Read this user manual carefully before using the product to ensure that you completely understand the product and can correctly use it. After reading this user manual, keep it properly for future reference. Improper use of this product may cause serious injury to yourself or others, or cause product damage and property loss. Once you use this product, it is deemed that you understand, approve and accept all the terms and content in this document. EcoFlow is not liable for any loss caused by the user's failure to use this product in compliance with this user manual. In compliance with laws and regulations, EcoFlow reserves the right to final interpretation of this document and all documents related to this product. This document is subject to changes (updates, revisions, or termination) without prior notice. Please visit EcoFlow's official website to obtain the latest product information.
Technical Specifications
Category | Details |
---|---|
Basic Information | |
Net Weight | 14 kg (31 lbs) |
Dimensions (L W H) | 48 cm 14 cm 30 cm (18.9" x 5.5" x 11.8") |
Wi-Fi | Supported (<120 Meters) |
Bluetooth (v4.0) | Supported (<15 Meters) |
Output Spec | |
AC Output | Pure sine wave, 3600 W (surge 7200 W, 100 ms), 230 V, 50 Hz (Australian Version: 240 V, 50 Hz). Linear derating to 1800 W when 40 (104F) < Ambient Temperature < 60 (140F). Derating to 3000 W when battery voltage < 49 V. |
Maximum AC Output Supported by X-Boost | 5200 W |
DC Output | 13.6 V 70 A, maximum power: 1000 W or 26.4 V 60 A, maximum power: 1600 W |
Input Spec | |
AC Input Power | 3000 W maximum power, 15 A maximum current, supported by EcoFlow X-Stream Technology |
AC Input Voltage | 220240 V, 50 Hz/60 Hz |
PV Input 2/3 | 1560 V 30 A, maximum power: 1600 W |
Alternator Input PV Input 1 | 1360 V 60 A, maximum power: 1000 W |
PV Input 1 | 1560 V 30 A, maximum power: 1600 W |
Battery Port Spec | |
Battery Port (x3) | 40-60 V 100 A, supports up to three 2kWh or 5kWh LFP batteries, which are sold separately. (Not recommended to use one Power Hub with both a 2kWh LFP and 5kWh battery at the same time.) |
Operating Environment | |
Operating Temperature | 25C to 60C (-13F to 140F) |
Storage Temperature | 25C to 60C (-13F to 140F) |
Other | |
EcoFlow Smart Generator | 1800 W maximum charging power, sold separately. |
Safety Instructions
- SAVE THESE INSTRUCTIONS This manual contains important safety and operating instructions.
- Before using battery charger function, read all instructions and cautionary markings on battery charger, battery, and product using battery.
- CAUTION To reduce risk of injury, charge only LiFePO4 type rechargeable batteries. Other types of batteries may burst causing personal injury and damage.
- This is a Safety Class I product (supplied with a protective grounding terminal). Uninterruptible protective grounding must be provided at the AC input and/or output terminals. Alternatively, the grounding point located externally on the product may be used. Whenever it is likely that the grounding protection has been damaged, the product must be turned off and secured against unintended operation; please contact qualified service staff.
- To prevent fire, short circuits, and electric shocks, do not install this product in environments with high humidity, high temperature, or conductive contaminants.
- Before installing this product, disconnect the main power supply. Do not work with live power.
- Keep this product away from heat sources, such as fires or heating furnaces.
- Keep this product away from any liquid. Do not immerse this product in water or get it wet. Do not use this product in rain or humid environments.
- Do not use this product in environments with strong static electricity or magnetic fields.
- Do not disassemble this product in any way or pierce it with sharp objects.
- Do not use wires or other metal objects that may result in a short circuit.
- Do not use unofficial components or accessories. If components or accessories need to be replaced, purchase them from the EcoFlow official sales channels.
- Strictly comply with the ambient temperature for use in this user manual when using this product.
- Do not stack other heavy objects on this product.
- Do not forcibly block the fan during product use or place the product in an unventilated or dusty area.
- Please avoid impact, falls, or severe vibrations when using the product. In case of a severe external impact, turn off the power supply immediately and stop using the product. Ensure the product is well fastened during transportation to avoid vibrations and impacts.
- If the product falls into water accidentally during use, place it in a safe open area and stay away from it until it is completely dry. The dried product cannot be reused, and should be properly disposed according to the method described in the EcoFlow Battery User Manual. If the product catches fire, we recommend that you use the fire extinguishers in the following order: water or water mist, sand, fire blanket, dry powder, and carbon dioxide fire extinguisher.
- If there is dirt on the ports of the product, clean it with a dry cloth.
- Place this product carefully to prevent damage caused by the product falling over. If the product falls over and is seriously damaged, power it off immediately.
