Generac Protector Series Standby Generators
Brand: Generac
Product Type: Standby Generators
Overview
The Generac Protector Series offers liquid-cooled gaseous standby generators designed for reliable power backup. These generators feature advanced technology for optimal performance and durability.
Key Inclusions
- Two-Line LCD Multilingual Digital Evolution™ Controller (English/Spanish/French/Portuguese) with external viewing window for easy indication of generator status and breaker position.
- Capability to be installed with 18" (457mm) of a building*
- True Power™ Electrical Technology
- Isochronous Electronic Governor
- Sound Attenuated Enclosure
- Closed Coolant Recovery System
- Smart Battery Charger
- UV/Ozone Resistant Hoses
- ±1% Voltage Regulation
- Natural Gas or LP Operation
- 5 Year Limited Warranty
- UL 2200 Listed
Note: 25-45 kW units are field convertible between natural gas or liquid propane. 60 kW units are built per fuel requirement and are not convertible.
*Only if located away from doors, windows, and fresh air intakes, and unless otherwise directed by local codes. Applicable for 25kW and 30kW units only.
Standby Power Ratings:
- Model RG025 (Aluminum - Bisque) - 25 kW 60 Hz
- Model RG030 (Aluminum - Bisque) - 30 kW 60 Hz
- Model RG036 (Aluminum - Bisque) - 36 kW 60 Hz
- Model RG045 (Aluminum - Bisque) - 45 kW 60 Hz
- Model RG060 (Aluminum - Bisque) - 60 kW 60 Hz
Compliance: Assembled in the USA using domestic and foreign parts. Meets EPA Emission Regulations. 25, 30 & 45 kW models are CA/MA emissions compliant. 36 & 60 kW models are not for sale in CA / MA.
Features
Innovative Design & Prototype Testing: Generac emphasizes "IMPROVING POWER BY DESIGN" through rigorous component, reliability, environmental, destruction, and life testing, adhering to CSA, NEMA, EGSA, and other standards.
Test Criteria
- ✔️ Prototype Tested
- ✔️ System Torsional Tested
- ✔️ NEMA MG1-22 Evaluation
- ✔️ Motor Starting Ability
Solid-State, Frequency Compensated Voltage Regulation: This system provides optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque-matching surge loads to the engine. Digital voltage regulation is maintained at ±1%.
Single Source Service Response: Generac's extensive dealer network offers comprehensive parts and service expertise for the entire unit.
Generac Transfer Switches: The product line includes integrated transfer systems and controls for total system compatibility, ensuring long life and reliability.
Specifications
Generator Specifications
Type | Synchronous |
Rotor Insulation Class | H |
Stator Insulation Class | H |
Telephone Interference Factor (TIF) | <50 |
Alternator Output Leads 1-Phase | 4 wire |
Alternator Output Leads 3-Phase | 6 wire |
Bearings | Sealed Ball |
Coupling | Flexible Disc |
Excitation System | Direct |
Voltage Regulation
Type | Electronic |
Sensing | Single Phase |
Regulation | ±1% |
Governor Specifications
Type | Electronic |
Frequency Regulation | Isochronous |
Steady State Regulation | ±0.25% |
Electrical System
Battery Charge Alternator | 12 Volt 15 Amp - 25 & 30 kW 12 Volt 30 Amp - 36, 45 & 60 kW |
Static Battery Charger | 2 Amp |
Recommended Battery (battery not included) | Group 26, 525CCA |
System Voltage | 12 Volts |
Generator Features
- Revolving field heavy duty generator, directly connected to the engine.
- Operating temperature rise: 120 °C above a 40 °C ambient.
- Class H insulation is NEMA rated.
- All models fully prototyped tested.
Enclosure Features
- Aluminum weather protective enclosure: Ensures protection against environmental factors. Features electrostatically applied textured epoxy paint for durability.
- Enclosed critical grade muffler: Provides quiet operation and prevents injuries.
- Small, compact, attractive: Designed for easy, eye-appealing installation.
