DELLA Portable Air Conditioner Use and Care Manual

Part Number: 048-GM-48266

Contents

Safety Instructions

1. Electrical Specifications

  1. All wiring must comply with local and national electrical codes and be installed by a qualified electrician. If you have any questions regarding to the following instructions, please contact a qualified electrician.
  2. The unit must be installed in accordance with national wiring regulations. Check available power supply and resolve any wiring problems before installation and operation of this unit.
  3. For your safety and protection, this unit will be grounded through the power cord plug when plugging into a matching wall outlet. If you are not sure whether the wall outlet at your home are properly grounded, please consult an electrician. If supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified person in order to avoid any hazards.
  4. This appliance is not intended for people (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Young children should be supervised to ensure that they do not play with the appliance.

2. WARNING:

To reduce the risk of fire, electrical shock or injury when using your air conditioner, follow up these basic precautions:

3. Cautions:

Remark: Do not use this unit in cooling mode if the ambient temperature is higher than 35°C.

Function and Technical Specification

Remark: The above cooling capacity is measured at standard working condition of ambient temperature dry-bulb 35°C, wet-bulb 24°C (Indoor and outdoor, the same conditions).

Features and Identification of Parts

1. Features

2. Identification of Parts:

A diagram shows the different parts of the air conditioner. Key parts include:

Operation and Settings

1. Control Panel

This section explains proper mobile air conditioner operation. The control panel features buttons for Timer, Fan, Mode, Power, and fan speed (High/Low), along with indicators for Timer, Fan speed, Water-full, Cool, Fan, Dehumidify, Sleep, Power, and a LED display window for temperature and timer settings.

Figure 3 illustrates the control panel layout and button functions.

2. Control Panel Operation

This unit operates in Cool, Dehumidifying, Fan, and Sleep modes.

  1. Turn on the unit: Plug in the unit. The POWER indicator will be red. Press the POWER button to turn on the unit. The POWER indicator will turn green, and the unit will operate in Cool Mode with the temperature set to 24°C and fan at high speed.
  2. Select operating mode: Press the MODE button to cycle through COOL, DEHUMIDIFY, and FAN modes. The corresponding indicator will light up. To enter Sleep Mode under cooling mode, press the "Timer" and "▼" buttons together.
  3. Adjust temperature: Under cooling mode, the temperature can be set between 17-30°C. Use the "▲" or "▼" buttons to increase or decrease the temperature by 1°C. Pressing "▲" and "▼" buttons together toggles between Celsius and Fahrenheit.
  4. Adjust fan speed: Press the FAN button to select the desired fan speed: Low or High.
  5. Stand-by: Press the POWER button again to stop the unit. The POWER indicator will turn red.

Notice: Working principle for each mode and function

1. Cool mode:

2. Fan mode:

3. Dehumidify mode:

4. Sleep mode:

5. Timer Operation:

3. Remote Control Operation

The remote control transmits signals to the system. The remote control has buttons for Power, Timer, High/Low fan speed, Up/Down temperature/timer settings, C/F conversion, Cool mode, Fan mode, Dry mode, and Sleep mode.

Before using your remote, install the AAA batteries into the remote control:

  1. Press and glide the battery cover on the back of the remote control to remove it.
  2. Insert two new alkaline AAA batteries, ensuring correct polarity.
  3. Reattach the battery cover, ensuring the locking tab clicks into place.

Notes:

Remote Control Storage Area

If the air conditioner will not be used for an extended period, remove the batteries from the remote control. The air conditioner has a special storage place for the remote control. Always store the remote control in this compartment after use.

CAUTION: If battery liquid gets on skin or clothes, wash with clean water. Do not use the remote if batteries leak. If battery liquid is ingested, brush teeth and seek medical attention. Battery chemicals can cause burns or other health hazards.

Multiple Protection Functions

  1. Anti-freeze protection function: The compressor and water spraying motor turn off if the tube temperature is ≤ 2℃ for 20 seconds under cooling mode. Error code E4 will display, and buttons on the control panel (except power) will be inactive. Protection is relieved when the tube temperature reaches ≥ 8°C, and the compressor applies a 3-minute delay protection.
  2. Water-full safety alarm and shut-off protection function: Warning sounds when the water tank is full. The water-full indicator and "FL" on the LED display will flash. Drain the condensate to allow the unit to recover operation. Refer to "Drainage Instruction" for details.
  3. Delay protection function of compressor: The unit has a 3-minute start delay for the compressor after it is shut down, except for the initial startup.

Handling and Transportation

1. Handle and move the unit

Hold the top of the air outlet window in the front panel with one hand and the handle at the top of the back panel with the other hand. Move the unit in an upright position.

