Connected Switch (with Dimmer Option) Without Neutral
Model Numbers: 7 525 84A, 7 526 84A, 7 527 84A, 7 528 84A, 7 529 84A
Product Overview
This pack contains a connected accessory that requires the installation of the Valena Allure with Netatmo connected starter pack. It is designed to control lighting points and offers dimmer functionality.
Pack Contents:
- Connected switch (with dimmer option) + bleeder
- Site protection
The site protection component operates on frequency bands: 2.4 - 2.4835 GHz with a power level: < 100 mW.
Characteristics
In default mode (on/off), this switch is compatible with various bulb types. For dimmer operation, specific bulb types are required.
Conditions | Wire Gauge | LED | Incandescent/Halogen | ||
---|---|---|---|---|---|
Max. | Min. | Max. | Min. | ||
240 V~ | 2 x 1.5 mm² | 125 W | 5 W | 125 VA | 5 VA |
1 x 2.5 mm² | 75 W | 5 W | 75 VA | 5 VA | |
110 V~ | 2 x 1.5 mm² | 125 W | 5 W | 125 VA | 5 VA |
1 x 2.5 mm² | 75 W | 5 W | 75 VA | 5 VA |
Note: For comfortable lighting, a maximum of 10 bulbs per circuit is recommended, using bulbs of the same type and manufacturer.
Compatibility Warning: Product is NOT COMPATIBLE with ferromagnetic transformers, which may cause product breaking.
Dimmer Mode Operation: When activated via the App, this switch functions only with dimmable bulbs, identifiable by the [Dimmable] logo on packaging.
Bleeder Requirements
The bleeder (ref 040149) must be used systematically to avoid flash ghost effects when the load is OFF.
Bleeder Specifications:
- Voltage: 110-240 V~
- Frequency: 50/60 Hz
- Current: 11 mA max.
- Temperature Range: -5°C to +55°C
Usage: Only one bleeder is required per circuit.
Before Starting: Wiring Precautions
If planning to install two-way light switches or switched power outlets, read the following precautions:
To control a light with two or more switches, only use the following product combinations:
- Scenario 1: Connected switch (with dimmer option) + bleeder (x1)
- Scenario 2: Wireless light switches for all other controls (not included in this pack).
Important: Do not use two connected switches (with dimmer option) to control the same lighting point.
Mandatory Safety Precautions
- OFF
Switch off the power at the main circuit breaker.
Make sure that the power is off before continuing with the installation.
Visual representation: Two steps with warning icons (⚠️) indicating to switch off power at the breaker and verify power is off.
Installation Procedure
Follow these steps to install the connected switch:
- Uninstall the old switch.
- Wire the connected switch.
- Install the switch.
Visual representation: Illustrations showing the steps: uninstalling the old switch, wiring the new switch, and mounting the switch.
Wiring Details
Wire Identification:
- N (neutral) = blue wire
- L (Live) = all wires except blue and green/yellow
- Earth = green/yellow wire
To ensure correct operation of the connected switch (with dimmer option), the bleeder must be wired as close to the load as possible. A bulb should be inserted before turning the power on.
The connected switch (with dimmer option) works with standard bulbs or dimmable bulbs, including LEDs over 5 W. Using dimmable LEDs is mandatory when dimmer mode is activated.
Existing Wiring Scenarios
Replacement of an existing 2-way switch by a connected switch + wireless light switch
This scenario involves replacing a previous 2-way switch with a wireless light switch, and connecting the wired connected switch.
Use a connector to join all 3 wires together (travellers 1 and 2, and lamp return wire). Use a dedicated connector to insulate the neutral wire, if present.
Visual representation: Wiring diagram showing a wireless switch and a connected switch replacing a 2-way switch setup.
Replacement of a 2-way switch by a connected switch + mechanical push-button
This scenario involves replacing a previous 2-way switch with a mechanical push-button, and connecting the wired connected switch.
Option: Control through mechanical push buttons (maximum of 2). The maximum cable length for push buttons is 50 m.
Visual representation: Wiring diagram showing a mechanical push-button and a connected switch replacing a 2-way switch setup.
Adding a Connected Product
To add a connected product to your installation, follow the instructions:
- In the Legrand Home + Control application (Settings/Add a new product section).
- Or consult the user manual on legrand.com.
Visual representation: A PDF icon linking to www.legrand.com.
Safety Instructions
This product should be installed in compliance with installation rules, preferably by a qualified electrician. Incorrect installation and/or incorrect use can lead to risk of electric shock or fire. Before carrying out the installation, read the instructions and take account of the product's specific mounting location. Do not open up, dismantle, alter or modify the device except where specifically required to do so by the instructions. All Legrand products must be opened and repaired exclusively by personnel trained and approved by Legrand. Any unauthorised opening or repair completely cancels all liabilities and the rights to replacement and guarantees. Use only Legrand brand accessories.
Simplified EU Declaration of Conformity
The undersigned, Legrand, declares that the radio-electric equipment referred to in these instructions complies with directive 2014/53/EU. The full text of the EU declaration of conformity is available on the following website: www.legrandoc.com.