Jandy Pro Series Pool and Spa Air Blower Installation Instructions

Models: PSB110, PSB115, PSB120, PSB210, PSB215, PSB220

Important Safety Instructions

WARNING: FOR YOUR SAFETY

This product must be installed and serviced by a contractor who is licensed and qualified in pool equipment by the jurisdiction in which the product will be installed. Where state or local requirements exist, the maintainer must be a professional with sufficient experience in pool equipment installation and maintenance so that all instructions in this manual can be followed exactly. Before installing this product, read and follow all warning notices and instructions that accompany this product. Failure to follow warning notices and instructions may result in property damage, personal injury, or death. Improper installation and/or operation will void the warranty. Improper installation and/or operation can create unwanted electrical hazards which can cause serious injury, property damage, or death.

Turn off all circuit breakers required to prevent the possibility of electric shock. If you have any questions or need further details, please contact Zodiac Pool Systems Customer Support at: 1.800.822.7933.

WARNING: RISK OF ELECTRIC SHOCK

Install at least 5 feet (1.5 m) from tub water using nonmetallic plumbing. Install blower no less than 1 foot (305 mm) above the maximum water level or with an approved Hartford loop configuration as outlined in section 2 "Plumbing" to prevent water from contacting electrical equipment. Install in accordance with the installation instructions.

Pressure Testing:

NOTICE: These parameters apply to Zodiac equipment only. For non-Zodiac equipment, consult the equipment manufacturer.

To Reduce the Risk of Injury:

To reduce the risk of injury, do not permit children to use this product.

Jandy Blowers are powered by high-voltage electric motors and must be installed by a licensed or certified electrician or a qualified swimming pool service technician.

WARNING: Incorrectly installed equipment may fail, causing severe injury or property damage.

WARNING: Do not install on a plumbing line that can be closed or shut off. The blower may create severe enough pressures to cause property damage or injury.

Attention installer: This manual contains important information about the installation, operation, and safe use of this product. This information should be given to the owner/operator of this equipment.

SAVE THESE INSTRUCTIONS

1. Select Blower

Correctly sizing the blower for your application is a critical step to the sustained operational quality of your Jandy Pro Series Pool and Spa Blower. Damage or failure due to an improperly sized blower is not covered under warranty.

Sizing Worksheets

Calculate Back Pressure

Calculate back pressure as a measure of "inches of water". Verification of this figure can be made by using a manometer.

Formula Components:

Diagram Description: A diagram illustrates how to measure 'a' and 'a¹', and shows pipe ('b'), elbows ('c', 'd'), and check valves ('e') in a typical plumbing setup.

Total Back Pressure (Inches of Water) = [Calculation based on inputs]

Calculate Airflow

Choose an air hole size from the chart at left and apply the conversion factor in the formula below to determine total airflow in standard cubic feet per minute (SCFM).

AIR HOLE SIZE CONVERSION FACTOR
1"2.4
1 1/8"1.5
1 1/4"1.1
1 3/8"0.6
1 1/2"0.27
1 5/8"0.15
1 3/4"0.1

Total Airflow (SCFM) = [No. of Holes] x [Conversion Factor]

WARNING: Installing an insufficiently sized blower will increase back pressure. Failure to accurately follow the blower sizing calculations provided could result in excessive back pressure. Excessive pressure can cause damage that could result in electrocution causing severe injury or death.

Determine Blower Needed

Locate the total back pressure, calculated above, and draw a horizontal line. Locate the total airflow from the previous step and draw a vertical line. These lines will intersect on the performance curve of the minimum HP blower required for your application.

Diagram Description: Performance Curves (60 HZ) are shown, plotting Air Flow Rate (SCFM) against Pressure H2O (Inches of Water). Lines indicate maximum back pressures (40", 50", 65") and required HP based on the intersection of calculated back pressure and airflow. Models are associated with specific maximum back pressures.

Voltage 1.0 HP 1.5 HP 2.0 HP
120VPSB110PSB115PSB120
240VPSB210PSB215PSB220

4. Install Blower

Installation must be done in accordance with the National Electrical Code® ("NEC®" or NFPA-70®) in the US, the Canadian Electrical Code ("CEC" or CSA C22.1) in Canada, and/or any other local and national installation codes.

  1. Refer to the "Select Blower" section (facing page) to ensure that you have the correct blower size for your application.
  2. Pressure tests to the system should be done prior to the installation of the blower. See Warning Section on adjacent page.
  3. Use 2" PVC pipe from the blower to jets or bubblers.
  4. Slide Blower onto PVC Pipe. Lower until the stop tabs make contact with the PVC pipe.
  5. Blower should be installed vertically, away from direct sunlight.
  6. Do not glue or otherwise permanently attach the blower to plumbing.
  7. Do not remove the blower check valve diaphragm.
  8. Drill two (2) 1/8" pilot holes through the textured fastener safe area marked on the blower body. The holes should be drilled through the blower body and PVC pipe. The holes should be oriented 180° from one another.
  9. Install one (1) 1/2" 8-18 thread forming screw into each of the previously drilled pilot holes. The screws and pipe should not interfere with the normal travel of the check valve diaphragm.
  10. The blower also comes equipped with a mounting bracket which can be used to secure the blower to a vertical surface such as a wall or post.
  11. If not used, the bracket can be removed and stored.

