Resistex ENEIR Luminaire
Installation Instructions - Version V2.05.25
Safety and General Information
Safety Notes
⚠️ Never work when voltage is present on the luminaire.
The installation must be performed by a professional installer in compliance with the standards and regulations relating to electrical installations.
Risk of electrostatic discharges. [ESD]. Handle with precautions.
Please observe the notes and steps described in the mounting instructions.
Maintenance Instructions
Do not use chemicals or abrasive products to clean the fixture.
Keep these instructions for dismantling or future maintenance. You can consult additional information about RESISTEX luminaires on the website www.resistex-sa.com.
RESISTEX cannot be responsible for any misuse of the product.
Technical Specifications
- Warranty: 5 years
- Color Rendering Index (CRI): 80
- Impact Resistance (IK): 10
- Ingress Protection (IP): 66
- Certifications: CE, RoHS
Base (Borne) Installation
Step 1: Preparation and Assembly
This step involves preparing the base unit and pole components. It includes the assembly of the base with screws (X4) and mounting hardware (X1), illustrating how the base is prepared and attached to the pole.
Step 2: Ground Installation
The diagram shows the base being installed into the ground. It highlights correct installation with gravel for drainage (✅) and incorrect installation without it (❌). A recommended installation depth of 15cm is indicated.
Step 3: Electrical Connection and Activation
This step shows the connection point and the luminaire head being attached to the base. It includes an instruction to press and hold for 2 seconds ([Press and hold for 2 seconds]) for activation or setup.
Pole Top (Tête de mât) Installation
Step 1: Mounting the Luminaire Head
This step shows the luminaire head being mounted onto the pole top, including the use of mounting hardware (X1).
Step 2: Final Connection and Activation
This step illustrates the final assembly of the luminaire head onto the pole. It includes an instruction to press and hold for 2 seconds ([Press and hold for 2 seconds]) for activation or setup.