- Keep this product out of reach of children and pets.
EcoFlow App
Control, monitor and customize your Power Kits from afar with the EcoFlow App. Download at: https://download.ecoflow.com/app
By using EcoFlow Products, Applications and Services, you consent to the EcoFlow Term of Use and Privacy Policy, which you can access via the "About" section of the "User" page on the EcoFlow App or on the official EcoFlow website at https://www.ecoflow.com/policy/terms-of-use and https://www.ecoflow.com/policy/privacy-policy
Bluetooth of this product can only be connected with one EcoFlow App account. If you need to connect the product through another account, you can reset the Bluetooth through the App or by long pressing the DC button of the product for 3 seconds ⏱️.
Getting Started
System Overview
The EcoFlow Power Hub system diagram illustrates how various components connect to form a complete power solution. The central EcoFlow Power Hub (1) acts as the core, connecting to an AC/DC Smart Distribution Panel (2) and a Power Kit Console (3). It can integrate with EcoFlow 2kWh or 5kWh LFP Batteries (4) and an EcoFlow Smart Generator (5). Power sources include Shore Power/Grid Power (6), Rigid/Flexible Solar Panels (7), Foldable/Portable Solar Panels (8), and a Vehicle Alternator (9). The system powers DC Appliances (3) and AC Appliances (1).
Important Notes:
- If the product is installed in an enclosed space, proper ventilation is a MUST to prevent this product from overheating.
- For safety reasons, it is recommended to install a Ground Fault Circuit Interrupter (GFCI), also known as Residual Current Device (RCD) in the AC input and AC output of the Power Hub. Please refer to local regulations regarding grounding of autonomous power systems.
- Before connecting this product to an EcoFlow LFP Battery, ensure that there is no charging input connected to the Power Hub and the LFP Battery is powered off.
- It is not recommended to use one Power Hub with both 2kWh and 5kWh LFP battery at the same time.
- It is not recommended to connect or disconnect the LFP battery when the system is on.
Product Overview
The EcoFlow Power Hub has a front panel with various ports and indicators. From left to right on the top row: ALT IN / PV IN 1 Port (1), PV IN 2/3 Port (2), Battery 1/2/3 Port / Smart Generator Port (3), AC IN Port (4), and AC OUT Port (5) (specific to region). The front panel also features a Main Power Button (6), DC OUT Button (7), AC OUT Button (8), and indicators for AC Out (9), DC Out (10), AC IN (11), PV IN 2/3 (12), and ALT IN / PV IN 1 (13). The rear or side panel includes RJ45 CAN Bus Ports (14), DC Main OUT Port (15), AC Main OUT Port (16), an Earth Stud (17), an Air Outlet (18), and an Air Inlet (19).
CAN Bus Connection
The CAN Bus connection diagram shows two RJ45 CAN Bus Ports (14) on the Power Hub. It illustrates three scenarios for system communication stability:
- When neither the AC/DC Smart Distribution Panel nor the Power Kit Console is connected, two RJ45 CAN Bus terminators must be connected to the Power Hub's CAN Bus ports.
- When the AC/DC Smart Distribution Panel and the Power Kit Console are connected to the Power Hub, no terminators are needed on the Hub itself (they are assumed to be on the connected devices or not required).
- When either the AC/DC Smart Distribution Panel or the Power Kit Console is connected, one RJ45 CAN Bus terminator must be connected to the Power Hub's remaining CAN Bus port.
Both ports must be connected to stabilize communication throughout the system. Not doing so will cause the system to malfunction.
Product Usage
Power On / Off
Press and hold the Main Power Button (6) for 3 seconds ⏱️ to power on or off. The status indicators (top right) will flash 3 times and then stabilize (on for power on, off for power off). Please wait 5 seconds to let the system completely shut down before further operation after pressing the main power button. Ensure that there is no charging input connected to the Power Hub before shutting down the Power Kits.
DC Output
When the power is on, short press the DC OUT button (7) to enable DC Output. Short press again to disable DC Output. Status: ✅ DC OUT: White light solid; ⚠️ Error: Orange light flashing.
AC Output
When the power is on, short press the AC OUT button (8) to enable AC Output. Short press again to disable AC Output. When the Power Hub is in idle mode, please turn off AC Output to avoid power loss. Status: ✅ AC OUT: White light solid; ⚠️ Error: Orange light flashing.
AC Charging
The EcoFlow Power Hub features EcoFlow fast charging technology X-Stream. The maximum AC charging power is 3000 W and the maximum AC charging current is 15 A. Users can adjust the charging current via EcoFlow App or Power Kit Console. The default charging current is 10 A. EcoFlow is not liable for damages caused by the use of charging cables not provided by EcoFlow. Status: ? Charging: White light flashing; ✅ Fully charged: White light solid; ⚠️ Error: Orange light flashing.