- SAE: Sound attenuated enclosure ensures quiet operation.
Engine Specifications: 25 & 30 kW
Make | Generac |
Model | In-line |
Cylinders | 4 |
Displacement (Liters) | 1.5 |
Bore (in/mm) | 3.05/77.4 |
Stroke (in/mm) | 3.13/79.5 |
Compression Ratio | 11:1 |
Intake Air System | Naturally Aspirated |
Lifter Type | Hydraulic |
Engine Specifications: 36, 45 & 60 kW
Make | Generac |
Model | In-line |
Cylinders | 4 |
Displacement (Liters) | 2.4 |
Bore (in/mm) | 3.41/86.5 |
Stroke (in/mm) | 3.94/100 |
Compression Ratio | 9.5:1 |
Intake Air System | Naturally Aspirated (36 & 45 kW) or Turbocharged/Aftercooled (60 kW) |
Lifter Type | Hydraulic |
Engine Lubrication System
Oil Pump Type | Gear |
Oil Filter Type | Full flow spin-on cartridge |
Crankcase Capacity (qt/l) | 4/3.8 - 25, 30, 36 & 45 kW 5.25/4.96 - 60 kW |
Engine Cooling System
Type | Closed |
Water Pump | Belt driven |
Fan Speed (rpm) | 2484 - 25 & 30 kW 1865 - 36 & 45 kW 2100 - 60 kW |
Fan Diameter (in/mm) | 17.7/449.6 (25 & 30 kW) or 22/558.8 (36, 45 & 60 kW) |
Fan Mode | Pusher (25 & 30 kW) or Puller (36, 45 & 60 kW) |
Fuel System
Fuel Type | Natural gas, propane vapor |
Carburetor | Down Draft |
Secondary Fuel Regulator | Standard |
Fuel Shut Off Solenoid | Standard |
Operating Fuel Pressure | 5-14" water column/9-26 mm HG |
LP Fuel Pressure | 11-14" Water Column |
NG Fuel Pressure | 5-14" Water Column |
(All ratings in accordance with BS5514, ISO3046, ISO8528, SAE J1349 and DIN6271)
Performance Data
Generator Output Voltage/kW - 60 Hz
Model | kW LPG | Amp LPG | kW Nat. Gas | Amp Nat. Gas | CB Size (Both) |
---|---|---|---|---|---|
RG025 | 25 | 104 | 25 | 104 | 125 |
RG025 | 25 | 87 | 25 | 87 | 100 |
RG025 | 25 | 75 | 25 | 75 | 90 |
RG030 | 30 | 125 | 30 | 125 | 150 |
RG030 | 30 | 104 | 30 | 104 | 125 |
RG030 | 30 | 90 | 30 | 90 | 100 |
RG036 | 36 | 150 | 36 | 150 | 175 |
RG036 | 36 | 125 | 36 | 125 | 150 |
RG036 | 36 | 108 | 36 | 108 | 125 |
RG036 | 36 | 54 | 36 | 54 | 60 |
RG045 | 45 | 188 | 45 | 188 | 200 |
RG045 | 45 | 156 | 45 | 156 | 175 |
RG045 | 45 | 135 | 45 | 135 | 150 |
RG045 | 45 | 68 | 45 | 68 | 80 |
RG060 | 60 | 250 | 60 | 250 | 300 |
RG060 | 60 | 208 | 60 | 208 | 250 |
RG060 | 60 | 180 | 60 | 180 | 200 |
RG060 | 60 | 90 | 60 | 90 | 100 |
Surge Capacity in Amps (Voltage Dip @ < .4 pf)
Model | Voltage | 15% | 30% |
---|---|---|---|
RG025 | 120/240 V, 1Ø | 65 | 170 |
RG025 | 120/208 V, 3Ø | 80 | 130 |
RG025 | 120/240 V, 3Ø | 69 | 112 |
RG030 | 120/240 V, 1Ø | 75 | 180 |
RG030 | 120/208 V, 3Ø | 96 | 155 |
RG030 | 120/240 V, 3Ø | 83 | 134 |
RG036 | 120/240 V, 1Ø | 105 | 240 |
RG036 | 120/208 V, 3Ø | 44 | 130 |
RG036 | 120/240 V, 3Ø | 38 | 115 |
RG036 | 277/480 V, 3Ø | 20 | 60 |
RG045 | 120/240 V, 1Ø | 105 | 240 |
RG045 | 120/208 V, 3Ø | 44 | 130 |
RG045 | 120/240 V, 3Ø | 38 | 115 |
RG045 | 277/480 V, 3Ø | 20 | 60 |
RG060 | 120/240 V, 1Ø | 140 | 320 |
RG060 | 120/208 V, 3Ø | 70 | 210 |
RG060 | 120/240 V, 3Ø | 61 | 182 |
RG060 | 277/480 V, 3Ø | 30 | 91 |
Note: Fuel pipe must be sized for full load.
