LANCOM ISG-1000 Quick Reference Guide

Cloud-ready

Mounting and Connecting the Device

This section describes the physical connections and controls of the LANCOM ISG-1000.

Device Ports and Controls

  • a USB interface: For connecting USB printers or USB storage devices.
  • b Serial configuration interface: Use the included serial cable to connect to a configuration/monitoring device.
  • c SFP / TP Ethernet interfaces (combo ports): For inserting SFP modules and connecting compatible cables. SFP modules and cables are not included.
  • d TP Ethernet interfaces (ETH 1 - ETH 4): Connect to a PC or LAN switch using enclosed kiwi-colored cables.
  • e TP Ethernet interface (ETH 5): Connect to a PC or LAN switch using an enclosed kiwi-colored cable.
  • f Reset button: Press for up to 5 seconds for a device restart. Press until first LED flash for configuration reset and restart.
  • g Power connector and grounding point (device back side): Supply power via the power connector using the supplied IEC power cable.
  • h Grounding: [Attention] High touch current possible! Connect to earth before connecting the power supply. Remove the blind screw and use the enclosed grounding screw.

Setup Recommendations

Please observe the following when setting up the device:

  • The mains plug must be freely accessible.
  • For desktop operation, attach the adhesive rubber footpads.
  • Do not rest objects on the device or stack multiple devices.
  • Keep ventilation slots clear.
  • Mount the device into a 19" unit in a server cabinet using provided screws and brackets.

[Important] Before initial startup, consult the installation guide for intended use. Operate the device only with a professionally installed power supply at a nearby, accessible power socket.

LED Status Indicators

The following table details the status of the device's LEDs:

POWER LED Status

StatusDescription
OffDevice switched off
Green, permanently*Device operational, or device paired/claimed and LANCOM Management Cloud (LMC) accessible
Green / red, blinkingNo password set. Configuration data is unprotected.
Red, blinkingCharge or time limit reached
1x green inverse blinking*Connection to LMC active, pairing OK, device not claimed
2x green inverse blinking*Pairing error, or LMC activation code not available
3x green inverse blinking*LMC not accessible, or communication error

[Note] *Additional power LED statuses are displayed in 5-second rotation if the device is managed by LANCOM Management Cloud.

TEMP LED Status

StatusDescription
Green, permanentlyCPU temperature OK
Red, blinkingHardware failure of the fan or CPU temperature too high; additional acoustic signal.

LCD Display

The LCD display rotates through the following information:

  • Device name
  • Firmware version
  • Device temperature
  • Date and time
  • CPU load
  • Memory usage
  • Number of VPN tunnels
  • Data transfer in reception direction
  • Data transfer in transmission direction

ETH 1 - ETH 4 TP LED Status

LEDsDescription
Both LEDs offNo networking device attached
Green, permanentlyConnection to network device operational, no data traffic
Green, flickeringData transmission
Orange off1000 Mbps
Orange, permanently10 / 100 Mbps

ETH 1 - ETH 4 SFP LED Status

LEDsDescription
Both LEDs offNo networking device attached
Green, permanentlyConnection to network device operational, no data traffic
Green, flickeringData transmission
Orange off1000 Mbps
Orange, permanently10 / 100 Mbps

ETH 5 LED Status

LEDsDescription
Both LEDs offNo networking device attached
Green, permanentlyConnection to network device operational, no data traffic
Green, flickeringData transmission
Orange off1000 Mbps
Orange, permanently10 / 100 Mbps

Technical Data

Hardware

ParameterSpecification
Power supplyInternal power supply unit (110–230 V, 50–60 Hz)
Power consumption40 W
EnvironmentTemperature range 5–40 °C; humidity 0–95 %; non-condensing
HousingRobust metal housing, 19" 1U with removable mounting brackets, network connectors on the front
Number of fans3

