SICK S300 S30B-2011CA Safety Laser Scanner
Product Data Sheet
Product Overview
The SICK S300 S30B-2011CA is a safety laser scanner designed for industrial applications, providing reliable detection of hazardous areas to ensure personnel safety. It offers advanced features for machine safety and process control.
Brand: SICK
Product Type: Safety Laser Scanner
Model: S30B-2011CA / S300
Description: A yellow and black industrial safety device featuring a rotating sensor head for scanning a protective field.
Ordering Information
Subproduct Family | Version | Scanning Angle | Safety Field Range | Number of Fields | Type | Article Number |
---|---|---|---|---|---|---|
S300 Advanced | Sensor without system connector | 270° | 2 m | 12 | S30B-2011CA | 1026821 |
Note: The system connector must be ordered separately. Refer to "Accessories, connectors, and cables" for details. More device versions and accessories are available at www.sick.com/S300.
Detailed Technical Specifications
Features
Subproduct Family | S300 Advanced |
Version | Sensor without system connector |
Application Area | Indoor |
Safety Field Range | 2 m |
Warning Field Range | 8 m (at 15% remission) |
Distance Measuring Range | 30 m |
Field Set Type | Triple field sets |
Number of Field Sets | 4 |
Number of Fields | 12 |
Number of Monitoring Situations | 4 |
Scanning Angle | 270° |
Resolution (configurable) | 30 mm, 40 mm, 50 mm, 70 mm |
Angular Resolution | 0.5° |
Response Time | 80 ms 1) |
Safety Field Offset | 100 mm |
Number of Multiple Evaluations | 2...16, Configurable |
Automatic Reset Delay | 2 s ... 60 s, Configurable |
1) Dependent on base response time and multiple evaluation.
Safety-Related Characteristics
Type | Type 3 (IEC 61496) |
Safety Integrity Level | SIL 2 (IEC 61508) |
Functional Characteristics
Category | Category 3 (EN ISO 13849) |
Performance Level | PL d (EN ISO 13849) |
PFHD (Average probability of dangerous failure per hour) | 8.0 x 10-8 |
TM (Service life) | 20 years (EN ISO 13849) |
Safe state in case of fault | At least one OSSD is in the OFF state. |
Function | Status |
---|---|
Restart Interlock | ✔ |
Contactor Monitoring (EDM) | ✔ |
Multiple Evaluation | ✔ |
Monitoring Situation Switching | ✔ |
Static Safety Field Switching | ✔ |
Contour as Reference | ✔ |
Integrated Configuration Memory | ✔ |
Measurement Data Output | Via RS-422 |
Safe SICK Device Communication via EFI | ✔ |
Interfaces
Connection Type | System connector with or without connection cable |
Universal I/Os | 5 1) |
Inputs |
|
Outputs |
|
Configuration Type | PC with CDS (Configuration and Diagnostic Software) |
Configuration and Diagnostic Software | RS-232 |
Transmission Speed | 38.4 kBaud |
Data Protocol | RS-422 |
Transmission Speed | ≤ 500 kBaud |
Safe SICK Device Communication via EFI |
|
1) Freely programmable, e.g., for inputting safety control, reset input, contamination warnings, reset required.
2) Availability depends on the configuration of universal I/Os.
3) In combination with an EFI device (Flexi Soft or EFI gateway), five static controller inputs are available. Otherwise two.
4) Freely programmable, e.g., for warning field, contamination, reset required.
Electrical Data
Protection Class | II (EN 50178, EN 60950) |
Supply Voltage Uy | 24 V DC (16.8 V DC ... 30 V DC) |
Current Consumption | 0.33 A 1), 1.7 A 2) |
Outputs |
|
1) At 24 V DC without output load.
2) At 24 V DC with maximum output load.
3) Freely programmable, e.g., for warning field, contamination, reset required.
Mechanical Data
Dimensions (W x H x D) | 102 mm x 152 mm x 106 mm |
Weight | 1.2 kg |
Housing Material | Die-cast aluminum |
Housing Color | RAL 1021 (Canary yellow) |
Optical Cover Material | Polycarbonate |
Optical Cover Surface | Exterior with scratch-resistant coating |
Environmental Data
Insulation Class | IP65 (EN 60529) |
Operating Temperature | -10 °C ... +50 °C |
Storage Temperature | -25 °C ... +50 °C |
Shock Resistance | IEC 60068-2-6, IEC 60068-2-64, IEC 60721-3-5, IEC TR 60721-4-5, IEC 61496-3 |
Shock Resistance | Class 5M1 (IEC 60721-3-5) |
Continuous Shock | 50 m/s², 11 ms |
Shock Resistance | Class 5M1 (IEC 60721-3-5) |
Shock Resistance | 100 m/s², 16 ms |
Other Data
Light Type | Pulsed laser diode |
Wavelength | 905 nm |
Detectable Remission Factor | 1.8% ... > 1,000 %, Reflectors |
Laser Class | 1 (21 CFR 1040.10 and 1040.11, IEC 60825-1) |
Classifications
ECLASS
ECLASS 5.0 | 27272705 |
ECLASS 5.1.4 | 27272705 |
ECLASS 6.0 | 27272705 |
ECLASS 6.2 | 27272705 |
ECLASS 7.0 | 27272705 |
ECLASS 8.0 | 27272705 |
ECLASS 8.1 | 27272705 |
ECLASS 9.0 | 27272705 |
ECLASS 10.0 | 27272705 |
ECLASS 11.0 | 27272705 |
ECLASS 12.0 | 27272705 |
ETIM
ETIM 5.0 | EC002550 |
ETIM 6.0 | EC002550 |
ETIM 7.0 | EC002550 |
ETIM 8.0 | EC002550 |
UNSPSC
UNSPSC 16.0901 | 39121528 |
Dimensional Drawing
The dimensional drawing shows the external dimensions of the SICK S300 safety laser scanner. It includes views from the front, side, and top, with key measurements indicated in millimeters and inches. For example, the overall height is 152 mm (5.98 in), the width is 102 mm (4.02 in), and the depth is 106 mm (4.17 in). Mounting hole details and the scanning plane origin are also depicted.
