Daikin Air Conditioner Controller Operation Manual
Part No.: R08019034482 OM-5RTBR-1209(0)-DAIKIN (DAS)
Before using your air conditioner, please read this operating manual carefully and keep it for future reference.
A. Operating Guide
1. Upon power up of the unit, the LCD displays the main display screen:
2000/01/01 | [Sat] | 12:00am |
Status | : | OFF |
Mode | : | Heating |
Set Temp | : | 24°C |
2. Press the [ON/OFF Button] for 1 second to switch on the unit if the status shows OFF. The status will change to ON. The ON/OFF LED will light up.
3. Press the [COOL Button] for 1 second if cooling is required or the [HEAT Button] if heating is required.
4. The 'Set Temp' refers to temperature setting.
5. Press the [Down Arrow] button once to view the compressor(s) on, off or defrost status.
2000/01/01 | [Sat] | 12:00am |
Compressor 1 | : | ON |
Compressor 2 | : | DEFROST |
6. Press the [Down Arrow] button again to view the temperature for room and outdoor ambient.
2000/01/01 | [Sat] | 12:00am |
Return Air | : | 24.0°C |
Outdoor Air | : | 24.0°C |
7. Press the [Down Arrow] button again to view the selected type for unit, number of compressor used, indoor fan 'always on' option, model and EEPROM version.
2000/01/01 | [Sat] | 12:00am |
Type | : | H/Pump |
No. Comp | : | 2 Comp |
IDF Opt | : | |
Model | : | 5RT90BR_E |
EP.Rev | : | 0.0 |
8. Press the [Up Arrow] button to return to previous screen(s) or [ESC] to return to main screen.
9. Press the [ALARM Button] to view or clear the alarm history. If alarm occurs, contact your dealer or serviceman.
Note: Display diagram is for illustration purpose only. It may differ for different models. The display information shall be subjected to the setting in the main controller board.
B. Main Menu
Changes can be made to the factory setting parameter. This is done in the Main Menu. Press [ENTER] button to go into the Main Menu.
The Main Menu consists of Operation Menu, Settings Menu, Timer Menu, Alarm Menu, Warning Menu and Display Menu.
How to use the Main Menu?
- Press [ENTER] to view the sub-Menu under Main Menu.
- Go to the sub-Menu you want by pressing the [Up Arrow] or [Down Arrow] button. Press [ENTER] to select the sub-Menu.
- Go to the parameter you want to change or view by pressing the [Up Arrow] or [Down Arrow] button. Press [ENTER] to select this parameter.
- Change the parameter by pressing the [Up Arrow] or [Down Arrow] button. Once completed press [ENTER]. Press [ESC] to go back to previous screen until you see the initial display screen.
Operation Menu
This menu enables us to set the unit status (on or off), set the unit operation mode, change the temperature setting, and manually defrost the unit (applicable for heating mode only).
Some basic settings can be done here. Press [Up Arrow] or [Down Arrow] to select the required setting. Then, press [ENTER] to enter the setting mode. Press [Up Arrow] or [Down Arrow] to toggle the setting. Press [ENTER] again to confirm the setting. Press [ESC] to exit to [Main Menu].
Status | : | OFF |
Mode | : | Heating |
Set Temp | : | 24°C |
Manual Defrost |
Settings Menu
This menu enables us to set the parameters for unit operation (requires password entering), user setting, change password, set panel option and unlock panel.
The panel option enables us to set the LCD backlight and contrast, set the alarm buzzer, enable and disable the screen saver and set a screen saver timeout and set the temperature display in °C or °F.
Note: The Set Parameter in the setting menu requires password for any changes to or to view its parameter.
CAUTION: All the password entering must be done by local dealer/serviceman. User is not allowed to change the value of the set parameter as this may cause damage to unit or deter its operation.
Set Parameter | ||
User Setting | ||
Change Password 1 | ||
Change Password 2 | ||
Panel Option | ||
Unlock Panel |
Some advance settings can be found here. Press [Up Arrow] or [Down Arrow] to select the required setting. Then, press [ENTER] to enter the setting mode. Press [Up Arrow] or [Down Arrow] to toggle the setting. Press [ENTER] again to confirm the setting. Press [ESC] to exit to [Main Menu].