For Btu content, multiply ft³/hr x 2520 (LP) or ft³/hr x 1000 (NG).
For megajoule content, multiply m³/hr x 93.15 (LP) or m³/hr x 37.26 (NG).
Refer to "Emissions Data Sheets" for maximum fuel flow for EPA and SCAQMD permitting purposes.
Engine Fuel Consumption
Model | Natural Gas | Propane | ||||
---|---|---|---|---|---|---|
(ft³/hr) | (m³/hr) | (gal/hr) | (l/hr) | (ft³/hr) | ||
RG025 | Exercise cycle | 60 | 1.7 | 0.7 | 2.5 | 24 |
RG025 | 25% of rated load | 220 | 6.3 | 2.9 | 9.1 | 88 |
RG025 | 50% of rated load | 297 | 8.4 | 3.3 | 12.3 | 119 |
RG025 | 75% of rated load | 362 | 10.3 | 4 | 15 | 145 |
RG025 | 100% of rated load | 430 | 12.2 | 4.7 | 17.8 | 172 |
RG030 | Exercise cycle | 60 | 1.7 | 0.7 | 2.5 | 24 |
RG030 | 25% of rated load | 240 | 6.8 | 2.6 | 10 | 96 |
RG030 | 50% of rated load | 320 | 9.1 | 3.5 | 13.3 | 128 |
RG030 | 75% of rated load | 400 | 11.4 | 4.4 | 16.6 | 160 |
RG030 | 100% of rated load | 492 | 14 | 5.4 | 20.4 | 197 |
RG036 | Exercise cycle | 65 | 1.8 | 0.7 | 2.6 | 25 |
RG036 | 25% of rated load | 210 | 6 | 2.3 | 8.6 | 83 |
RG036 | 50% of rated load | 380 | 10.8 | 4.2 | 15.7 | 151 |
RG036 | 75% of rated load | 545 | 15.5 | 5.9 | 22.4 | 216 |
RG036 | 100% of rated load | 730 | 20.7 | 8 | 30.1 | 290 |
RG045 | Exercise cycle | 65 | 1.8 | 0.7 | 2.6 | 25 |
RG045 | 25% of rated load | 210 | 6 | 2.3 | 8.6 | 83 |
RG045 | 50% of rated load | 380 | 10.8 | 4.2 | 15.7 | 151 |
RG045 | 75% of rated load | 545 | 15.5 | 5.9 | 22.4 | 216 |
RG045 | 100% of rated load | 730 | 20.7 | 8 | 30.1 | 290 |
RG060 | Exercise cycle | 123 | 3.5 | 1.34 | 5.1 | 49.3 |
RG060 | 25% of rated load | 267 | 7.6 | 2.7 | 10.5 | 101 |
RG060 | 50% of rated load | 483 | 13.7 | 5 | 19 | 183 |
RG060 | 75% of rated load | 672 | 19.1 | 7 | 26.5 | 255 |
RG060 | 100% of rated load | 862 | 24.5 | 9 | 33.9 | 327 |
STANDBY RATING: Standby ratings apply to installations served by a reliable utility source. The standby rating is applicable to varying loads for the duration of a power outage. There is no overload capability for this rating. Ratings are in accordance with ISO-3046-1. Design and specifications are subject to change without notice.