Wiring Example
This section illustrates a wiring example for safety field switching using the S300 Advanced with a UE10-30S connection module. It shows the connection of the +24V and 0V power supply, the system connector (S300 Advanced), and the UE10-30S module's inputs and outputs. The diagram details how to connect the safety outputs (OSSDs) and controller inputs for functions like restart interlock and safety field switching via controller input IN A. Notes clarify the integration of output circuits into the controller for safety and the requirements for two-channel integration (x, y-paths) for categories 4 and 3.
Recommended Accessories
Mounting Brackets and Plates
Short Description | Type | Article Number |
---|---|---|
1 piece, Mounting bracket for mounting on the rear, wall, or machine | Mounting Set 1a | 2034324 |
1 piece, Mounting bracket for mounting on the rear, wall, or machine with protection for the optical cover | Mounting Set 1b | 2034325 |
1 piece, Mounting bracket, adjustment on transverse axis possible, only in combination with Mounting Set 1a (2034324) or 1b (2034325) | Mounting Set 2 | 2039302 |
1 piece, Mounting plate, adjustment on longitudinal axis possible, only in combination with Mounting Set 2 (2039302) | Mounting Set 3 | 2039303 |
Miscellaneous
Short Description | Type | Article Number |
---|---|---|
Connection Type Head A: Connector, M8, 4-pin, straight Connection Type Head B: Connector, USB-A, straight Cable: 2 m, 4-wire, PVC Description: Not isolated, Configuration cable with integrated converter RS-232 to USB for connecting a sensor configuration interface (M8, 4-pin) to the USB interface of a PC | DSL-8U04G02M025KM1 | 6034574 |
Connection Type Head A: Connector, M8, 4-pin, straight Connection Type Head B: Connector, USB-A, straight Cable: 10 m, 4-wire, PVC Description: Not isolated, Configuration cable with integrated converter RS-232 to USB for connecting a sensor configuration interface (M8, 4-pin) to the USB interface of a PC | DSL-8U04G10M025KM1 | 6034575 |
Connection Type Head A: System connector Scope of Delivery: With 1 x cable coupling M16, 1 x blind plug M16, 2 x blind plug M12 Description: Without cable, not for use with incremental encoders, integrated configuration memory, for S300 Standard, Advanced, Expert, and Professional | SX0B-A0000G | 2032807 |
Connection Type Head A: Open cable end Connection Type Head B: Open cable end Scope of Delivery: Per running meter Cable: 15-wire, AWG20, PVC Description: Not isolated Note: In 100m roll | Connection Cable | 6030795 |
Connection Type Head A: System connector Scope of Delivery: With 1 x cable coupling M16, 1 x blind plug M16, 2 x blind plug M12 Cable: 5 m, 15-wire, PVC Description: Pre-assembled, not for use with incremental encoders, integrated configuration memory, not isolated, for S300 Advanced, Expert, and Professional Connection Technology: Open cable end | SX0B-B1505G | 2034264 |
Connection Type Head A: System connector Scope of Delivery: With 1 x cable coupling M16, 1 x blind plug M16, 2 x blind plug M12 Cable: 10 m, 15-wire, PVC Description: Pre-assembled, not for use with incremental encoders, integrated configuration memory, not isolated, for S300 Advanced, Expert, and Professional Connection Technology: Open cable end | SX0B-B1510G | 2034265 |
Connection Type Head A: Open cable end Connection Type Head B: Open cable end Scope of Delivery: Per running meter Cable: 2-wire, twisted per pair, 120 ohm, PVC Description: Isolated Note: Suitable for EFI communication | Connection Cable EFI | 6029448 |
SICK at a Glance
SICK is one of the leading manufacturers of intelligent sensors and sensor solutions for industrial applications. Its unique offering of products and services provides a perfect foundation for safe and efficient process control, protection of people from accidents, and prevention of environmental pollution. With extensive experience across diverse domains, SICK understands industry-specific processes and requirements, delivering precise solutions with intelligent sensors. Test centers in Europe, Asia, and North America optimize system solutions for customers, making SICK a reliable supplier and R&D partner. Comprehensive services, including SICK LifeTime Services, support customers throughout the entire machine lifecycle, ensuring safety and productivity. This commitment defines SICK's "Sensor Intelligence".
Worldwide Near You: Contact persons and other locations available at www.sick.com.