Note:

Drain the water in the unit completely to prevent water leakage and wet the floor or carpet before handling or moving the unit.

Take away the remote control before handling or moving the unit.

Diagrams illustrate the correct handling positions.

Installation & Adjustment

1. Installation

Warning:

1.1 Installation of exhaust hose assembly and its adapter

  1. Take out the exhaust hose assembly and its adapter from the plastic bag.
  2. Extend the exhaust hose at one end and screw the round end of the adapter into the exhaust hose counterclockwise.
  3. Note: Screw the adapter into the correct position, at least 3 turns, to ensure a good connection.

1.2 Installation of the exhaust hose assembly into unit

  1. Determine the window seal-plate position: vertical or horizontal.
  2. If the window seal-plate is horizontal, the slant panel A of the adapter should be upwards.
  3. If the window seal-plate is vertical and on the left side of the window, the slant panel A of the adapter should be to the right.
  4. If the window seal-plate is vertical and on the right side of the window, the slant panel A of the adapter should be to the left.

Diagrams show how to connect the exhaust hose assembly to the unit.

1.3 Installation of window seal-plate

  1. Open the window in half and place the seal-plate into the window, determining its vertical or horizontal position according to the window opening direction.
  2. Extend the seal plate parts, adjust them to the window length, and fix them with screws.

Remarks:

1.4 Installation of the unit

  1. Move the unit with its exhaust hose assembly in front of the window, keeping the unit at least 50cm away from walls or other objects.
  2. Install the rectangular end of the exhaust hose adapter into the corresponding rectangular hole in the window seal-plate assembly, fix it with a screw, and close the window.
  3. Align the 4 openings on the window seal-plate with the 4 openings on the exhaust hose adapter. Set them together, then slide the adapter downwards to lock the two parts securely.
  4. Secure with a self-tapping screw (ø4mm) into the adapter hole.

Remarks:

Important notes:

The exhaust hose is 280mm-1500mm long. Do not use a prolonged or different hose, as this may affect the air conditioner's functions. An obstructed exhaust hose can lead to overheating and tripping of the air conditioner.

Drainage Instruction

1. Manual drain:

When the water tank reaches its alarm level, warning sounds will activate, and the unit will stop working. The water-full indicator and "FL" will flash on the LED display.

  1. Place a tray below the water outlet at the back of the unit.
  2. Unscrew the drain cover and unplug the water stopper to allow water to flow into the tray.
  3. Plug in the stopper and screw the water cover tightly onto the water outlet after drainage.

Notes:

Diagrams show the drain cover, water stopper, and drain hole.

2. Continuous drain:

  1. Unscrew the drain cover and unplug the water stopper.
  2. Connect a ø13mm PVC drain hose to the drain hole, ensuring a snug fit to prevent leakage.
  3. Route the drain hose to a bathroom or outdoor drain.

Notes:

Diagrams show the water stopper, drain hole, and drain cap.

Maintenance and Service

Remark: Turn off the unit and unplug it before performing any maintenance or sending it for service.

1. Surface cleaning

Clean the unit surface with a soft, damp cloth. Do not use chemical solvents like alcohol or gasoline, as they can damage the unit.

2. Filter cleaning

Clean the filter every two weeks. A clogged filter can reduce the unit's performance.

2.1 How to clean filter:

  1. Grip the filter handle and gently pull it out in the direction shown by the arrow.
  2. Notes: Use even force to remove the filter to avoid twisting or damage. Remove filters from the back panel first, then the side panel.
  3. Clean the filters gently in warm water (around 40°C) mixed with detergent, and dry them in the shade.
  4. Notes: Do not squash the mesh. Do not use sharp objects or brushes on the mesh.

2.2 Installation of the filter:

Special note: Install the filters to the side panel first, then the filter into the back panel.

  1. Align the filter end with the slot and gently push the filter into the slot.
  2. Notes: Install the filter in the opposite direction of removal. Install the filter gently to avoid damage.

3. Cleaning of handle position and remote control storage area:

  1. Take out the remote control.
  2. Clean the handle position and remote control storage area with a wet and soft cloth.

Note: Do not drip water into the unit.

End of Season Storage

  1. Unscrew the drain cover and pull out the stopper to drain water completely. (Note: The tilt angle of the unit must be ≤ 30°).
  2. Run the unit in fan mode for half a day to dry the interior completely and prevent mold.
  3. Turn off the unit, unplug it, wrap the power cord around the wire-winding pillar, insert the plug into the universal fixing hole at the back panel, and install the water plug and drain cap.
  4. Remove the heat exhaust hose assembly, clean it, and keep it properly.

