Mitsubishi Lossnay Ventilator

Operating Instructions

Models: VL-100U5-E (pull cord Type), VL-100EU5-E (wall switch Type)

Safety Precautions

Hazards created by mishandling and their severity are indicated by the following markers:

[!] Warning: This applies to mishandling or misoperation of the product which could lead to a fatal or serious injury.

[Caution] This applies to mishandling or misoperation of the product which will lead to an injury or damage to your home, household effects, etc.

[?] Prohibited

[!] Warning

[Caution]

[?] Prohibited

[➡️ Follow Instructions]

*¹ Refers only to VL-100U5-E (Lossnay with plug-in power cord).

When Using the Unit

When running in winter, the Lossnay transfers the heat of indoor air to the cold outdoor air as it brings outside air in. This means that when outside air is colder than about -10°C, condensation or frost may form on the panel or inside the unit. Since condensation and frost formation varies with subtle changes in conditions (indoor humidity, air flow and the like), switch operating modes or temporarily stop the unit as conditions dictate.

Check that the unit is mounted properly before using it.

Obey the following cautions when using the Lossnay

Mitsubishi recommends mounting the Lossnay away from the bed. If the unit is too close, you may hear operating noise or feel cold air blowing while in bed.

Bugs smaller than the grate openings of the outdoor hood may be able to infiltrate the unit.

The motor and the air filter require periodic maintenance (replacement). Replacement time will vary with frequency of use.

Clearance Diagram Description: Ensure a minimum clearance of 5 cm around the unit, with nothing obstructing the front, and a minimum clearance of 10 cm below the unit.

Features

The Lossnay ventilator, from Mitsubishi Electric, moves dirty indoor air outside (exhausting it) and brings clean air from the outside in (providing air supply). When it supplies air, it brings outside air close to room temperature, functioning as a heat exchanger.

The Lossnay is not an air-conditioner; it is a ventilating fan that exchanges heat as it ventilates. Since it not only sends indoor air out but also brings fresh air in, it works well in tightly sealed homes. As a heat exchanger, it provides heating and cooling at a lower cost than ventilators that merely exhaust.

Built-in filters reduce the amount of dust, pollen, and other particles entering the house in outside air.

To prevent freezing or damage to the Lossnay Core, stop the unit if the outside temperature falls below -10°C and the room's humidity rises above 40%. (The other conditions about temperature and humidity are based on Table 1 as a reference.)

Table 1: Conditions for Preventing Freezing/Damage

Outside temperature (°C) -10 -15 -20 -25
Indoors Temperature (°C) 20 20 20 15
Indoors Humidity (%) 40 35 30 30

Names of Parts

The unit includes the following parts:

Before You Start the Lossnay

Preparing to Turn the Power On

  1. Turn the circuit breaker on at the distribution board. (Diagram shows a circuit breaker in an 'ON' position.)
  2. Insert the power plug into the wall outlet (VL-100U5-E only). (Diagram shows a power plug being inserted into a wall outlet.)

Operation

Note: In the following cases, stop the Lossnay and manually move the shutter knob to the leftmost position (the closed position) to close the shutter:

1. Slide the shutter knob to the open position. (Diagram shows the shutter knob with 'Open' and 'Close' positions indicated.)

Note: Make sure that the shutter knob is located in the open position, and then operate the unit.

For VL-100U5-E

2. Switching operating modes (airflow): Pull the cord to switch from HI to LO to Off. (Diagram shows pull cord operation: HI operation, LO operation with indicator light, Off with indicator light out.)

If Cold Air is Blowing on You

If cold air is blowing directly on you, flip the louver toward you to change the direction of air flow from vertical to horizontal. (Diagram illustrates airflow direction change by adjusting the louver from vertical to horizontal.)

For VL-100EU5-E

2. Using the control switches: (Diagram shows control switches: a Power switch (On-Off) and an Airflow switch (Hi-Lo fan speed).)

* The switches shown above are only an example. Operations and indicators may vary depending on the switches installed.

Maintenance

To maximize the life of the Lossnay, clean off any accumulated dirt and dust on the exhaust air filter and outside air filter at least once every six months.

Warning: Always shut off circuit breakers or, for the VL-100U5-E, remove the power plug from the wall outlet before performing maintenance work. Electric shock and burns could result if power is flowing.

Caution: Wear gloves when maintaining the unit. Failure to wear gloves could result in injury. If using a step-ladder, be sure to place it on level ground where there is nothing underfoot. Injury could result from falling over.

