GENERAL Life FH250S Underfloor Heating Thermostat
User Manual
General Specifications
The FH250S is a digital room thermostat designed for underfloor heating systems, providing users with more comfortable and affordable heating by allowing precise room temperature settings.
- Sensitive Temperature Measurement
- Temperature Calibration
- Wired connection
- Floor sensor temperature setting
- Hysteresis Adjustment
- ON/OFF Control
FH250S and Equipments
FH250S Room Thermostat
Included accessories: Dowels and Screws.
Technical Data
Specification | Value |
---|---|
Dimensions (H/L/W) | 85.7mm / 85.7mm / 33.5mm |
Operating Current | 230V AC |
Relay NO Switching Current | 7A (240VAC - Resistive load) / 10A (120VAC - Resistive load) |
Temperature Measurement Accuracy | 0.1°C |
Operating Sensitivity | (-2.0°C) - (+2.0°C) |
Operating Temperature Range | (5°C) - (30°C) |
Operating Temperature | (-10°C) - (+50°C) |
Storage Temperature | (-20°C) - (+60°C) |
Room Thermostat Indicators
- Room Temperature
- Underfloor Heating Temperature*
- Set Temperature
- Heating Indicator
If the Heating Indicator is blinking, the heating unit is working. If the Heating Indicator lights up constantly, the heating unit is not working.
*External floor sensor is only active when it is connected.
Room Thermostat Placement
Place your Room Thermostat in a room you use frequently, such as the hall or living room. Avoid installing it in areas with significant air circulation (e.g., near doorways or windows). Do not place it close to heating units (radiators, fireplaces) or in direct sunlight. The recommended placement height is 150 cm from the floor.
[Diagram: Shows recommended placement height of 150 cm from the floor and a minimum distance of 20 cm from air circulation sources like doors or windows.]Room Thermostat Temperature Calibration
Room Thermostat temperature sensors are highly sensitive. Calibrate your thermostat based on the temperature in your living space.
- While the device is off, press and hold the [Button] for 3 seconds.
- Press the [Button] until the calibration menu "[CAL]" appears.
- Adjust the desired temperature difference using the [Button] (right/left). This value can be adjusted between -8°C and +8°C.
- Press the [Button] until the device turns off to save settings and exit.
Note: The recommended temperature calibration setting is 0.0°C.
Room Thermostat Hysteresis Positive Menu
The factory hysteresis positive setting is 0.5°C, adjustable between 0.1°C and 2.0°C. With a 0.5°C setting, the heating unit will stop when the room temperature rises 0.5°C above the set temperature. For example, if set to 22.0°C, heating stops at 22.5°C.
- While the device is off, press and hold the [Button] for 3 seconds.
- Press the [Button] until the "[HSp]" menu appears.
- Adjust the operating sensitivity in the hysteresis positive menu using the [Button] (right/left).
- Press the [Button] until the device turns off to save settings and exit.
Your settings will be saved and applied when the device is turned on.
Room Thermostat Hysteresis Negative Menu
The factory hysteresis negative setting is -0.5°C, adjustable between -0.1°C and -2.0°C. With a -0.5°C setting, the heating unit will activate when the room temperature drops 0.5°C below the set temperature. For example, if set to 22.0°C, heating starts at 21.5°C.
- While the device is off, press and hold the [Button] for 3 seconds.
- Press the [Button] until the "[HSn]" menu appears.
- Adjust the operating sensitivity in the hysteresis negative menu using the [Button] (right/left).
- Press the [Button] until the device turns off to save settings and exit.
Your settings will be saved and applied when the device is turned on.
Floor Sensor Temperature Setting Menu
If a floor sensor is installed, only the GENERAL Life floor sensor should be used to maintain warranty. The factory floor sensor temperature setting is 28°C, adjustable between 23°C and 34°C. The floor sensor operating sensitivity is 1°C. For example, if set to 28°C, heating stops when floor temperature rises to 29°C and restarts when it drops to 27°C.
- Press and hold the [Button] for 3 seconds while the device is off.
- Press the [Button] until the "[nbc]" menu appears.
- Adjust the operating temperature using the [Button] (right/left) in the floor sensor temperature menu.
- Press the [Button] until the device turns off to save settings and exit.
Your settings will be saved and applied when the device is turned on.
Factory Reset
You can reset the Room Thermostat to its factory default settings, including calibration and hysteresis. To factory reset:
- While the device is off, press and hold the [Button] for 3 seconds.
- Press the [Button] until the "[St]" menu appears.
- While in the "[St]" menu, use the [Button] (right/left) to select the "[45]" option and press the [Button].
Your device will turn off and reset to factory settings.
Room Thermostat Working Principle
The thermostat operates based on the average ambient temperature over the last 40 seconds. If the ambient temperature rises above the set hysteresis positive value, the heating unit turns off. If it drops below the hysteresis negative value, the heating unit turns on, maintaining the temperature within a specific range.
If the floor sensor measures a temperature above 28°C, it turns off the heating unit.*
*External floor sensor is only active when it is connected.
[Diagram: Illustrates Room Temperature, Set Temperature, Heating Unit On/Off status over Time. Shows temperature fluctuations around the set point.]Example values: Room Temperature 22.5°C, Set Temperature 22.0°C, Heating Unit On at 21.5°C, Heating Unit Off at 22.5°C.
