±2 lbs: 45.59 lbs (20.68 kg)

Hardware Service Kit

Part # / Pieza # / Pièce #Model / Modelo / ModèleFinish / Finish / Fini
KG2080189513143Matte Black / Negro Mate / Noir Mat
KG20801A5713144Luxe Gold / Oro de Lujo / Or Grand Luxe

Glass / Domo De Vidrio / Verre

Part # / Pieza # / Pièce #Model / Modelo / ModèleType / Tipo / Type
KG2410114713143Clear Glass / Vidrio Transparente / Verre Transparent
KG24101L5413144Amber Glass / Vidrio Ámbar / Verre Ambré

Parts Diagram

A diagram shows the assembly of the light fixture with labeled parts from A to W. A is the mounting bracket, B are mounting screws, C is the grounding screw, D is a washer, E is a hex nut, F is the threaded post, G is the canopy loop, H is the canopy, I is the canopy loop ring, J is a quick-connect link, K is the chain, L is the hanging ring, M is the stem, N is the cover stem, O is the center fixture stem, P is a nut, Q is a hex post, R is a washer, S is the fixture ring, T is the cover stem, U is the center fixture stem, V is a nut, W is a hex post. The diagram also shows light bulbs and glass shades.

Safety Warnings

⚠️ WARNING

  • To avoid possible electrical shock, before installing your light fixture, disconnect the power by turning off the circuit breakers to the outlet box associated with the wall switch location.
  • The lighting fixture must be grounded. If the ground wire for the installation site is not present, immediately STOP installation and consult a qualified electrician.
  • All wiring must be in accordance with national and local electrical codes ANSI/NFPA 70. If you are unfamiliar with wiring or in doubt, consult a qualified electrician.

⚠️ ADVERTENCIA

  • Para evitar una posible descarga eléctrica, antes de instalar su lámpara, desconecte la energía apagando los interruptores automáticos (breakers) que alimentan la caja de salida asociada con la ubicación del interruptor de pared.
  • La lámpara se debe conectar a tierra. Si el alambre de conexión a tierra no está presente en el sitio de la instalación, DETENGA inmediatamente la instalación y consulte con un electricista calificado.
  • Todo el cableado debe realizarse de acuerdo con los códigos eléctricos locales y nacionales ANSI/NFPA 70. Si no está familiarizado con el cableado, o si tiene duda, consulte a un electricista calificado.

⚠️ AVERTISSEMENT

  • Pour éviter tout choc électrique, avant d'installer le luminaire, coupez le courant en éteignant les disjoncteurs de la boîte électrique associée à l'interrupteur mural.
  • Le luminaire doit être mis à la terre. Si le fil de terre du lieu d'installation n'est pas présent, ARRETER immédiatement l'installation et consulter un électricien qualifié.
  • Tout le câblage doit être conforme aux codes électriques nationaux et locaux en vigueur et à la norme ANSI/NFPA 70. Si vous n'avez pas l'habitude de faire ce câblage ou en cas de doute, adressez-vous à un électricien qualifié.

READ AND SAVE THESE INSTRUCTIONS. These instructions are provided for your safety. It is very important that they are read carefully and completely before beginning installation of the lighting fixture.

LEA Y GUARDE ESTAS INSTRUCCIONES. Estas instrucciones se proporcionan para su seguridad. Es muy importante leerlas detenidamente y completamente antes de comenzar la instalación de la lámpara.

LISEZ ET CONSERVEZ CES INSTRUCTIONS. Ces instructions sont fournies pour votre sécurité. Il est très important de les lire attentivement dans leur intégralité avant d'entreprendre l'installation du luminaire.

Models: ML454, Ontario 6 Light Medium Chandelier Ceiling Light Fixture, Ontario 6, Light Medium Chandelier Ceiling Light Fixture, Chandelier Ceiling Light Fixture, Light Fixture, Fixture

PDF preview unavailable. Download the PDF instead.

ML454 https://imagemagick.org

Related Documents

Preview Hunter Merian 48140 6-Light Chandelier Installation Guide
Comprehensive installation instructions for the Hunter Merian 48140 6-Light Chandelier, covering preparation, assembly, wiring, and finishing steps in English, Spanish, and French.
Preview Hunter Zoanne 6-Light Chandelier Installation Guide (Models 19572, 19573)
Step-by-step instructions for installing the Hunter Zoanne 6-Light Chandelier. Includes preparation, assembly, wiring, finishing, and cleaning tips for models 19572 and 19573.
Preview Hunter Rafner 19451 Pendant Light Installation Guide and Manual
Step-by-step installation instructions for the Hunter Rafner 19451 pendant light. This guide covers preparation, assembly, wiring, finishing, and cleaning for models 19449, 19451, 19453, and 19455.
Preview Hunter Klein 1-Light Pendant Installation Guide
Detailed installation instructions for the Hunter Klein 1-Light Pendant light fixture, including preparation, assembly, wiring, and finishing steps. Covers models 19438 and 19439.
Preview Hunter Valdaz 48259 3-Light Pendant Installation Instructions
Detailed installation guide for the Hunter Valdaz 48259 3-light pendant light fixture, including preparation, assembly, wiring, and finishing steps. Ensure safe and correct installation.
Preview Hunter Xidane 5-Light Chandelier Installation Guide
Comprehensive installation instructions for the Hunter Xidane 5-Light Chandelier (models 19747, 19748). This guide covers preparation, fixture assembly, wiring connections, final installation steps, and cleaning tips, ensuring a safe and correct setup.
Preview Hunter Southcrest 4-Light Chandelier Installation Guide
Comprehensive instructions for installing the Hunter Southcrest 4-Light Chandelier, including preparation, assembly, wiring, and finishing steps. Covers models 19638 and 19639.
Preview Hunter River Mill 3-Light Chandelier Installation Guide (Models 19472, 19473)
Comprehensive installation instructions for the Hunter River Mill 3-Light Chandelier. Covers preparation, assembly, wiring, finishing, and cleaning tips for models 19472 and 19473.