Panel Option
Select [Panel Option] in [Settings Menu] and press [ENTER] to go to this menu.
Backlight ON | : | Normal |
Alarm Buzzer | : | ON |
Contrast | : | 50% |
Brightness | : | Medium |
Temp Unit | : | °C |
Idle Pg Timeout | : | 10 m |
Press [Up Arrow] or [Down Arrow] to select the required setting, [ENTER] to enter into the setting. Press [Up Arrow] or [Down Arrow] to select the required option, [ENTER] to select the option. Press [ESC] to exit to [Settings Menu].
Note: Display diagram is for illustration purpose only. It may differ for different models. The display information shall be subjected to the setting in the main controller board.
Timer Menu
Select [Timer Menu] in [Main Menu] and press [ENTER] to go to this menu.
Clock Setting | ||
Date Setting | ||
Timer Schedule | ||
Timer | : | Enable |
All the timer/schedule settings are included in this menu. Press [Up Arrow] or [Down Arrow] to select the required setting. Then, press [ENTER] to enter the setting mode. Press [Up Arrow] or [Down Arrow] to toggle the setting. Press [ENTER] again to confirm the setting. Press [ESC] to exit to [Main Menu].
Clock Setting
Select [Clock Setting] in [Timer Menu] and press [ENTER] to go to this menu.
hh | : | mm |
12 | : | 00 |
Press [Up Arrow] or [Down Arrow] to select the required option. Then, press [ENTER] to enter the setting mode. Press [Up Arrow] or [Down Arrow] to toggle the setting. Press [ENTER] again to confirm the setting. Press [ESC] to exit to [Timer Menu].
Date Setting
Select [Date Setting] in [Timer Menu] and press [ENTER] to go to this menu.
yyyy | / | mm | / | dd |
2000 | / | 01 | / | 01 |
Day | : | [Sat] |
Press [Up Arrow] or [Down Arrow] to select the required option, [ENTER] to select the option. Press [ESC] to exit to [Timer Menu].
Timer Schedule
Select [Timer Schedule] in [Timer Menu] and press [ENTER] to go to this menu.
Timer | ON | OFF |
---|---|---|
Timer 1 | 0800 | 1800 |
Timer 2 | 0800 | 1800 |
Timer 3 | 0800 | 1800 |
This is the 7 days programmable timer schedule menu. There are 3 ON/OFF events in one day. User can choose to set each day (Sunday - Saturday) ON/OFF timer. Before this schedule can function, user needs to set the [Timer] in [Timer Menu] to enable. Press [ESC] to exit to [Timer Menu].
Note: Display diagram is for illustration purpose only. It may differ for different models. The display information shall be subjected to the setting in the main controller board.
Alarm Menu/Warning Menu
Select [Alarm Menu]/[Warning Menu] in [Main Menu] and press [ENTER] to go to this menu.
Show Alarms | ||
Erase All Alarms |
Show Warnings | ||
Erase All Warnings |
This place keeps records for all previous occurred faults/alarms/warnings. User can view or clear these records. The panel can keep up to 20 faults/alarm warning records. Press [ESC] to exit to [Main Menu].
Show Alarms/Show Warnings
Select [Show Alarms]/[Show Warnings] in [Main Menu] and press [ENTER] to go to this menu.
Alarm 1 | ||
Indoor HEX 1 abnormal temp | ||
2000/01/01 | 12:00am |
WARNING 1 | ||
Indoor HEX 1 deice | ||
2000/01/01 | 12:00am |
The record shows: - Alarm/Warning description - Alarm/Warning occurance date - Alarm/Warning occurance time. Besides that, user can erase the alarm/warning record(s) in this menu (password is required). Press [ESC] to exit to [Alarm Menu]/[Warning Menu].
Display Menu
Select [Display Menu] in [Main Menu] and press [ENTER] to go to this menu.
Indoor HEX Sensor | ||
Outdoor HEX Sensor | ||
Discharge Sensor | ||
Solenoid Valve | ||
Comp Run Time |
EXV Opening | ||
Economizer | ||
Filter Check | ||
Control Type | ||
Software Version |
This menu displays indoor heat exchanger sensor(s) temperature, outdoor heat exchanger sensor(s) temperature, discharge sensor(s) temperature, solenoid valve(s) operation status, compressor(s) run time record, EXV opening pulse, economizer operation status (applicable for unit with economizer only), filter checking time, control type and software version. Some of the submenu may require password for entering. Besides that, user can clear the compressor run time record (password is required). Press [ESC] to exit to [Main Menu].
