V3-204 Bottler

Installation requirements and specifications

I. Installation Requirements

1. Water connection

The water supply requirements for Vivreau water dispensers are crucial to ensure proper operation and hygiene. Here are the key points:

2. Electrical connection

The power requirements for Vivreau water dispensers can vary depending on the specific model. However, here are some general guidelines based on the information available:

For precise power requirements, always refer to the identification label on the dispenser or the specific model's operating manual. This label will provide detailed information about the voltage, frequency, and power consumption needed for safe and efficient operation. All power supply connections must be within 2-4 feet (24-48 inches) of the water dispenser's final installation location.

3. Waste water connection (integrated)

The dripping water will be collected in the moveable drip tray, which is to be emptied once it is full. No waste water connection is needed.

4. CO2 (customer supplied)

Food Grade CO2 Supply Required. If connecting to a bulk or existing CO2 supply system, a CO2 line terminating with a 1/4" barbed shutoff valve must be available within 40" of the System installation location, 100psi minimum pressure.

5. Millwork

Diagram indicates millwork considerations with specific dimensions. Key dimensions shown are 2.75 inches and 1.96 inches, likely relating to pipe connections or clearances.

II. Ventilation options

Cut ventilation grills into the side of the cabinet. Ventilation grills are available on request as accessories. The cabinet may be ventilated in several different ways to prevent excessive heat build-up. The methods shown all take advantage of natural circulation by placing two grills or cut-outs; one near the base and the other at the top of the enclosure. Base/kitchen cabinet back panel should be removed for better ventilation.

Front Ventilation

Typical cut-out size must not be less than 12.0" wide x 2" deep (24 sq inch).

Side Ventilation

Cut ventilation grilles into the side of the cabinet. The grilles may be fitted on either side allowing the ventilation into a free and unobstructed area.

Base Ventilation

Cut ventilation grilles into the cabinet's base panel and base plinth. Top ventilation will also be required in either the side panels or a cut out in the top of the door.

Base Cut-Out

Ensure ventilation by removing a narrow section of the floor, immediately behind the door and trim with roll edging strip. Typical cut-out size must be not less than 12.0" wide x 2" deep (24 sq inch).

III. Arrangement

Components typically arranged for the system:

Diagram shows placement of these components. Key dimensions include a maximum height of 8.07 inches for component 'a', a distance of 14 inches between components, and 5-inch clearances.

IV. Dimensions

204 Bottler

Diagram illustrating the physical dimensions of the 204 Bottler. Key measurements are: Width 19 3/8 inches, Depth 14 5/8 inches, Height 12 3/4 inches (dispenser body) and 21 1/4 inches (overall height including taps).

V. Technical data

204 Countertop Bottler

Specification Value
Cooling capacity (gal/h) 21
Min. required space (W x H x D inch) 24 x 29.5 x 24
Dimensions (W x H x D inch) 14.6 x 21.2 x 19.3
Chiller filter dimensions (diam x H inch) 5 x 14
Bottler Weight 73 lbs
Chiller filter Weight 3 lbs
Chilled water flow rate (l/min) 2
Max. power consumption (W) 565
Drip tray Integrated
Water types Chilled still and chilled sparkling
Waste water connection Not required
Voltage (V) 110-120V
Frequency (Hz) 50
Max. current (A) 5.1
CO2 operating pressure (MPa / bar) 0.45-0.5
Max. inlet water pressure (MPa / bar) 0.25-0.4 / 2.5-4
Max. inlet water temperature (°C) 25
Max. humidity (%) 60
Refrigerant Type R134a
Refrigerant weight (kg) 0.095

Email: infousa@vivreau.com

Phone number: +1 877 999 1044

24/7 Product Assistant: vivreauwater.com/product-assistant

PDF preview unavailable. Download the PDF instead.

V3-204-Spec-Sheet GPL Ghostscript 9.55.0 Adobe InDesign 20.1 (Macintosh)

Related Documents

Preview VIVREAU V3-204 Bottler: Installation Requirements and Technical Specifications
Comprehensive guide to the installation requirements, electrical specifications, ventilation, dimensions, and technical data for the VIVREAU V3-204 Bottler water dispenser.
Preview VIVREAU Extra I-Tap Installation Guide
This guide provides step-by-step instructions for installing and setting up the VIVREAU Extra I-Tap advanced water system, including unpacking, environmental checks, connections, cleaning procedures, and flow rate adjustments.
Preview Vivreau Extra I-Tap Troubleshooting Guide
A troubleshooting guide for the Vivreau Extra I-Tap water dispenser, covering common problems, causes, and remedies for display abnormalities and dispensed water issues.
Preview Vivreau Top Pro User Guide - Water Dispensing Instructions
Comprehensive user guide for the Vivreau Top Pro water dispenser, detailing how to dispense water by volume and use pre-set portion controls for glass or bottle filling.
Preview Vivreau V3-201 and V3-202 Dispensing Systems Service Manual
Comprehensive service manual for Vivreau V3-201 and V3-202 Dispensing Systems, covering installation, operation, maintenance, troubleshooting, and parts replacement.
Preview VIVREAU Extra C-Tap User Guide
User guide for the VIVREAU Extra C-Tap water dispenser, detailing how to select water types and use pre-set portioning for glass and bottle sizes.
Preview VIVREAU PURITY C Water Filter System Manual
Comprehensive manual for the VIVREAU PURITY C water filter system, covering installation, operation, maintenance, troubleshooting, and technical specifications for various models including PURITY C Quell ST, Finest, Steam Advanced, AC, and XtraSafe.