Ambient Conditions & Controller Features
Engine Cooling
Air flow (inlet air including alternator and combustion air in cfm/cmm) | 25 kW: 2490/70.5 | 30 kW: 2490/70.5 | 36 kW: 2725/77.2 | 45 kW: 2725/77.2 | 60 kW: 3280/92.9 |
System coolant capacity (gal/liters) | 2/7.6 | 2/7.6 | 2.5/9.5 | 2.5/9.5 | 2.5/9.5 |
Heat rejection to coolant (BTU per hr/MJ per hr) | 112,000/118.2 | 135,000/142.4 | 193,000/203.6 | 193,000/203.6 | 270,000/284.9 |
Maximum operation air temperature on radiator (°C/°F) | 60/140 | ||||
Maximum ambient temperature (°C/°F) | 50/122 |
Combustion Requirements
Flow at rated power (cfm/cmm) | 25 kW: 62/1.8 | 30 kW: 72/2 | 36 kW: 144/4.1 | 45 kW: 144/4.1 | 60 kW: 180/5.1 |
Sound Emissions
Sound output in dB(A) at 23 ft (7 m) with generator in exercise mode* | 25 kW: 59 | 30 kW: 59 | 36 kW: 61 | 45 kW: 61 | 60 kW: 65 |
Sound output in dB(A) at 23 ft (7 m) with generator operating at normal load* | 25 kW: 72 | 30 kW: 73 | 36 kW: 70 | 45 kW: 73 | 60 kW: 72 |
*Sound levels are taken from the front of the generator. Sound levels taken from other sides of the generator may be higher depending on installation parameters.
Exhaust
Exhaust flow at rated output (cfm/cmm) | 25 kW: 203/5.7 | 30 kW: 237/6.7 | 36 kW: 300/8.5 | 45 kW: 420/11.9 | 60 kW: 494/14 |
Exhaust temperature at muffler outlet (°C/°F) | 25 kW: 593/1100 | 30 kW: 610/1130 | 36 kW: 579/1075 | 45 kW: 593/1100 | 60 kW: 566/1050 |
Engine Parameters
Rated Synchronous rpm | 3600 |
Power Adjustment for Ambient Conditions
Temperature Deration: 3% for every 10 °C above 25 °C or 1.65% for every 10 °F above 77 °F
Altitude Deration (25, 30, 36 & 45 kW): 1% for every 100 m above 183 m or 3% for every 1000 ft above 600 ft
Altitude Deration (60 kW): 1% for every 100 m above 915 m or 3% for every 1000 ft above 3000 ft
Controller Features
- Two-Line Plain Text LCD Display: Simple user interface for ease of operation.
- Mode Switch: Auto (Automatic Start on Utility failure. 7 day exerciser), Off (Stops unit. Power is removed. Control and charger still operate.), Manual (Start with starter control, unit stays on. If utility fails, transfer to load takes place.)
- Programmable start delay between 10-30 seconds: 10 sec Standard
- Engine Start Sequence: Cyclic cranking: 16 sec on, 7 rest (90 sec maximum duration)
- Engine Warm-up: 5 sec
- Engine Cool-Down: 1 min
- Starter Lock-out: Starter cannot re-engage until 5 sec after engine has stopped.