Smart Generator Charging
The Power Kits can be recharged by connecting an EcoFlow Smart Generator. This can be done via DC Charging (connecting the Smart Generator to the Power Hub with the Smart Generator Charging Cable) or AC Charging (connecting the Smart Generator to the Power Hub with the AC Charging Cable). The Smart Generator and charging cable are sold separately.
Solar Charging
The Power Hub has three PV (Photovoltaic) input ports, with a total power of 4800 W for the three ports and 1600 W for each port. PV2/3 ports are dedicated PV input ports, while PV1 can be connected to a vehicle alternator for charging or be used as a PV input port. The maximum input current is 30 A per port. Status: ? Charging: White light flashing; ✅ Fully charged: White light solid; ⚠️ Error: Orange light flashing.
Vehicle Alternator Charging
Users can connect the ALT IN / PV IN 1 Port of the Power Hub and the chassis battery of the vehicle through the alternator charging cable provided by EcoFlow. The Power Hub accepts both 12 V and 24 V alternators, and the maximum charging power is 1000 W. The maximum charging current is 60 A, and the default charging current is 30 A. Users can adjust the charging current via EcoFlow App or Power Kit Console. It is strongly recommended to unplug the alternator charging cable from the Power Hub when the vehicle is not in use for a long time. Status: ? Charging: White light flashing; ✅ Fully charged: White light solid; ⚠️ Error: Orange light flashing.
X-Boost Feature
With EcoFlow X-Boost technology, this product can power a 5200 W Max device (for heating appliances only) while the rated output power remains 3600 W, avoiding operation failure due to overload protection. The X-Boost feature is unavailable when AC Output is in bypass mode and is not suitable for all appliances, particularly those with voltage protection like precision instruments. Its suitability depends on the specific appliance and operating conditions.
Bypass Mode
In Bypass Mode, when the product is connected to external AC and the AC output is enabled, the system uses the external AC power supply as the primary source for AC output. The LFP battery is also charged by this external AC power supply. The diagram shows AC IN flowing to AC OUT and also charging BATTERIES, with PV and Alternator inputs also present.
Inverter Mode
When external AC power is not available, the system enters Inverter Mode. In this mode, AC Output is supplied by the LFP battery. The diagram shows power flowing from BATTERIES to AC OUT, with PV and Alternator inputs available for charging the batteries.
Standby Mode
When DC OUT and AC OUT have no continuous output for 20 seconds, the Power Hub will enter Standby Mode automatically to reduce power consumption and save battery energy. Press the DC OUT or AC OUT button to wake up the system. The Power Hub will not enter Standby Mode during firmware update.
FAQs
1. Can I connect non-ECOFLOW photovoltaic panels?
Yes, the Power hub has three independent PV charging inputs, and users are free to choose any brand and model of PV panel.
2. Which scenarios does this product apply to?
Application scenarios include but are not limited to Homes, RVs, and Off-grid Builds.
3. Do the input and output parameters of this product apply to electricity use standards of all countries?
Yes. Both low-voltage and high-voltage versions of this product are available, which cover electricity use standards of all countries.
4. What are the charging and discharging methods of this product?
Charging methods include: AC Charging, Vehicle Alternator Charging, Smart Generator Charging and Solar Charging. The discharging method is AC/DC output.
5. Which devices can connect to the AC output port of this product?
The rated power of the AC output port of this product is 3600W, and surge power is 7200W. It can supply power to most home appliances. However, it is recommended to confirm the power of the appliances before use, and ensure that the total power of all AC loads is less than the rated power.
6. How can I clean this product?
Use a dry, soft, and clean cloth or paper towel to wipe off dust, dirt, or water on this product.
7. How do I store this product?
Before storage, power off the product, then store it in a dry and well-ventilated indoor environment. Do not place this product near water sources.
What's in the Box
- Power Hub 1
- Solar Charge Cable (6m/20ft) 1
- Mounting Kit (Back) 1
- Mounting Kit (Bottom) 1
- RJ-45 CAN Bus Terminator 2
- M5*20 (7pcs)
- M4*10 (6pcs)
- User Manual 1
- Warranty Card 1
- Quick Start Guide 1
Care and Maintenance
Use or store this product in an environment with a temperature ranging from -25C (-13F) to 60C (140F) and keep this product away from water sources, heat sources, and metal objects. For safety reasons, do not store this product in an environment where the temperature is higher than 45C (113F) or lower than 0C (32F) for a long time.
FCC Statement
This equipment complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This equipment may not cause harmful interference, and (2) this equipment must accept any interference received, including interference that may cause undesired operation.
Warning: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
FCC Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.