Honeywell BW™ Icon+ Multi-Gas Monitor
A serviceable four-gas monitor with a choice of six sensors – the Honeywell BW™ Icon+ offers a symbol-based experience in a serviceable package. It allows users to maximize the lifespan of their four-gas monitors, optimize long-term operating costs, and select from multiple gas sensors for flexible applications.
Key Features
Icon Display for Quick Decisions
Like the fixed-life Honeywell BW™ Icon, the Honeywell BW™ Icon+ is named after its industry-first display featuring simple symbols for gas levels and device status. This eliminates the need for workers to interpret live gas readings and reduces the requirement for time-consuming training. During a gas alarm, the bell icon illuminates on the display, accompanied by an indicator next to the alarm sensor, enabling workers to quickly evacuate the area.
Intelligent Sensors for Predictive Maintenance
The Honeywell BW™ Icon+ is equipped with intelligent i-Series sensors that provide answers to critical questions, such as remaining lifespan of the H2S sensor based on age and gas exposure, or when the O2 sensor requires calibration. This allows for proactive measures to prevent unexpected downtime.
Reporting and Analysis from Your Smartphone
For detailed gas concentration data or other information not visible on the symbol-based display, users can download the Honeywell Safety Suite Device Configurator app. By pairing a smartphone with the detector via Bluetooth®, users can access and view data, all organized within a comprehensive report ready for sharing.
Features and Benefits
Reliable
Offers 2 months of runtime on a 4.5-hour charge, extending to up to 4 months if the detector is turned off at the end of each shift. This eliminates the need for daily charging and prevents unexpected downtime.
Compatible
The Honeywell BW™ Icon+ integrates seamlessly with the IntelliDoX instrument management system and the Honeywell Safety Suite. It also supports TouchConnect™ via Bluetooth® for effortless wireless configuration.
Accurate
Features a power-saving infrared UEG sensor that is immune to silicone poisoning, ensuring precise monitoring of flammable substances.
Easy to Manage
The green IntelliFlash™ light confirms device compliance, while a yellow light signals that maintenance is required.
Responsive
Series 1 sensors provide rapid response in seconds to dangerous gas levels, even under harsh temperature conditions.
Easy to Use
Designed to be small, lightweight, and portable, with simple one-button operation.
Gas Detection Capabilities
The detector is designed for common gas hazards, including: Combustible Gas (LEL), Oxygen (O2), Hydrogen Sulfide (H2S), Carbon Monoxide (CO), Sulfur Dioxide (SO2), and Chlorine (Cl2) (availability coming soon).
Technical Specifications
Specification | Details |
---|---|
Dimensions | 108.2 mm x 61.5 mm x 43.2 mm (4.29 in x 2.44 in x 1.7 in) with alligator clip; 108.2 mm x 61.5 mm x 37.8 mm (4.29 in x 2.44 in x 1.49 in) with Klick Fast Stud |
Weight | 185 g (6.5 oz) with alligator clip; 169 g (6 oz) with Klick Fast Stud |
Operating Temperature | -40 °C to 60 °C (-40 °F to 140 °F) |
Operating Humidity | 5% to 95% |
Ingress Protection | IP66, IP68 |
Alarms and Type | Visual, vibrating, audible (95 dB); Low, High, TWA, STEL, Negative Drift, Shelf Expiration, Multi-alarm |
Self-Test | Performs sensor and circuitry diagnostic at activation. The activated detector automatically performs an analog sensor diagnostic every 10 minutes, digital sensor diagnostic every second. |
Typical Battery Life | Two months (with NDIR CH4 Sensor) |
Connected Employee | Bluetooth® Low Energy (BLE) – ability to connect with the Safety Communicator App, the Device Configurator App, and the Safety Suite Device Configurator Software from Honeywell |
User Options | Modify alarm setpoints for High, Low, TWA, and STEL; Latch alarms; Set calibration and/or bump test reminders; Assign worker and location assignments; Always-on. User options available only via the Device Configurator and the Safety Suite Device Configurator. |
Certifications and Approvals | ATEX, IEC Ex, contains FCCID, contains IC |
Device Warranty | Three-year warranty on sensors and detector |
Sensor Specifications
Name of Gas | Measuring Range | Resolution | Operating Temperature |
---|---|---|---|
CO | 0 to 2000 ppm | 1 ppm | -40 °C to 60 °C (-40 °F to 140 °F) |
H2 S | 0 to 200 ppm | 1 ppm (can be set to 0.1 ppm) | -40 °C to 60 °C (-40 °F to 140 °F) |
SO 2 | 0 to 150 ppm | 0.1 ppm | -20 °C to 50 °C (-4 °F to 122 °F) intermittent; -40 °C to 55 °C (-40 °F to 131 °F) |
O 2 | 0 to 30% VOL | 0.1% VOL | -40 °C to 60 °C (-40 °F to 140 °F) |
NDIR-CH 4 | 0 to 100% LEL | 1% LEL | -40 °C to 60 °C (-40 °F to 140 °F) |
Important Note
The infrared UEG sensor used in the Honeywell BW™ Icon+ cannot detect hydrogen and acetylene. For applications where these flammable gases are used, consider a catalytic bead UEG sensor, such as those found in the Honeywell BW™ MicroClip series.