- Smart Battery Charger: Standard
- Automatic Voltage Regulation with Over and Under Voltage Protection: Standard
- Automatic Low Oil Pressure Shutdown: Standard
- Overspeed Shutdown: Standard, 72 Hz
- High Temperature Shutdown: Standard
- Overcrank Protection: Standard
- Safety Fused: Standard
- Failure to Transfer Protection: Standard
- Low Battery Protection: Standard
- 50 Event Run Log: Standard
- Future Set Capable Exerciser: Standard
- Incorrect Wiring Protection: Standard
- Internal Fault Protection: Standard
- Common External Fault Capability: Standard
- Governor Failure Protection: Standard
Available Accessories
- Model #: G006463-4
Product: Mobile Link™™
Description: Generac's Mobile Link allows you to check the status of your generator from anywhere that you have access to an Internet connection from a PC or with any smart device. You will even be notified when a change in the generator's status occurs via e-mail or text message. Note: Harness Adapter Kit required. Available in the U.S. only. - Model #: G006478-0
Product: Harness Adapter Kit
Description: The Harness Adapter Kit is required to make liquid-cooled units compatible with Mobile Link™™. - Model #: G006175-0 - 25 & 30 kW, G005630-1 - 36, 45 & 60 kW
Product: Cold Weather Kit
Description: If the temperature regularly falls below 32 °F (0 °C), install a cold weather kit to maintain optimal battery temperature. Kit consists of battery warmer with thermostat built into the wrap. - Model #: G006174-0 - 25 & 30 kW, G005616-0 - 36, 45 & 60 kW
Product: Extreme Cold Weather Kit
Description: Recommended where the temperature regularly falls below 32 °F (0 °C) for extended periods of time. For liquid cooled units only. - Model #: G005651-0
Product: Base Plug Kit
Description: Add base plugs to the base of the generator to keep out debris. - Model #: G005703-0 - Bisque
Product: Paint Kit
Description: If the generator enclosure is scratched or damaged, it is important to touch-up the paint to protect from future corrosion. The paint kit includes the necessary paint to properly maintain or touch-up a generator enclosure. - Model #: G006176-0 - 25 & 30 kW, G006172-0 - 36 & 45 kW, G006171-0 - 60 kW
Product: Scheduled Maintenance Kit
Description: The Liquid-Cooled Scheduled Maintenance Kits offer all the hardware necessary to perform complete maintenance on Generac liquid-cooled generators. - Model #: G006664-0
Product: Local Wireless Monitor
Description: Completely wireless and battery powered, Generac's wireless remote monitor provides you with instant status information without ever going outside. - Model #: G006665-0
Product: Wireless Remote Extension Harness
Description: Recommended for use with the Wireless Remote on units up to 60 kW, required for use on units 70 kW or greater. - Model #: G006873-0
Product: Smart Management Module (50 Amps)
Description: Smart Management Modules are used in conjunction with the Automatic Transfer Switch to increase its power management capabilities. It provides additional power management flexibility not found in any other power management system. - Model #: G006510-0
Product: E-Stop
Description: E-stop allows for immediate fuel shutoff and generator shutdown in the event of an emergency. - Model #: G007005-0
Product: Wi-Fi LP Fuel Level Monitor
Description: The Wi-Fi enabled LP fuel level monitor provides constant monitoring of the connected LP fuel tank. Monitoring the LP tank's fuel level is an important step in making sure your generator is ready to run during an unexpected power failure. Status alerts are available through a free application to notify when your LP tank is in need of a refill.
Installation Layout: 25 & 30 kW (Page 1 of 2)
This section describes the physical layout and dimensions for the 25 & 30 kW models.
Top View
Shows air intake (both sides), radiator/exhaust discharge air (both sides). Key dimensions: 665.5 [26.2"] (Center of Gravity, see Note 5).
Service Items (Accessible via doors)
- Oil Fill Cap: EITHER DOOR
- Oil Dip Stick: RIGHT DOOR
- Oil Filter: RIGHT DOOR
- Oil Drain Hose: RIGHT DOOR
- Radiator Drain Hose: RIGHT DOOR
- Air Cleaner Element: RIGHT DOOR
- Spark Plugs: RIGHT DOOR
- Muffler: SEE NOTE 12
- Fan Belt: EITHER DOOR
- Battery: RIGHT DOOR
Note: Reference Owner's Manual for periodic replacement part listings.