Removing and Cleaning Filters and the Lossnay Core

  1. Turn the power off: 1) Turn the Lossnay off. 2) Always shut off circuit breakers or, for the VL-100U5-E, remove the power plug from the wall outlet. (Diagram shows power plug and breaker.)
  2. Open the panel: Firmly open it all the way. (Diagram shows opening the panel.)
  3. Remove the Lossnay Core: Press the prong of the Lossnay Core's handle and pull the handle toward you to remove the core. (Diagram shows how to press the prong and pull the handle.)
  4. Remove the outside air filter: 1) Pressing on the filter frame prong, pull the filter toward you to remove the filter frame from the main unit. 2) Remove the outside air filter from its filter frame. (Diagram shows filter frame prong and filter removal.)
  5. Cleaning:
    • Cleaning the outside air filter: Remove the dust with a vacuum cleaner. (Diagram shows vacuum cleaner cleaning the filter.) When the filter is heavily soiled, press and wash the filter with cold or warm water (40°C or less), and then air-dry the filter.

Note: Do not wash the filter with hot water, by rubbing or scrubbing, or squeeze or twist the filter, as it can be distorted.

Replacement: The filter is a consumable part. We recommend replacing the filter with the replacement filter (P-100F5-E) after you have washed the filter four times.

Cleaning the exhaust air filter: Use a vacuum cleaner to remove dust. (Diagram shows vacuum cleaner cleaning the exhaust air filter.)

Note: Do not press wires, screwdrivers or hard vacuum cleaner nozzles into the surface of the exhaust air filter. (Doing so may damage the filter.)

Cleaning the Lossnay Core: Clean the Lossnay Core at least once a year. Use a vacuum cleaner to remove surface dust. Vacuum the surface gently with the vacuum cleaner nozzle. (Diagram shows vacuum cleaner cleaning the Lossnay Core.)

Note: Do not expose the Lossnay Core to water, chemicals, or volatile solutions. Do not expose the Lossnay Core close to open flames.

6. Reassembly and Checking After Maintenance

Mount the filter and Lossnay Core by the opposite of the removal procedure.

Caution: After maintenance, reattach parts securely. Injury could result if the unit falls.

  1. Mount the outside air filter: Place the outside air filter into the filter frame and mount it in the main unit. (Do not confuse the top and bottom.)
  2. Mount the Lossnay Core:
    1. Hang the center of the lower part of the Lossnay Core onto the catch on the main unit. (Diagram shows hanging the lower part of the core onto the main unit catch.)
    2. Press the top of the core handle into the main unit until you hear a click. (Diagram shows pressing the top of the core handle.)

    Note: Make sure that the center catches on the top and bottom of the handle and the two ends of the core are inserted all the way in.

3. Close the panel. Swing the panel closed until you hear a click.

4. Turn on the circuit breaker or, for the VL-100U5-E, plug the power plug into the wall outlet.

5. Turn the power on.

6. After reassembly, check the following:

Cleaning the Panel/Main Unit

If the panel or main unit becomes dirty, wipe it with a well-wrung cloth soaked in a solution of neutral detergent and lukewarm water (40°C or less), then wipe it with a clean cloth to remove any traces of detergent.

Note: Use of any of the following solvents in maintenance may warp, weaken or discolor Lossnay components: Paint thinner, alcohol, benzene, gasoline, kerosene, aerosol sprays, alkaline cleaners, chemical wipes, or abrasive-containing detergents, such as cleansers. Clean any dust off of the plug (VL-100U5-E only).

Troubleshooting

Inspect the unit if any of the following problems occurs. If the problem is not listed below, or the problem persists after inspection, shut off the circuit breaker on the distribution board or, for VL-100U5-E, remove the power plug from the wall outlet, and then contact your dealer.

Model Problem Cause Check the following Page
Unit does not operate. No power to main unit. Check the power plug. (VL-100U5-E only)
Check whether a breaker has tripped.
Check whether a power failure has occurred.
4
The unit is louder. The unit is noisy. The panel or outside air filter is not attached securely.
The outside air filter or exhaust air filter is clogged.
Reattach the panel or filter.
Clean the filter.
7
6
It is cold and the shutter will not move. The outside air temperature, indoor air temperature and humidity may have caused the shutter to freeze in place. Shut the Lossnay off until outside temperatures rise, and then resume operation. --
VL-100U5-E
VL-100EU5-E
Less air than normal is coming from the unit. The outside air filter or exhaust air filter is clogged. Clean the filter. 6
The incoming air feels cold. The outside air temperature has dropped. Turn the unit off temporarily and close the shutter, as dictated by the situation. Alternatively, change the louver direction. 5
No air is coming from the unit. Not much air is coming from the unit. The Lossnay is a heat-exchanging ventilator, so the volume of air will be lower than with an ordinary fan. This is normal. -- --
The unit is loud. The shutter is closed. Open the shutter. 5
The panel will not close. The Lossnay Core or outside air filter is not mounted correctly. (A component is out of position or inserted backwards.) Mounted the component correctly. 7
VL-100EU5-E The operation does not match the wall switch. The wiring is incorrect. Contact your dealer. --

Specifications

Model Supply voltage (V) Frequency (Hz) Notch Power consumption (W) Air volume (m³/hr) Temperature exchange efficiency (%) Noise (dB) Weight (kg)
VL-100U5-E 220 50 HI 30 100 73 36.5 7.5
LO 13 55 80 24
230 50 HI 31 105 73 37
LO 15 60 80 25
VL-100EU5-E 240 50 HI 34 106 72 38 7.5
LO 17 61 79 27
220 60 HI 34 103 73 38
LO 17 57 80 25

* Noise values may be higher than those listed depending on the structure of the room.

