Jandy Versa Plumb Kits Installation Instructions

Important Safety Information

WARNING: For safety, only the plumbing pieces in the Versa Plumb kits are intended for DIY homeowner installation. Any pool equipment such as heaters, filters, and pumps must be installed and serviced by a licensed and qualified contractor. Failure to follow instructions may result in property damage, serious injury, or death. Improper installation voids the warranty.

WARNING: To prevent electrical shock, carbon monoxide poisoning, explosion, or fire, turn off all electrical power, gas supply, and other power sources to the pool equipment before installation. Follow pool filter instructions to properly drain the filter.

WARNING: Never start the pump while standing within five (5) feet of the filter. Pressurized air in the system can cause the filter lid to blow off, leading to severe injury or death. Consult equipment manuals for proper startup procedures.

WARNING: When using CPVC cement, use a cement listed by NSF® or an equivalent Nationally Recognized Testing Laboratory (NRTL). Read and follow the cement manufacturer's instructions.

IMPORTANT: Pool/spa water inlet temperature must not exceed 122°F (50°C). Spa water should not exceed 104°F (40°C). Water temperatures between 100°F (38°C) and 104°F (40°C) are considered safe for healthy adults. Lower temperatures are recommended for children or extended spa use.

Solar System Safety: Solar collector panels must drain completely when the pump is off and require an automatic air relief/vacuum-breaker valve. Use only solar collector panels with these valves to prevent damage and scald hazards. Release all air before testing. Test pressure must not exceed 35 psi. Test temperature must not exceed 100°F (38°C).

Introduction

This document provides instructions for installing and plumbing the Jandy Pro Series Versa Plumb kits for pool and spa equipment pads. Read all instructions completely before starting. Use the parts list to identify all components. If parts are missing, contact your local Jandy distributor.

These instructions are for the following Versa Plumb Kits:

  • VPK-CVSTD -- CV Standard, Versa Plumb Kit
  • VPK-CVSLR -- CV Solar, Versa Plumb Kit
  • VPK-CSSTD -- CS Standard, Versa Plumb Kit

Technical Assistance and Ordering

For technical assistance, contact the Technical Support Department at 1.800.822.7933.

To order parts, contact your nearest Jandy dealer or distributor. If unavailable, contact Zodiac Pool Systems, Inc. at 1.800.822.7933. In Canada, contact Zodiac Pool Systems Canada, Inc. Customer Support at 1.888.647.4004.

Reference manuals such as the Jandy Valve Actuator Installation and Operational Manual, AquaLink RS All Button and OneTouch™ Control Systems Installation Manual, and Jandy Valve Plumbing Manual are available on jandy.com or by calling 1.800.822.7933.

Installation Instructions

A. CV Standard Kit (VPK-CVSTD)

  1. Position pool suction and return lines in front of the equipment pad.
  2. Position equipment pad components, bringing piping through perforated holes on the template.
  3. Connect the pump to suction lines (pool or pool/spa combo) using CPVC cement and primer. Pipe length into the suction port should be a minimum of four times the pipe diameter.
  4. Connect the pump to the filter using the sweep elbow with the 1½" NPT plug component (marked "A" in Figure 1) using CPVC cement and primer.
  5. Connect the filter to the heater using the straight pipe with union nuts (marked "B" in Figure 1) using CPVC cement and primer.
  6. Attach the check valve (marked "C" in Figure 1) to the outlet of the LXi™, ensuring the flow arrow points correctly.
  7. Optionally, attach a salt chlorinator spool or blank spool assembly to the check valve and run the return line from the spool to the trench using CPVC cement and primer.

Note: The kit includes two (2) additional 3-way valves and a spare 12" of pipe for adding components to the return system.