Diagram Elements: Circuit Breaker, Neutral and Customer Connection Opening, Vise Action Latch (one per door, one lift-off door per side of generator), Exhaust Muffler enclosed within generator enclosure, Lifting Provision (4 places).
Overall Dimensions: Length: 1580 [62.2"]; Height: 980 [38.6"]; Width: 776 [30.6"]; Door Type: 631 [24.8"]; Typical: 48 [1.9"] / 45 [1.8"]; Right Side View: 780 [30.7"]; Typical: 1490 [58.7"]
Fuel Line Connection: 3/4" NPT Female Coupling.
Weight Data
Engine/KW | Enclosure Material | Weight Genset Only (KG [LBS]) | Weight Shipping Skid (KG [LBS]) | Shipping Weight (KG [LBS]) |
---|---|---|---|---|
1.5L/25KW | ST | 392 [865] | 30 [66] | 422 [931] |
1.5L/30KW | ST | 406 [895] | 30 [66] | 436 [961] |
1.5L/25KW | AL | 352 [777] | 30 [66] | 382 [843] |
1.5L/30KW | AL | 366 [807] | 30 [66] | 396 [873] |
Notes:
- Minimum recommended concrete pad size: 1092 (43") WIDE X 1887 (74.3") LONG. Reference Installation Guide supplied with unit for concrete pad guidelines.
- Allow sufficient room on all sides of the generator for maintenance and servicing. Unit must be installed in accordance with current applicable NFPA 37 and NFPA 70 standards as well as any other federal, state, and local codes.
- Control Panel / Circuit Breaker Information: See Specification Sheet or Owners Manual. Accessible through Customer Access Assembly Door on rear of generator.
- Remove the rear enclosure cover panel to access the stub-up areas for: High voltage connection (AC load lead conduit connection, neutral connection, battery charger 120 volt AC (0.5 AMP MAX) connection) and Low voltage connection (transfer switch control wires).
- Center of gravity and weight may change due to unit options.
- Bottom of generator set must be enclosed to prevent pest intrusion and recirculation of discharge air and/or improper cooling air flow.
- Exhaust system maximum back pressure: 24 inches H2O.
- Reference Owners Manual for lifting warnings.
- Mounting bolts or studs to mounting surface shall be 5/8-11 Grade 5 (use standard SAE torque specs).
- Must allow free flow of intake air, discharge air and exhaust. See spec sheet for minimum air flow and maximum restriction requirements.
- Generator must be installed such that fresh cooling air is available and that discharge air from radiator is not recirculated.
- Exhaust muffler enclosed within generator enclosure; remove enclosure to access exhaust muffler.
Installation Layout: 25 & 30 kW (Page 2 of 2)
This section provides detailed dimensional drawings for the 25 & 30 kW models.
Top View
Shows mounting slots (13.5 X 29.5, 4X) and mounting slot centers (1380 [54.3"] TYP). Features a stub-up area for high and low voltage connections, circuit breaker, neutral, and customer connection opening.
Left Side View
Overall dimensions: Length 1580 [62.2"].
Rear View
Overall dimensions: Width 776 [30.6"]. Features a removable stub-up cover. Mounting slot centers: 723 [28.5"] TYP.
Note: Stub-up area for high and low voltage connections, circuit breaker, neutral, and customer connection opening.
Installation Layout: 36 & 45 kW (Page 1 of 2)
This section describes the physical layout and dimensions for the 36 & 45 kW models.
Top View
Shows air intake (both sides), radiator/exhaust discharge air (both sides). Key dimensions: 749.3 [29.5"] (Center of Gravity, see Note 5). Features a removable cover for access to radiator fill cap and lube oil maintainer supply tank.