Wiring Diagrams
WARNING! Operating related to the control panel, heating unit, or electrical installation must be carried out by persons with professional qualifications.
Room Thermostat Wiring Diagram
[Diagram: Shows connections for Room Thermostat with terminals N, L, L1, N1, and NTC. Includes a warning: "Should not be used in case the usage of a wiring center."]Wiring Diagram for Actuators
[Diagram: Shows connections for a 230V AC Actuator with terminals N, L, L1, N1.]Wiring Diagram for Wiring Center
[Diagram: Shows connections for a 230V AC Wiring Center with terminals N, L, L1, N1.]Declaration of Conformity
ISIPARK İÇ VE DIŞ TİC. İNŞ. ISITMA SİSTEMLERİ OTO. SAN. A.Ş., located at Fatih Mah. 1188 Sk. No:13/A Sarnıç Gaziemir İZMİR TÜRKİYE, confirms that the product marked with CE meets the specifications below and is covered by the relevant directives.
Brand: GENERAL Life
Product Name: FH250S
Product Type: Floor Heating Room Thermostat
Compatible Directives:
- Electromagnetic Compatibility Regulation 2014/30/EU (EMC EN 61000-6-3:2007+A1:2011, EN 61000-6-1:2007)
- Low Voltage Directive 2014/35/EU (LVD EN 60730-2-9:2010, EN 60730-1:2011)
Additional Information: The product can be used with boilers with on/off output. ISIPARK is not responsible for the entire system's compliance with directives. This statement is void if modifications are made to the product without approval.
[CE Mark]
ISIPARK Contact: Fatih Mah. 1188 Sokak No:13/A Sarnıç, Gaziemir, İZMİR, TÜRKİYE. Tel: (0232) 457 99 05, Fax: (0232) 457 91 22. Mersis No: 0466062137000016. Gaziemir V.D.: 466 073 1206.
Warranty Conditions
- Warranty period: 2 years from the invoice date, covering manufacturing defects.
- Devices are delivered in working condition. On-site commissioning incurs a service fee.
- Warranty repairs are performed at the factory. Transportation costs for service personnel and equipment are the customer's responsibility.
- Maintenance is performed at the company. Travel fares for maintenance belong to the customer.
- Malfunctions are tested to determine cause (customer vs. manufacturer fault).
- Manufacturer-induced errors within the warranty period allow for replacement or repair at the manufacturer's expense, unless exceeding product price.
- Customer-induced faults are entirely at the customer's expense.
- Customers must report damages from the start of the warranty period; failure to do so may forfeit rights under article 6.
- Malfunctions due to use contrary to the User Manual are not covered.
- Damage from impact, breakage, or scratches voids the warranty.
- Damage from using other brands/models without approval is not covered.
- Battery leakage, rust, oxidation, or liquid contact in humid/acidic environments are not covered.
- Remove batteries if the product is unused for over 15 days; subsequent malfunctions are not covered.
- Transportation damage is not covered; customers may opt for transportation insurance.
- Damage from mains voltage or faulty electrical installation is not covered.
- Force majeure events (fire, flood, earthquake) are not covered.
- All devices and parts are under the company's warranty.
- Repair time is added to the warranty period. Repairs should not exceed 20 working days. This period starts from notification. If not repaired within 20 days, a replacement product of similar features must be provided until repair is complete.
- Refund or price discount may be requested if:
- The product fails 4 times in a year or 6 times within the warranty period, affecting its main purpose.
- Maximum repair time is exceeded.
- Repair is impossible due to lack of service station or other reasons, as determined by a report.
- Complaints can be made to consumer courts or arbitration committees.
- The warranty document must be kept. Loss of the document will result in a fee for repair/replacement.
Warranty Certificate
Manufacturer: ISIPARK İÇ VE DIŞ TİC. A.Ş.
Address: Fatih Mah. 1188 Sk. No:13/A Sarnıç Gaziemir İzmir-TÜRKİYE
Tel: +90 (232) 457 99 50
Fax: +90 (232) 457 91 22
E-mail: generallife@generallife.com.tr
Authorized Signature: [Signature Placeholder]
Company Stamp: [Stamp Placeholder]
Product Type: Floor Heating Room Thermostat
Brand: GENERAL Life
Model: FH250S
Warranty Period: 2 Years
Max. Time to Repair: 20 Days
Bandrol and Serial Number: [Placeholder]
Vendor:
Title: [Vendor Title Placeholder]
Address: [Vendor Address Placeholder]
Tel: [Vendor Tel Placeholder]
Fax: [Vendor Fax Placeholder]
E-Mail: [Vendor Email Placeholder]
Invoice Date and Number: [Placeholder]
Delivery Time and Place: [Placeholder]
Authorized Signature: [Signature Placeholder]
Company Stamp: [Stamp Placeholder]
Product Type: Floor Heating Room Thermostat
Brand: GENERAL Life
Model: FH250S
[Stamp Placeholder] V-01.2021
ISIPARK reserves the right to change product specifications and user manuals. For all changes, please visit generallife.com.tr.