Pytes
Wall-Mounted Outdoor LFP Battery V16
A modern house with solar panels on the roof, showcasing the Pytes Wall-Mounted Outdoor LFP Battery unit mounted on the exterior wall. The battery unit is white with a dark grey front panel and a subtle orange accent light.
Key Features
Enhanced Safety
- ✔️ Tier 1 [Tier 1] automotive-grade 314 Ah cells
- ✔️ Built-in aerosol fire suppression system
- ✔️ ESS emergency shutdown function
- ✔️ Proven and mature BMS protection mechanisms
Reliable
- ✔️ IP66 [IP66 Outdoor Rating] enclosure
- ✔️ C4-M corrosion resistance
- ✔️ Self-heating function for low-temperature operation
Easy & Flexible
- ✔️ Wall-mounted or ground-mounted installation
- ✔️ Seamless integration with mainstream inverters via closed-loop control
- ✔️ Remote monitoring and upgrades
- ✔️ Suitable for indoor or outdoor applications
Scalable
- ✔️ Expandable up to 16 units (256 kWh) in parallel without a Pytes hub
Specifications
Electrical
Battery Chemistry | Lithium Iron Phosphate (LFP) |
---|---|
Rated Voltage | 51.2 V |
Rated Capacity | 314 Ah |
Rated Energy | 16 kWh |
Recommended Continuous Charge / Discharge Current | 125 A (6.4 kW) |
Max Charge / Discharge Current | 200 A (10.24 kW) |
Peak Discharge Current | 300 A (15.36 kW) @ 15 s |
General
Dimensions (W x D x H) | 26.42 x 10.24 x 27.56 inch (671 x 260 x 700 mm) |
---|---|
Weight (lb/kg) | 288/130.5 |
Ingress Protection Rating | IP66 |
Mounting Method ¹ | Wall/Ground |
Terminal | Phoenix Plug & Play DC Connector |
Communication Ports | CAN/RS485 / RS232 / Dry Contact / WiFi |
Cycle Life ² | 8000 cycles |
Warranty ³ | 10 years |
Internal Heating Film
Rated Input Voltage | 51.2 Vdc |
---|---|
Rated Power | 500 W |
Control Temperature | On: ≤41 °F (5°C) Off: ≥59 °F (15 °C) |
Environmental
Charging Temperature ⁴ | 32 °F ~ 131 °F (0 °C ~ 55 °C) |
---|---|
Discharging Temperature | -4 °F ~ 131 °F (-20 °C ~ 55 °C) |
Recommended Operating Altitude | ≤ 9843 ft (3000 m) |
Relative Humidity | 0~95%, non-condensing |
Compliance
- UL 9540 Ed.3 (2023), UL 9540A, UL 1973, UN 38.3
¹ Floor installation requires the additional purchase of a ground mounting bracket.
² Operating conditions: 77 °F ± 7 °F (25 °C ±4 °C), 0.5 C/0.5 C @ 90% DOD, ret @70% (EOL). Total throughput energy: (51.2 V×314 Ah / 1000 × 80% × 8000 / 1000)×90%=92 MWh.
³ 10 years or 8000 cycles (whichever comes first). Optional 2 year warranty extension available for purchase.
⁴ When the ambient temperature is between -0.4°F (-18 °C) and 32 °F (0 °C), the heating film will activate to warm the battery until the temperature reaches the battery charging temperature range. External charging source (PV, grid, generator) is required for heating film operation.