Service Items (Accessible via doors/sides)
- Oil Fill Cap: EITHER SIDE
- Oil Dip Stick: RIGHT SIDE
- Oil Filter: RIGHT SIDE
- Oil Drain Hose: RIGHT SIDE
- Radiator Drain Hose: LEFT SIDE
- Coolant Recovery Bottle: LEFT SIDE
- Radiator Fill Cap: ROOF TOP
- Air Cleaner Element: LEFT SIDE
- Spark Plugs: LEFT SIDE
- Muffler: SEE NOTE 11
- Drive Belt: EITHER SIDE
- Fan Belt: SEE NOTE 11
- Battery: LEFT SIDE
- Lube Oil Maintainer Supply Tank Fill Cap: ROOF TOP
Note: Reference Owner's Manual for periodic replacement part listings.
Diagram Elements: Circuit Breaker (see Note 3), Exhaust Muffler enclosed within generator enclosure, Vise Action Latch (one per door, one lift-off door per side of generator).
Overall Dimensions: Height: 1170 [46.1"]; Width: 888 [35.0"]; Typical Door: 758 [29.8"]; Typical: 50 [2.0"] / 46.5 [1.83"]; Left Side View: 1000 [39.4"]; Overall Length: 1950 [76.8"] TYP, 1857 [73.1"] TYP.
Fuel Line Connection: 3/4" NPT Female Coupling.
Weight Data
Engine/KW | Enclosure Material | Weight Genset Only (KG [LBS]) | Weight Shipping Skid (KG [LBS]) | Shipping Weight (KG [LBS]) |
---|---|---|---|---|
2.4L 36KW | ST | 569 [1255] | 44 [98] | 613 [1353] |
2.4L 36KW | AL | 545 [1202] | 44 [98] | 590 [1300] |
2.4L 45KW | ST | 596 [1313] | 44 [98] | 640 [1411] |
2.4L 45KW | AL | 572 [1260] | 44 [98] | 616 [1358] |
Notes:
- Minimum recommended concrete pad size: 1194MM (47") WIDE X 2256MM (88.8") LONG. Reference Installation Guide supplied with unit for concrete pad guidelines.
- Allow sufficient room on all sides of the generator for maintenance and servicing. Unit must be installed in accordance with current applicable NFPA 37 and NFPA 70 standards as well as any other federal, state, and local codes.
- Control Panel / Circuit Breaker Information: See Specification Sheet or Owners Manual. Accessible through Customer Access Assembly Door on rear of generator.
- Remove the rear enclosure cover panel to access the stub-up areas for: High voltage connection (AC load lead conduit connection, neutral connection, battery charger 120 volt AC (0.5 AMP MAX) connection) and Low voltage connection (transfer switch control wires).
- Center of gravity and weight may change due to unit options.
- Bottom of generator set must be enclosed to prevent pest intrusion and recirculation of discharge air and/or improper cooling air flow.
- Reference Owners Manual for lifting warnings.
- Mounting bolts or studs to mounting surface shall be 5/8-11 Grade 5 (use standard SAE torque specs).
- Must allow free flow of intake air, discharge air and exhaust. See spec sheet for minimum air flow and maximum restriction requirements.
- Generator must be installed such that fresh cooling air is available and that discharge air from radiator is not recirculated.
- Exhaust muffler and fan belt enclosed within generator enclosure; remove front panel to access.
Installation Layout: 36 & 45 kW (Page 2 of 2)
This section provides detailed dimensional drawings for the 36 & 45 kW models.
Top View
Shows mounting slots (13.5 X 29.5, 4X) and mounting slot centers (1733 [68.2"] TYP). Features a stub-up area for high and low voltage connections, circuit breaker, neutral, and customer connection opening.
Left Side View
Overall dimensions: Length 1750 [68.9"] TYP, 1950 [76.8"].
Rear View
Overall dimensions: Width 888 [35.0"]. Features a removable stub-up cover. Mounting slot centers: 838 [33.0"] TYP.
Note: Stub-up area for high and low voltage connections, circuit breaker, neutral, and customer connection opening.
Installation Layout: 60 kW (Page 1 of 2)
This section describes the physical layout and dimensions for the 60 kW model.
Top View
Shows air intake (both sides), radiator/exhaust discharge air (both sides). Key dimensions: 683.3 [26.9"] (Center of Gravity). Features a removable cover for access to radiator fill cap and lube oil maintainer supply tank.