B. CV Solar Kit (VPK-CVSLR)

B.1 Piping and Valve Connections to the Solar Stub-Outs

  1. Position pool suction and return lines in front of the equipment pad.
  2. Position equipment pad components, bringing piping through perforated holes on the template.
  3. Connect the pump to suction lines (pool or pool/spa combo) using CPVC cement and primer. Pipe length into the suction port should be a minimum of four times the pipe diameter.
  4. Connect the pump to the filter using the sweep elbow with the 1½" NPT plug component (marked "A" in Figure 2) using CPVC cement and primer.
  5. Connect the filter to the heater using the provisional solar assembly component with union nuts (marked "B" in Figure 2) using CPVC cement and primer.
  6. Attach the check valve (marked "C" in Figure 2) to the outlet of the heat pump, ensuring the flow arrow points correctly.
  7. Optionally, attach a salt chlorinator spool or blank spool assembly to the check valve and run the return line from the spool to the trench using CPVC cement and primer.
  8. Install a check valve and piping (see Figure 3).
  9. Install the Jandy valve actuator onto the Jandy 3-port diverter valve (see Figure 3).
  10. Install the solar controller per manufacturer's instructions and connect to the Jandy valve actuator. Adjust the actuator for correct diverter positions (Figures 4 & 5).

Note: The check valve and Jandy valve actuator are not included in the CV Solar Versa Plumb Kit.

Note: The kit includes two (2) additional 3-way valves and a spare 12" of pipe for adding components to the return system.

C. CS Standard Kit (VPK-CSSTD)

  1. Position pool suction and return lines in front of the equipment pad.
  2. Position equipment pad components, bringing piping through perforated holes on the template.
  3. Connect the pump to suction lines (pool or pool/spa combo) using CPVC cement and primer. Pipe length into the suction port should be a minimum of four times the pipe diameter.
  4. Connect the pump to the filter using the sweep elbow with the 1½" NPT plug component (marked "A" in Figure 6) using CPVC cement and primer.
  5. Connect the filter to the heat pump using the flange tail piece with union nut (marked "B" in Figure 6). Glue the flange tail piece directly into the heat pump inlet port using CPVC cement and primer.
  6. Attach the check valve (marked "C" in Figure 6) to the outlet of the heat pump, ensuring the flow arrow points correctly.
  7. Optionally, attach a salt chlorinator spool or blank spool assembly to the check valve and run the return line from the spool to the trench using CPVC cement and primer.

Note: The kit includes two (2) additional 3-way valves and a spare 12" of pipe for adding components to the return system.

Parts List

A. CV Standard Kit (VPK-CVSTD)

Description Qty
Filter to Heater Connector1
Heater to Chlorinator Connector1
Pump to Filter Connector1
12" Pipe1
Blank Spool Assembly1
3-Way Valve2
Installation Instructions1

Visual representation of CV Standard Kit components: Pump to Filter Connector, Filter to Heater Connector, Heater to Chlorinator Connector, 12 in. Pipe, Blank Spool, 3-Way Valve (Qty. 2).

B. CV Solar Kit (VPK-CVSLR)

Description Qty
Filter to Heater Connector1
Heater to Chlorinator Connector1
Pump to Filter Connector1
12" Pipe1
Blank Spool Assembly1
3-Way Valve2
Installation Instructions1

Visual representation of CV Solar Kit components: Pump to Filter Connector, Filter to Heater Connector with Solar Stubbs, Heater to Chlorinator Connector, 12 in. Pipe, Blank Spool, 3-Way Valve (Qty. 2).

C. CS Standard Kit (VPK-CSSTD)

Description Qty
Filter to Heater Connector1
Heater to Chlorinator Connector1
Pump to Filter Connector1
12" Pipe1
Salt Chlorinator Spool Assembly1
3-Way Valve2
Installation Instructions1

Visual representation of CS Standard Kit components: Pump to Filter Connector, Filter to Heater Connector, Heater to Chlorinator Connector, 12 in. Pipe, Salt Chlorinator Spool, 3-Way Valve (Qty. 2).

Reference Diagrams

CV Standard Installation Diagram

Schematic showing the plumbing layout for a CV Standard installation, detailing suction lines, pump, filter, heater, and return lines, including a blank spool, filter to heater connector, and heater to chlorinator connector.

CV Solar Installation Diagram

Schematic illustrating the plumbing layout for a CV Solar installation, showing connections to solar stubbs, suction lines, pump, filter, heater, and return lines, including a blank spool, filter to heater connector, and heater to chlorinator connector.

CS Standard Installation Diagram

Schematic depicting the plumbing layout for a CS Standard installation, including connections to a chlorinator spool, suction lines, pump, filter, heater, and return lines, with filter to heater connector and heater to chlorinator connector.