Notes:

Note: Ensure the unit is stored in a dry place. All accessories should be protected together.

Troubleshooting

Check the unit and suggestions below before seeking professional service. Never dismantle or repair the unit yourself, as it may cause harm to you and your property.

Trouble Cause Remedy
The unit fails to start up Power supply failure Connect the unit to a live socket and turn it on.
Water-full and its indicator lighting up Drain the water stored in the unit.
Bad cooling effects Ambient temperature too low or too high It is recommended to use this unit between 10-35°C (50-95°F).
The room temperature is lower than the set temperature in cooling mode. Change the set temperature.
There is direct sunlight Close the curtain.
The doors and windows are open, the room is crowded or there are other heat sources Close the door and window, remove other heat sources, and add new air-conditioners.
Dirty filter Clean or replace the filter.
Air inlet or air outlet clogged Remove the obstruction.
High noise level The unit is being placed at uneven surface. Put the unit at a flat and firm place (may reduce noise).
The compressor does not work Initiation of overheat protection. Wait until the temperature decreases; the unit will re-start automatically.
The remote control does not work Too long distance Bring the remote control close to the air-conditioner and ensure it aims at the signal receptor on the unit.
The remote control didn't aim at signal receptor on unit. Ensure the remote control aims at the signal receptor on the unit.

Error Codes:

Appendix

Fuse parameters

Schematic diagram of the air conditioner

A schematic diagram shows the components: Compressor, Condenser, Capillary, and Evaporator.

For specific technical parameters of the model, refer to the rating label on the product.

Correct Disposal of this product

This marking indicates that the product should not be disposed of with other household wastes throughout the EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return your used device, please use the return and collection systems or contact the retailer where the product was purchased. They can take this product for environmentally safe recycling.

Models: 048-GM-48266, 048-GM-48266 Portable Air Conditioner, Portable Air Conditioner, Air Conditioner

File Info : application/pdf, 18 Pages, 2.12MB

PDF preview unavailable. Download the PDF instead.

DELLA 048-GM-48266 (01)

References

Related Documents

Preview DELLA 14K BTU Portable Air Conditioner User Manual
User manual for the DELLA 14K BTU Portable Air Conditioner, covering safety instructions, installation, operation, maintenance, troubleshooting, and warranty information.
Preview DELLA 14000 BTU Portable Air Conditioner User Manual
User manual for the DELLA 14000 BTU Portable Air Conditioner (Model# 048-GM-48265), detailing safety precautions, operation modes (cooling, heating, fan, dehumidifying), installation, Wi-Fi connectivity, maintenance, troubleshooting, and warranty information.
Preview DELLA Mobile Air Conditioner Use and Care Manual 048-GM-48265
This DELLA Mobile Air Conditioner Use and Care Manual (Part Number: 048-GM-48265) provides comprehensive instructions for installation, operation, maintenance, and troubleshooting of the portable air conditioning unit. Learn about its features, control panel functions, remote control usage, drainage procedures, and safety precautions to ensure optimal performance and longevity.
Preview Della 14000 BTU Portable Air Conditioner User's Manual
Comprehensive user's manual for the Della 14000 BTU Portable Air Conditioner (Model# 048-GM-48265), detailing specifications, installation, operation, maintenance, troubleshooting, and Wi-Fi connectivity.
Preview Della 048-OPAC-9H Portable Air Conditioner Instruction Manual
This instruction manual provides comprehensive guidance for the Della 048-OPAC-9H portable air conditioner, covering installation, operation, safety, maintenance, and troubleshooting procedures.
Preview DELLA Portable Air Conditioner User Manual | PAC10, PAC12, PAC14 Models
Explore the DELLA Portable Air Conditioner User Manual for models PAC10, PAC12, PAC14, and 048-GM-48384. This comprehensive guide covers installation, operation modes (Cool, Heat, Fan, Dry), remote control functions, care, maintenance, and troubleshooting tips to ensure optimal performance and longevity of your portable air conditioning unit.
Preview Della 048-OPAC-9H Portable Air Conditioner User Manual: Setup, Operation & Safety
Get detailed instructions for your Della 048-OPAC-9H portable air conditioner. This manual covers installation, operation modes, safety warnings for R32 refrigerant, maintenance, and troubleshooting.
Preview DELLA Portable Air Conditioner User Manual & Installation Guide
Comprehensive user manual and installation guide for DELLA Portable Air Conditioners (Models 048-TL-PAC10K, 048-TL-PAC12K, 048-TL-PAC14K), covering setup, operation, maintenance, and troubleshooting.