Note: Display diagram is for illustration purpose only. It may differ for different models. The display information shall be subjected to the setting in the main controller board.
C. Installation
When installing the LCD panel to the bracket:
- Step 1: Hook the LCD panel from the bottom first.
- Step 2: Push to fasten the LCD panel to the bracket.
When removing the LCD panel from the bracket:
- Step 1: Remove the LCD panel from the top part first.
- Step 2: Remove the LCD panel.
1. A 3V DC battery is supplied with the LCD. It is used to ensure that the LCD displays real time once the timer is set.
2. The LCD is wired to the main board via CN8 connection.
Manufacturer Information
The manufacturer reserves the right to revise any of the specification and design contain herein at any time without prior notification.
DAIKIN INDUSTRIES, LTD.
Head office:
Umeda Center Bldg., 2-4-12, Nakazaki-Nishi, Kita-ku, Osaka, 530-8323 Japan
Tokyo office:
JR Shinagawa East Bldg., 2-18-1, Konan, Minato-ku, Tokyo, 108-0075 Japan
Website: https://www.daikin.com/global_ac/
File Info : application/pdf, 8 Pages, 281.47KB
DocumentDocumentReferences
Related Documents
![]() |
Daikin SLM9 Wireless Remote Controller Operating Manual Comprehensive operating manual for the Daikin SLM9 wireless remote controller, detailing functions, installation, error codes, and settings for air conditioning systems. Includes troubleshooting and hardware configuration. |
![]() |
Daikin BRC51D64/65 Remote Controller Operating Manual Comprehensive operating manual for the Daikin BRC51D64/65 wired remote controller, detailing functions, settings, error codes, and installation procedures for Daikin air conditioning systems. |
![]() |
Panduan Administrator DAIKIN APP untuk Pengendali Jarak Jauh Seri BRC1H Panduan ini memberikan instruksi terperinci bagi administrator mengenai penggunaan DAIKIN APP untuk mengelola pengendali jarak jauh seri BRC1H, mencakup pengaturan, pemecahan masalah, dan fitur-fitur lanjutan. |
![]() |
Daikin Wired Remote Controller Operating Manual Operating manual for Daikin wired remote controllers (SRC series), covering functions, settings, and error codes for models like SRC-COA and SRC-HPA. |
![]() |
DAIKIN APP at BRC1H Series Wired Remote Controller: Gabay para sa Tagapangasiwa Ang gabay na ito ay nagbibigay ng detalyadong impormasyon sa paggamit ng DAIKIN APP para sa pamamahala ng BRC1H Series wired remote controllers, kabilang ang mga setting, pag-troubleshoot, at mga advanced na feature. |
![]() |
Daikin Factbox 2025: A Global Leader in HVAC Technology Discover the Daikin Factbox 2025, detailing Daikin's global leadership in heating, cooling, ventilation, air purification, and refrigerant technology. Explore their extensive product range, commitment to sustainability, and innovation in HVAC-R solutions for residential, commercial, and industrial applications. |
![]() |
คู่มือผู้ใช้และติดตั้งรีโมทคอนโทรล Daikin BRC1H และแอป Daikin คู่มือนี้ให้คำแนะนำที่ครอบคลุมสำหรับรีโมทคอนโทรลแบบต่อสาย Daikin BRC1H และแอป Daikin ที่เกี่ยวข้อง เหมาะสำหรับผู้ดูแลระบบและผู้ติดตั้ง ครอบคลุมการติดตั้ง การใช้งาน การตั้งค่า และการแก้ไขปัญหาสำหรับการจัดการเครื่องปรับอากาศอย่างมีประสิทธิภาพ |
![]() |
Daikin BRC1E63 Wired Remote Controller Operation Manual This operation manual provides comprehensive guidance for the Daikin BRC1E63 wired remote controller, detailing its functions, safety precautions, and energy-saving features for Daikin air conditioning systems. |