After-Sales Servicing

Consult with your dealer about the after-sales services provided for this Lossnay product.

If you hear strange sounds, if no air is blown out or if some other trouble occurs, switch off the power and contact your dealer. Consult with your dealer concerning the cost of inspection or repair work.

Disposal Information

Note: This symbol mark is for EU countries only.

This symbol means that electrical and electronic equipment, batteries and accumulators, at their end-of-life, should be disposed of separately from your household waste.

If a chemical symbol is printed beneath the symbol shown above, this chemical symbol means that the battery or accumulator contains a heavy metal at a certain concentration. This will be indicated as follows: Hg: mercury (0.0005%), Cd: cadmium (0.002%), Pb: lead (0.004%).

In the European Union there are separate collection systems for used electrical and electronic products, batteries and accumulators. Please, dispose of this equipment, batteries and accumulators correctly at your local community waste collection/recycling centre. Please, help us to conserve the environment we live in!

Similar disposal information is provided in multiple languages within the original document.

Models: VL-100U5-E pull cord Type, VL-100EU5-E wall switch Type, VL-100U5-E Series Lossnay Ventilator, VL-100U5-E Series, Lossnay Ventilator, Ventilator

File Info : application/pdf, 16 Pages, 6.16MB

PDF preview unavailable. Download the PDF instead.

OPERATING-MANUAL-VL-100 GPL Ghostscript 9.55.0 Adobe Acrobat Standard 2017 17.11.30207

Related Documents

Preview Mitsubishi Electric Lossnay VL-100U5-E / VL-100EU5-E Ventilation Unit User Manual
Comprehensive user manual for Mitsubishi Electric Lossnay ventilation units, models VL-100U5-E and VL-100EU5-E. Covers safety precautions, operation, maintenance, troubleshooting, specifications, and parts catalog.
Preview Mitsubishi Electric Lossnay: Energy-Efficient Ventilation Systems
Explore Mitsubishi Electric's Lossnay range of Heat Recovery Ventilation (HRV) systems, designed for superior Indoor Air Quality (IAQ) and energy efficiency in residential and commercial applications. Discover features, specifications, and control solutions.
Preview Mitsubishi Electric Lossnay P-RCC-E RC Cover Installation Manual
Official installation manual for the Mitsubishi Electric Lossnay P-RCC-E RC Cover, detailing installation procedures, safety precautions, and specifications for residential heat recovery ventilation systems.
Preview Mitsubishi Electric Vertical Lossnay VL-250 Embodied Carbon Calculation
Details the embodied carbon calculation for the Mitsubishi Electric Vertical Lossnay VL-250 heat recovery ventilation unit, following the TM65 ANZ local addendum by CIBSE. Includes product information and carbon breakdown.
Preview Mitsubishi Electric LOSSNAY Ventilation Systems: ERV and HRV Solutions
Explore Mitsubishi Electric's LOSSNAY lineup, featuring Energy Recovery Ventilation (ERV) and Heat Recovery Ventilation (HRV) systems designed to optimize indoor air quality and energy efficiency for commercial and residential applications. Discover product details, specifications, and installation guidance.
Preview Mitsubishi Lossnay Ventilator Operating Instructions for PZ-RF9 Series
Operating instructions and maintenance guide for Mitsubishi Lossnay Energy Recovery Ventilator models PZ-50RF9-E, PZ-65RF9-E, PZ-80RF9-E, and PZ-100RF9-E. Includes safety precautions, filter maintenance, and assembly instructions.
Preview Mitsubishi Lossnay Energy Recovery Ventilator Operating Instructions
Operating instructions for Mitsubishi Lossnay Energy Recovery Ventilator models LGH-F300RVX2-E through LGH-F1200RVX2-E, covering safety precautions, parts identification, operation modes, maintenance, and specifications.
Preview Mitsubishi Electric Plug and Play CO2 Sensors PZ-70CS(W)(D)-E for Enhanced Indoor Air Quality
Mitsubishi Electric PZ-70CS(W)(D)-E CO2 sensors integrate with Lossnay LGH-RVX3 and LGH-RVS systems to automatically adjust airflow for optimal indoor air quality. Features include intuitive airflow control, flexible configuration, traffic light CO2 indicator, hassle-free installation, and consistent results through automatic recalibration.