Purpose

These suggestions provide guidelines for the use of Anaco HUSKY® HD 2000 Coupling for joining No-Hub pipe and fittings in accordance with accepted industry standards and practices. All construction projects involve many variables. Governing codes, engineering criteria, and the conventions of the plumbing trade necessitate that judgment decisions must be a combination of design and “on the job” considerations. The following suggestions for joining No-Hub pipe and fittings with the Anaco Husky HD 2000 coupling are not definitive but it is hoped that they will be helpful.

Installation Instructions

A properly calibrated torque wrench set at 80-inch pounds to accommodate the 5/16" hex head screw should always be used when installing HUSKY® HD 2000 couplings. When power tools are used to install HUSKY couplings they should be adjusted or calibrated to torque only to 80-inch pounds.

  1. In order to provide a sound joint with field cut lengths of pipe, the ends should be cut square. Place the neoprene gasket on the end of one pipe and the stainless steel clamp assembly on the other end of the other pipe or fitting to be joined.
  2. Firmly seat both ends of the pipe/fittings against the internally molded shoulder in the center of the gasket.
  3. Slide the clamp assembly into position centered over the gasket.
  4. HUSKY HD 2000 couplings 1.5", 2", 3" and 4" are three inches wide and have four sealing bands. Tighten bands to 80-inch pounds in the following sequence. Starting on the side of the joint with the smaller OD (see diagram “A”) torque as follows: 2, 1 - 2,1 - 3,4 - 3,4 - 2,1 - 3,4
  5. HUSKY HD 2000 couplings 5"-10" are four inches wide, 12” and 15" are 5½" wide and have six sealing bands. Tighten bands to 80-inch pounds in the following sequence. Starting on the side of the joint with the smaller OD (see diagram “B”) torque as follows: 3,21 - 3,2,1 - 4,5,6 - 4,5,6 - 2,1 - 4,5,6.
  6. Typically, once the coupling is installed and torqued to 80-inch pounds in this torque pattern, this is all that is necessary. Couplings may be re-torqued to confirm that all bands have been properly torqued to 80-inch pounds, following the proper torque pattern. Use caution as multiple torquing events may result in clamp failure.

Diagram A: Illustrates torque sequence for 1-1/2" thru 4" couplings.

Diagram B: Illustrates torque sequence for 5" thru 10" couplings.

Bracing

Horizontal pipe and fittings five inches and larger must be suitably braced to prevent horizontal movement. This must be done at every branch opening or change of direction by the use of braces, blocks, rodding or other suitable method to prevent movement or joint separation. (Chapter IV, Handbook of Cast Iron Soil Pipe Institute).

Product Identification

Anaco has intentionally color coated the HUSKY® HD 2000 304 Stainless Steel Shield. The white shield identifies this product as a genuine Anaco HUSKY HD 2000 Heavy-Duty coupling. HUSKY's performance, including its exceptional sealing ability, corrosion resistance, deflection and rigidity has not been compromised in any way.

Models: HD 2000 Heavy Duty No Hub Coupling, HD 2000, Heavy Duty No Hub Coupling, Duty No Hub Coupling, Hub Coupling, Coupling

File Info : application/pdf, 1 Pages, 995.13KB

PDF preview unavailable. Download the PDF instead.

husky hd2000 install ?v=1702416895

References

Adobe PDF library 17.00 Adobe Illustrator 27.7 (Windows)

Related Documents

Preview Husky SD 4000 Couplings: Heavy-Duty Stainless Steel Pipe Couplings
An overview of Husky SD 4000 couplings, detailing their heavy-duty stainless steel construction, applications, product variations, and certifications. Includes a size and torque chart.
Preview Husky 2000 Lumens Rechargeable LED Work Light (EL2206) - Use and Care Guide
Comprehensive use and care guide for the Husky 2000 Lumens Rechargeable LED Work Light (Model EL2206). Includes safety instructions, specifications, operation, charging, and maintenance details.
Preview Husky Micrometer Adjustable Torque Wrench Operating Instructions and Calibration Guide
Comprehensive operating instructions, adjustment guide, and warranty details for Husky Micrometer Adjustable Torque Wrenches. Includes model numbers 625319, 564394, 564464, 1000788224, 1000788225, 1000788226. Learn how to properly apply torque, set desired values, and use extensions with this durable tool.
Preview Husky Swivel Safe-T-Break® Combo: Installation, Maintenance, and Inspection Guide
Comprehensive guide for installing, maintaining, and inspecting the Husky Swivel Safe-T-Break® Combo. Includes safety warnings, operational procedures, and warranty information for fuel dispensing equipment.
Preview Husky 120-Volt Inflator Use and Care Guide
This guide provides instructions for the safe and effective use and care of the Husky 120-Volt Inflator (Model #H120N). It includes safety precautions, operating instructions for inflating tires and other items, maintenance, troubleshooting, and recommended tire pressures.
Preview Husky 3-Shelf Storage Rack Assembly, Use, and Care Guide
This document provides assembly instructions, safety warnings, parts list, and care information for the Husky 3-Shelf Storage Rack. It includes model numbers N2W652454W3B and N2W652454W3R, dimensions, and contact details for support.
Preview Husky Supplier Quick Reference: Common Drawing Features and Manufacturing Practices
A comprehensive quick reference guide for Husky suppliers, detailing common drawing features and manufacturing practices. This document complements drawings by providing essential specifications for various features, including metric and inch threads, counterbore holes, countersink holes, clearance holes, and pipe threads. It serves as a vital resource for ensuring manufacturing accuracy and adherence to industry standards.
Preview Husky UltraShot Injection System Hot Runner Service Manual
This service manual provides detailed instructions for the installation, removal, maintenance, and safe operation of the Husky UltraShot Injection System hot runner. It includes technical specifications, safety warnings, and troubleshooting guidance for industrial injection molding applications.