Connections from Versa Plumb piping to the Solar Connector

Diagram showing how Versa Plumb piping connects to a solar system, detailing connections from solar collectors, a check valve, filter, heater, and a 3-port diverter valve. Includes diagrams for Diverter Valve Position (Solar Disabled) and Diverter Valve Position (Solar Enabled).

Versa Plumb Installation Diagram (CV Standard and CV Solar Kit)

Detailed dimensional drawing showing the placement and connection points for CV Standard and CV Solar kits on an equipment pad, including various measurements for components like the filter, pump, and heater.

Versa Plumb Installation Diagram (CS Standard)

Detailed dimensional drawing illustrating the placement and connection points for the CS Standard kit on an equipment pad, including various measurements for components like the filter, pump, and heater.

Plumbing for Pool and Spa Combination

This section describes simplified plumbing setups for pool and spa systems sharing a filter pump, filter, and heater. It explains how Jandy Valve Actuators (JVAs) synchronize circulation between pool and spa. Consult specific Jandy manuals for detailed information.

Note: In a shared system, the spa water must be able to overflow back to the pool.

WARNING: Flow rates must not exceed manufacturer maximums for suction fittings or skimmers. Exceeding recommended flow rates can cause serious personal injury or death.

Diagram illustrating a shared pool and spa plumbing setup, showing water flow from main drains/skimmers to the pump/equipment and back to the pool/spa, with provisions for valve actuators.

Models: Jandy, Versa Plumb, Kits, VPK-CVSTD, CV Standard, Versa Plumb Kit, VPK-CVSLR, CV Solar, VPK-CSSTD, CS Standard

File Info : application/pdf, 12 Pages, 5.62MB

PDF preview unavailable. Download the PDF instead.

H0330900

References

Adobe PDF Library 15.0 Adobe InDesign 16.0 (Windows)

Related Documents

Preview Jandy Pro Series Pool and Spa Air Blower Installation Guide
Detailed installation guide for Jandy Pro Series Pool and Spa Air Blowers (Models PSB110, PSB115, PSB120, PSB210, PSB215, PSB220). Covers essential safety precautions, blower sizing calculations, plumbing configurations (Standard, Long Run, Below Grade, Hartford Loop), and electrical wiring instructions for safe and effective operation.
Preview Jandy CL and CV Series Cartridge Pool Filters: Installation, Operation, and Maintenance Manual
Comprehensive guide for installing, operating, and maintaining Jandy CL and CV Series Cartridge Pool Filters. Includes safety warnings, specifications, troubleshooting, parts lists, and warranty information.
Preview Jandy TC3 Flush Mount Pool/Spa Return Jet Installation Instructions
Step-by-step installation guide for the Jandy TC3 Flush Mount Pool/Spa Return Jet, including important safety precautions and installation tips for pool and spa professionals.
Preview Jandy TruFit Bubbler Owner's Manual: Installation and Operation Guide
Comprehensive guide for the Jandy TruFit Bubbler with Pressure Check Technology, covering installation, operation, winterizing, and troubleshooting for swimming pools. Includes model JHCBUB.
Preview Jandy TruClear Cell Replacement: Spare Parts Installation Guide
Official installation instructions for the Jandy TruClear Cell Replacement (Part R0693900) for Jandy Pro Series pool systems. Includes safety warnings, package contents, and step-by-step installation procedures.
Preview Jandy Variable-Speed Pumps Installation and Operation Manual - VSFHP185DV2A, VSFHP270DV2A, VSPHP270DV2A
Comprehensive installation, operation, and maintenance guide for Jandy Variable-Speed Pumps (VSFHP185DV2A, VSFHP270DV2A, VSPHP270DV2A). Learn about features, safety precautions, electrical installation, troubleshooting, and performance for energy-efficient pool pump operation.
Preview Jandy Pro Series Valve Actuator Model JVA 2444 Installation and Operation Manual
This manual provides detailed instructions for the installation, operation, synchronization, maintenance, and troubleshooting of the Jandy Pro Series Valve Actuator Model JVA 2444. It includes safety warnings, wiring diagrams, and specifications.
Preview Jandy Pro Series Spring Check Valve Installation Instructions
Installation guide for the Jandy Pro Series Spring Check Valve, detailing safety precautions, plumbing connections for various pipe sizes, correct orientation, maintenance, and optimal location for pool systems. Includes part numbers and diagrams.