SMC ZL Series Digital Pressure Switch for Energy-Saving Control Ejector

Before Use

Thank you for purchasing the SMC ZL Series with Digital Pressure Switch. Please read the operation manual carefully before operating the product and make sure you understand its capabilities and limitations. Please keep the operation manual handy for future reference.

To obtain the operation manual about this product, please refer to the SMC website (http://www.smcworld.com) or contact SMC directly.

Safety Instructions

These safety instructions are intended to prevent hazardous situations and/or equipment damage. They indicate the level of potential hazard with the labels of "Caution", "Warning" or "Danger". They are all important notes for safety and must be followed in addition to International standards (ISO/IEC) and other safety regulations.

To obtain operating the ejector which is mounted on this product, please refer to "Handling Precautions for SMC Products" for vacuum equipment on our general product catalogue or precaution for each product.

Caution:

Operator error could result in injury or equipment damage.

Warning:

Operator error could result in serious injury or loss of life.

Danger:

In extreme conditions, there is a possibility of serious injury or loss of life.

Operator

This operation manual is intended for those who have knowledge of machinery using pneumatic equipment, and have sufficient knowledge of assembly, operation and maintenance of such equipment. Only those persons are allowed to perform assembly, operation and maintenance. Read and understand this operation manual carefully before assembling, operating or providing maintenance to the product.

Warning Instructions

Caution Instructions

Names and Functions of Product

Installation

Wiring

Connection

Connector

Connecting/Disconnecting:

Pin No. of the Connector (Power supply and output cable for the digital pressure switch and pilot valve)

[Diagram description: A diagram showing connector pins with labels. Specific pin numbers and functions are not detailed in the text, but the context implies standard electrical connections.]

Internal circuit and wiring example

Easy Setting

See below for the energy-saving control operation and the set values which are preset to the switch. If the operation shown below does not cause any problems, keep these settings.

Operation of OUT1

When the pressure exceeds the set value (P_1), the pressure switch turns ON. When the pressure decreases below the set value (P_1) by the hysteresis value (H_1), the switch turns OFF. The default settings are P_1: -70.0 kPa and H_1:10.0 kPa.

Operation of OUT2

Supply pilot valve: OUT2 is turned on by the signal for suction. Suction starts by the generation of vacuum pressure. When the vacuum pressure reaches the set value (P_1), the supply pilot valve turns OFF. After the supply pilot valve is turned off, the vacuum pressure will decrease. When the vacuum pressure drops below (P_1) by the amount set in (P_2), the supply pilot valve will turn on again and increase vacuum pressure. After that, the supply pilot valve will turn ON and OFF repeatably. Default setting is H_2: 5.0 kPa.

*: When turning off the supply pilot valve with a vacuum pressure that is higher than the set value (P_1), and for other setting methods, refer to the operation manual which can be obtained from the SMC website (http://www.smcworld.com).

<How to change the set value>

[Normal output (OUT1)]

  1. Press the [SET] button once in measurement mode.
  2. "P_1" and the set value are displayed alternately.
  3. Press the [UP] or [DOWN] button to change the set value. The [UP] button increases vacuum pressure, and the [DOWN] button decreases it.
    • Press the [UP] button once to increase the value by one digit; press and hold to continuously increase.
    • Press the [DOWN] button once to decrease the value by one digit; press and hold to continuously decrease.
  4. Press the [SET] button to complete the setting of "P_1". The display shows [H_1] and the set value alternately. The [UP] button increases, and the [DOWN] button decreases the set value.
  5. Press the [SET] button to complete the setting of "H_1". The display shows [H_2] and the set value alternately. The [UP] button increases, and the [DOWN] button decreases the set value.
  6. Press the [SET] button to complete the setting.

When the reversed output is changed, the following parameters are displayed, and each set value can be changed using the method shown above.

[Reversed output (OUT1)]

[Description: This section indicates that similar steps apply for reversed output settings, involving changing parameters like P_1, H_1, and H_2.]

Function Setting

Measurement mode

The measurement mode is the condition where the pressure is detected and indicated, and the switch function is operating. This is the basic mode; other modes should be selected for setting changes and other function setting changes.

[Diagram description: A flow diagram showing transition from Measurement mode to Function selection mode by pressing the [UP] button for 2 seconds or longer. From Function selection mode, pressing the [UP] button for 2 seconds or longer returns to Measurement mode.]

Function selection mode

In measurement mode, press the [UP] button for 2 seconds or longer to display [F 0]. Select the function setting to be changed, [Fxx]. Press the [UP] button for 2 seconds or longer in function selection mode to return to measurement mode.

Default setting

The default settings are as follows. Refer to the operation manual on the SMC website (http://www.smcworld.com) when changing the settings.

[F 0] Unit conversion function

Unit specification Default setting
SI unit fixed kPa
Unit conversion function [Value not specified in text, likely a setting option]

[F 1] Setting of OUT1

Item Explanation Default setting
Reversed output Selects which type of switch output is used, normal or reversed. Normal output
Pressure setting Sets the ON or OFF point of the switch output. -70 kPa (P_1)
Hysteresis Setting of hysteresis can prevent chattering. 10 kPa (H_1)

[F 2] Setting of OUT2

Item Explanation Default setting
Supply pilot valve at signal ON Sets the ON point of the supply pilot valve signal. 5 kPa (H_2)
Supply pilot valve at signal OFF Sets the OFF point of the supply pilot valve signal. 0 kPa (H_3)
Set the range in which the supply pilot valve input is prohibited Sets the range where the ON point of the supply pilot valve signal is not allowed to be input. 1 kPa (H_4)

[F 3] to [F99] Setting

Item Default setting
[F 3] Setting of response time 2.5 ms
[F 4] Setting of auto-preset Manual
[F 6] Setting of fine adjustment of display value 0%
[F11] Setting of display resolution 1000-split
[F80] Setting of power saving mode OFF
[F81] Setting of security code OFF
[F90] Setting of all functions OFF
[F96] Checking of suction command condition OFF
[F98] Check of output Normal
[F99] Reset to the default setting OFF

Other Settings

Maintenance

How to reset the product for power cut or forcible de-energizing

The setting of the product will be retained as it was before a power cut or de-energizing. The output condition is also basically recovered to that before a power cut or de-energizing, but may change depending on the operating environment. Therefore, check the safety of the whole system before operating the product.