CAUTION: Blower must be affixed to the plumbing using the fasteners recommended in these instructions. Failure to do so may allow the blower to come free of the plumbing during operation which could damage equipment and prevent proper blower operation.

WARNING: Blower must be installed in an area well away from sources of exhaust such as gas pool and spa heater. Please ensure that this blower is installed according to local codes and Authority Having Jurisdiction (AHJ) requirements.

WARNING: Do not use chemical adhesives to affix the blower to the air inlet line. Fumes from chemical adhesives may accumulate in the piping and explode causing property damage, serious injury or death.

Diagram Description: Diagrams illustrate the blower attachment to 2" PVC pipe using screws through designated "Fastener Safe Area" on the blower body. An illustration shows the "Diaphragm Travel Distance" and "Stop Tabs". A mounting bracket is also depicted.

2. Plumbing

Diagrams illustrate various plumbing configurations:

Hartford Loop: Use this configuration if the blower air line drops below the spa water level to prevent the line from filling with water. It involves routing the air line upwards and then downwards before connecting to the jets, ensuring the highest point of the loop is above the water level.

Check Valve: Install a 1/2 lb. U.L. listed check valve between the blower and the jets to prevent water damage to the blower. Ensure that check valves are accessible for servicing.

Note: Do not install adjustable jets, as they may cause excessive back pressure.

Diagram Description: Detailed diagrams show the plumbing for Standard, Long Run, and Below Grade installations, including placement of the blower, 2" PVC pipe, check valve, jets, and water lines. The Hartford Loop configuration is also illustrated.

3. Wiring

Installation of this equipment should be performed by a licensed electrician and conform to all National Electrical Code® (NEC®), state, and local codes.

  1. Ensure all power to the blower has been disconnected at the main breaker.
  2. Remove blower front door by removing the two (2) screws sliding the door downward and pulling the door free.
  3. Pull in voltage source and ground wire from Power Center.
  4. Connect wires from power center to the corresponding wires from the blower motor. Use the wiring diagrams below for reference. The 120 or 240 toggle switch will come preinstalled with flag terminals. Connections will need to be made with Wire nuts.

RISK OF ELECTRIC SHOCK WHICH CAN RESULT IN SERIOUS INJURY OR DEATH: Before attempting installation, ensure that all power to the device is disconnected/turned off at the circuit breaker. Be careful not to damage or abrade any wiring or other components.

Diagram Description: Wiring diagrams for 120V and 240V systems are provided. They show connections from the Power Center (Line 1, Neutral, Ground for 120V; Line 1, Line 2, Ground for 240V) to a toggle switch and then to the blower motor. Legends identify wire types.

Models: PSB110 Pro Series Spa Air Blower, PSB110, Pro Series Spa Air Blower, Spa Air Blower, Air Blower, Blower

File Info : application/pdf, 2 Pages, 2.10MB

PDF preview unavailable. Download the PDF instead.

H0507900 REVJ Adobe InDesign CC 13.0 (Windows) iLovePDF

Related Documents

Preview Jandy Pro Series Pool and Spa Air Blower Installation Guide
Comprehensive installation instructions for Jandy Pro Series Pool and Spa Air Blowers (PSB110, PSB115, PSB120, PSB210, PSB215, PSB220), covering safety, sizing, plumbing, and wiring.
Preview Jandy Pro Series Pool and Spa Air Blower Installation Instructions
Comprehensive installation guide for Jandy Pro Series Pool and Spa Air Blowers, covering selection, plumbing, wiring, and safety precautions for models PSB110, PSB115, PSB120, PSB210, PSB215, and PSB220.
Preview Jandy Pro Series Valve Actuator Model JVA 2444 Installation and Operation Manual
This manual provides detailed instructions for the installation, operation, synchronization, maintenance, and troubleshooting of the Jandy Pro Series Valve Actuator Model JVA 2444. It includes safety warnings, wiring diagrams, and specifications.
Preview Jandy TC3 Flush Mount Pool/Spa Return Jet Installation Instructions
Step-by-step installation guide for the Jandy TC3 Flush Mount Pool/Spa Return Jet, including important safety precautions and installation tips for pool and spa professionals.
Preview Jandy TruClear Cell Replacement: Spare Parts Installation Guide
Official installation instructions for the Jandy TruClear Cell Replacement (Part R0693900) for Jandy Pro Series pool systems. Includes safety warnings, package contents, and step-by-step installation procedures.
Preview Jandy Versa Plumb Kits Installation Instructions
Comprehensive installation instructions for Jandy Pro Series Versa Plumb Kits, including CV Standard, CV Solar, and CS Standard models. Covers safety precautions, parts lists, and plumbing diagrams for pool and spa installations.
Preview Jandy PlusHP Pump: High Performance Pool Pump
Discover the Jandy Pro Series PlusHP Pump, engineered for maximum power and ultimate performance in a compact design. Features quiet technology, high efficiency, and detailed specifications for pool and spa applications.
Preview Jandy Variable-Speed Pumps Installation and Operation Manual - VSFHP185DV2A, VSFHP270DV2A, VSPHP270DV2A
Comprehensive installation, operation, and maintenance guide for Jandy Variable-Speed Pumps (VSFHP185DV2A, VSFHP270DV2A, VSPHP270DV2A). Learn about features, safety precautions, electrical installation, troubleshooting, and performance for energy-efficient pool pump operation.