Key Features
- ✔️ Safe: Tier 1 automotive-grade LFP cells, BMS multi-level monitoring and protection, Multi-layer active fire suppression system.
- ☁️ All-Weather: Built-in module-level fans and forced-air cooling system (HVAC) ensure efficient thermal management and reliable operation in high-temperature environments. [IP55] rating for indoor and outdoor installation.
- ? Scalable: Scale seamlessly to MWh-level capacity with our modular battery system – ideal for commercial and industrial-scale applications.
- ? Smart: Remote monitoring with PYTES Battery Cloud.
- ? Flexible: Multiple battery string configurations support a wide range of operating voltage. Universal mounting structure accommodates various inverter models.
Applications
- ? Data Center
- ? Hotel
- ? Agriculture
- ⚡ Utilities
- ? C&I Facilities
- ? VPP
Technical Specifications
Battery Module
Attribute | Value |
---|---|
Battery Chemistry | Lithium Iron Phosphate (LFP) |
Battery Module Energy | 14.34 kWh |
Battery Module Nominal Voltage | 51.2 V |
Battery Module Operating Voltage | 44.8~57.6 V |
Battery Module Nominal Capacity | 280 Ah |
Weight (lb/kg) | 25 ± 11 / 11.6 ± 5 |
System
Attribute | 7S2P Configuration | 15S1P Configuration |
---|---|---|
Max. Battery Pack Internal Configuration ¹ | - | - |
Rated Energy | 200.70 kWh | 215.04 kWh |
Rated Power | 100.35 kW | 107.52 kW |
Operating Voltage | 313.6~403.2 V | 672~864 V |
Rated Charge/Discharge Current | 140 A*2 | 140 A |
Peak Charge/Discharge Current | 170 A*2 (@60 s) | 170 A (@60 s) |
General
Attribute | Value |
---|---|
Dimensions (W x D x H) | 47 x 43 x 89 in (1200 x 1100 x 2250 mm) |
Weight (lb/kg) | 5310.94 / 2409 (7S2P), 5511.56 / 2500 (15S1P) |
Ingress Protection Rating | [IP55] |
Cycle Life ² | 6000 cycles |
Warranty ³ | Battery system: 3 Years ⁴, Battery module: 10 Years |
Environmental
Attribute | Value |
---|---|
Operating Temperature | Charging: 0°C~55°C (32°F~131°F) Discharging: -25°C~55°C (-13°F~131°F) |
Operating Altitude | ≤ 2000 m (≤ 6561.68 ft) |
Relative Humidity | 5%~95%, non-condensing |
Fire Suppression System
Level | Description |
---|---|
Level 1: Detection & Ventilation | Hazardous gas detection activates ventilation system. |
Level 2: Aerosol Suppression | Heat and smoke detection activates aerosol fire suppression system. |
Level 3: Pressure Relief | The explosion relief valve opens automatically if internal pressure exceeds safe limits. |
Level 4: Fire Hose Connection Port | Equipped with a fire hose connection port for firefighter hose attachment. |
HVAC
Attribute | Value |
---|---|
Rated Cooling Capacity | 5000 W (L35) |
Rated Heating Capacity | 2500 W |
Ingress Protection Rating | [IP55] |
Certifications
- UL 9540 Ed.3 (2023)
- UL 9540A
- UL 1973
- UN 38.3
Company Information
Pytes
Power a Better Life
PYTES (USA) ENERGY, INC.
E-mail: pytesusa@pytesgroup.com
Website: www.pytesusa.com
Connect with Pytes: LinkedIn, YouTube, Facebook