If the system is using accurate control, wait until it has warmed up (approximately 10 minutes).

[F99] Reset to the default setting

If the setting of the pressure switch becomes unknown, the default setting can be restored.

<Operation>

  1. Press the [UP] or [DOWN] button in function selection mode to display [F99].
  2. Press the [SET] button. Move on to reset to the default setting.
  3. Set the display to [ON] by pressing the [UP] or [DOWN] button, then press the [UP] and [DOWN] buttons simultaneously for 5 seconds or longer.

[Diagram description: A sequence showing the display changing from "OFF" (unused) to "ON" (resetting) and then confirming the reset. The process involves selecting "ON" and holding two buttons.]

All settings are returned to the default values.

Press the [SET] button to confirm selection.

Return to function selection mode.

Setting of [F99] Reset to the default setting completed.

Troubleshooting

Error indication

This function is to display error location and content when a problem or an error occurs.

Error Name Error Display Error Type Troubleshooting Method
Over current Error Erl HHH The switch output load current is more than 80 mA. Turn the power off and remove the cause of the over current. Then turn the power on.
Zero-clear Error E-2 OFF During the zero clear operation, pressure above ±3.5%F.S. has been applied. After 1 second, the mode will return to measurement mode. The zero clear range can vary ±1%F.S. with individual product differences. Perform zero clear operation again after restoring the applied pressure to an atmospheric pressure condition.
Pressurizing Error E-3 LLL Pressure has exceeded the upper limit of the set pressure range. Reset applied pressure to a level within the set pressure range.
System Error Ero, Er4, E-6, E-7, E-8, E-9 OFF Displayed in the case of an internal data error. Turn the power off and turn it on again. If resetting fails, an investigation by SMC Corporation will be required.

If the error cannot be reset after the above measures are taken, please contact SMC.

Specification

Refer to the operation manual on the SMC website (http://www.smcworld.com).

Note: Specifications are subject to change without prior notice and any obligation on the part of the manufacturer.

©2012-2016 SMC Corporation All Rights Reserved

Model Number: ZL3-OM00201A

Models: ZSE10 Digital Pressure Switch Vacuum Compound Pressure, ZSE10, Digital Pressure Switch Vacuum Compound Pressure, Pressure Switch Vacuum Compound Pressure, Vacuum Compound Pressure

File Info : application/pdf, 2 Pages, 984.81KB

PDF preview unavailable. Download the PDF instead.

ZSE10 ZL3 ZL6

References

Microsoft Word 2016 Microsoft Word 2016

Related Documents

Preview SMC High Precision Digital Pressure Switch ISE70G/ISE75G/ISE76G/ISE77G Instruction Manual
This instruction manual provides comprehensive details for the SMC High Precision Digital Pressure Switch series, including models ISE70G, ISE75G, ISE76G, and ISE77G. It covers product specifications, safety instructions, installation procedures, operation modes, maintenance guidelines, and troubleshooting steps for industrial applications.
Preview SMC Pneumatic Recommendations for Efficient and Safe Machine Operation & Energy Saving
Explore SMC's Engineering Aids and Energy Saving Program (Ver.2) for pneumatic systems. Discover recommendations for efficient, safe, and cost-effective machine operation, including leak detection, air preparation, blow guns, and vacuum components.
Preview SMC ZSE40/ISE40 Series High-Precision Digital Pressure Switch
This document provides detailed specifications, features, and operating instructions for the SMC ZSE40 and ISE40 Series high-precision digital pressure switches. It covers product overview, specifications, wiring diagrams, installation, and troubleshooting.
Preview Manual de Funcionamiento: Presostato Digital SMC ZSE30A/ISE30A
Guía completa de operación para el presostato digital SMC ZSE30A(F) e ISE30A. Incluye instrucciones de seguridad, instalación, operación, mantenimiento y especificaciones técnicas para entornos industriales.
Preview SMC HRLE Series Dual/Basic Type Thermochillers for Laser Applications
Detailed specifications and features of the SMC HRLE Series thermochillers, designed for laser applications with dual or basic type configurations. Features include space-saving design, energy efficiency, and precise temperature control.
Preview SMC IITV23 Series Plug-in Electro-Pneumatic Regulator / Manifold Type
Comprehensive technical overview of the SMC IITV23 Series plug-in electro-pneumatic regulator and manifold system, detailing features like PROFINET compatibility, wiring reduction, compact design, specifications, ordering information, and safety precautions for industrial automation.
Preview SMC-PAD User Manual
User manual for the SMC-PAD MIDI Controller, detailing its features, connections, and operation.
Preview SMC Compact Manometer PPA100/PPA101/PPA102 Instruction Manual
Detailed instruction manual for the SMC Compact Manometer series (PPA100, PPA101, PPA102), covering safety, specifications, installation, maintenance, and operation.