Interfaces

InterfaceDescription
ETH4 individual 10 / 100 / 1000-Mbps Gigabit Ethernet ports (ETH 1 - ETH 4); 1x Gigabit Ethernet port (ETH 5). Up to 4 ports can be switched as additional WAN ports with load balancing. Ethernet ports can be electrically disabled within LCOS configuration.
USBUSB 2.0 Hi-Speed host port for connecting USB printers (USB print server) or USB data media (FAT file system); bi-directional data exchange is possible (max. 480 Mbps)
Serial InterfaceSerial configuration interface

WAN Protocols

ProtocolDetails
EthernetPPPoE, Multi-PPPoE, ML-PPP, PPTP (PAC or PNS) and plain Ethernet (with or without DHCP), VLAN, IP

Declaration of Conformity

LANCOM Systems GmbH | Adenauerstrasse 20/B2 | D-52146 Wuerselen, declares that this device is in compliance with Directives 2014/30/EU, 2014/35/EU, 2011/65/EU, and Regulation (EC) No. 1907/2006. The full text of the EU Declaration of Conformity is available at the following Internet address: www.lancom-systems.com/doc

Package Content

Documentation

  • Quick Reference Guide (DE, EN)
  • Installation Guide (DE/EN)

Accessories

  • 2 Ethernet cables, 3 m (kiwi colored connectors)
  • 1 serial configuration cable 1.5 m
  • 1 IEC power cord 230 V (not for WW devices)
  • 1 grounding screw

Software Licenses

This product contains separate open-source software components subject to their own licenses, particularly the General Public License (GPL). License information for the device firmware (LCOS) is available via the device's WEBconfig interface under “Extras > License information”. Source files for corresponding software components will be made available on a download server upon request, if required by the license.

Models: ISG-1000 GmbH System, ISG-1000, GmbH System

File Info : application/pdf, 1 Pages, 337.12KB

PDF preview unavailable. Download the PDF instead.

HWS ISG-1000 EN

References

Adobe PDF Library 15.0 Adobe InDesign 16.3 (Windows)

Related Documents

Preview LANCOM 883 VoIP Quick Reference Guide
A concise guide to the LANCOM 883 VoIP device, covering connection instructions, technical specifications, interface details, LED status indicators, package contents, and setup recommendations.
Preview LANCOM LX-6400 Hardware Quick Reference Guide
A quick reference guide for the LANCOM LX-6400, detailing hardware features, LED descriptions, mounting, and technical specifications.
Preview LANCOM 1800EFW-5G Quick Installation Guide
This guide provides essential information for the quick installation and setup of the LANCOM 1800EFW-5G device, including safety instructions, regulatory compliance, and configuration options.
Preview LANCOM LX-7300 Quick Installation Guide
This guide provides essential information for the initial setup and configuration of the LANCOM LX-7300 network device, including safety instructions, connection options, and regulatory compliance.
Preview LANCOM LX-7200 Quick Installation Guide: Setup and Configuration
Comprehensive quick installation guide for the LANCOM LX-7200 access point. Learn about safety instructions, hardware overview, initial setup, configuration options (LMC, WEBconfig, LANconfig), and regulatory compliance.
Preview LANCOM Switches Installation Guide
A comprehensive guide for installing and configuring LANCOM Switches, covering network management, safety precautions, connection methods, and support resources.
Preview LANCOM R883+ Router: Quick Reference Guide for Setup and Technical Details
This guide provides quick reference information for the LANCOM R883+ router, covering device setup, connection instructions for various interfaces (VDSL, Ethernet, ISDN, Analog, USB), technical specifications, and LED status indicators.
Preview LANCOM Switches Installation Guide: Setup, Configuration, and Management
This guide provides comprehensive instructions for installing, configuring, and managing LANCOM Switches. It covers essential safety information, environmental requirements, power supply, network management options (Unmanaged vs. Managed), integration with the LANCOM Management Cloud (LMC), command-line interface access, and details on LANCOM's service and support offerings.