Service Items (Accessible via doors/sides)
- Oil Fill Cap: EITHER SIDE
- Oil Dip Stick: RIGHT SIDE
- Oil Filter: LEFT SIDE
- Oil Drain Hose: RIGHT SIDE
- Radiator Drain Hose: LEFT SIDE
- Coolant Recovery Bottle: LEFT SIDE
- Radiator Fill Cap: ROOF TOP
- Air Cleaner Element: LEFT SIDE
- Spark Plugs: LEFT SIDE
- Muffler: SEE NOTE 11
- Drive Belt: EITHER SIDE
- Fan Belt: SEE NOTE 11
- Battery: LEFT SIDE
- Lube Oil Maintainer Supply Tank Fill Cap: ROOF TOP
Note: Reference Owner's Manual for periodic replacement part listings.
Diagram Elements: Circuit Breaker (see Note 3), Exhaust Muffler enclosed within generator enclosure, Vise Action Latch (one per door, one lift-off door per side of generator).
Overall Dimensions: Height: 1170 [46.1"]; Width: 888 [35.0"]; Typical Door: 758 [29.8"]; Typical: 50 [2.0"] / 58 [2.3"]; Left Side View: 1000 [39.4"]; Overall Length: 1950 [76.8"] TYP, 1857 [73.1"] TYP.
Fuel Line Connection: 3/4" NPT Female Coupling.
Weight Data
Engine/KW | Enclosure Material | Weight Genset Only (KG [LBS]) | Weight Shipping Skid (KG [LBS]) | Shipping Weight (KG [LBS]) |
---|---|---|---|---|
2.4L 60KW | ST | 582 [1283] | 44 [98] | 626 [1381] |
2.4L 60KW | AL | 558 [1230] | 44 [98] | 602 [1328] |
Notes:
- Minimum recommended concrete pad size: 1194MM (47") WIDE X 2256MM (88.8") LONG. Reference Installation Guide supplied with unit for concrete pad guidelines.
- Allow sufficient room on all sides of the generator for maintenance and servicing. Unit must be installed in accordance with current applicable NFPA 37 and NFPA 70 standards as well as any other federal, state, and local codes.
- Control Panel / Circuit Breaker Information: See Specification Sheet or Owners Manual. Accessible through Customer Access Assembly Door on rear of generator.
- Remove the rear enclosure cover panel to access the stub-up areas for: High voltage connection (AC load lead conduit connection, neutral connection, battery charger 120 volt AC (0.5 AMP MAX) connection) and Low voltage connection (transfer switch control wires).
- Center of gravity and weight may change due to unit options.
- Bottom of generator set must be enclosed to prevent pest intrusion and recirculation of discharge air and/or improper cooling air flow.
- Reference Owners Manual for lifting warnings.
- Mounting bolts or studs to mounting surface shall be 5/8-11 Grade 5 (use standard SAE torque specs).
- Must allow free flow of intake air, discharge air and exhaust. See spec sheet for minimum air flow and maximum restriction requirements.
- Generator must be installed such that fresh cooling air is available and that discharge air from radiator is not recirculated.
- Exhaust muffler and fan belt enclosed within generator enclosure; remove front panel to access.
Installation Layout: 60 kW (Page 2 of 2)
This section provides detailed dimensional drawings for the 60 kW model.
Top View
Shows mounting slots (13.5 X 29.5, 4X) and mounting slot centers (1733 [68.2"] TYP). Features a stub-up area for high and low voltage connections, circuit breaker, neutral, and customer connection opening.
Left Side View
Overall dimensions: Length 1750 [68.9"] TYP, 1950 [76.8"].
Rear View
Overall dimensions: Width 888 [35.0"]. Features a removable stub-up cover. Mounting slot centers: 838 [33.0"] TYP.
Note: Stub-up area for high and low voltage connections, circuit breaker, neutral, and customer connection opening.