GoodWe ES Uniq Series Hybrid Inverter
Scalable and Reliable Hybrid Inverter for On-Grid and Off-Grid Operations
Product Overview
An illustration shows a modern house with a GoodWe ES Uniq inverter installed. The inverter is a sleek, white unit with a dark front panel displaying status lights and a small screen.
The ES Uniq series is a single-phase hybrid inverter specifically designed for residential applications, offering economical energy storage solutions with 8, 10, and 12kW capacities. This inverter is designed to support up to 200% oversizing capacity. It can manage up to 200% overload, ensuring reliable performance, especially during peak consumption. It facilitates parallel connection of up to 6 inverters for both grid-connected and off-grid operations, making it ideal for expanding energy needs. Furthermore, the ES Uniq inverter is compatible with microgrid operation, making it the ideal choice for residential self-consumption applications and microgrid scenarios, from self-consumption to energy self-sufficiency. ES Uniq is compatible with a wide range of batteries, including GoodWe batteries.
- ✔️ Flexible and adaptable applications
- ✔️ Maximum security and reliability
- ✔️ Higher energy generation
- ✔️ Intelligent control and monitoring
Key Features:
- ⚡ UPS equivalent switching time <4ms
- ? Smart Home system integration
- ⚙️ Parallel management and microgrid operation
Technical Specifications
Series ES Uniq
GoodWe | |||
---|---|---|---|
GW8000-ES-C10 | GW10K-ES-C10 | GW12K-ES-C10 | |
Battery Input | |||
Battery Type¹ | Lithium-ion / Lead-acid | Lithium-ion / Lead-acid | Lithium-ion / Lead-acid |
Nominal Battery Voltage (V) | 48 | 48 | 48 |
Battery Voltage Range (V) | 40~60 | 40~60 | 40~60 |
Startup Voltage (V) | 44.2 | 44.2 | 44.2 |
No. of Battery Inputs | 1 | 1 | 1 |
Max. Continuous Charge Current (A) | 160 | 200 | 240 |
Max. Continuous Discharge Current (A) | 160 | 200 | 240 |
Max. Charge Power (kW) | 8.0*2 | 10.0*2 | 12.0*2 |
Max. Discharge Power (kW) | 8.8*2 | 11.0*2 | 13.2*2 |
PV Input | |||
Max. Input Power (kW) | 16 | 20 | 24 |
Max. Input Voltage (V)³ | 600 | 600 | 600 |
MPPT Operating Voltage Range (V)⁴ | 60~550 | 60~550 | 60~550 |
Startup Voltage (V) | 58 | 58 | 58 |
Nominal Input Voltage (V) | 360 | 360 | 360 |
Max. Input Current per MPPT (A) | 32/16*5 | 32/32*5 | 32/32*5 |
Max. Short Circuit Current per MPPT (A) | 48/24 | 48/48 | 48/48 |
Number of Trackers (MPPT) | 2 | 2 | 2 |
Number of PV Strings per MPPT | 2/1 | 2/2 | 2/2 |
AC Output (Grid) | |||
Rated Output Power (kW) | 8.0 | 10.0 | 12.0 |
Rated Apparent Power to Grid (kVA) | 8.0 | 10.0 | 12.0 |
Max. Active Power (kW) | 8.8 | 11.0 | 13.2 |
Max. Apparent Power to Grid (kVA) | 8.8 | 11.0 | 13.2 |
Max. Apparent Power from Grid (kVA) | 16.5 | 16.5 | 16.5 |
Nominal Output Voltage (V) | 220/230/240 | ||
Output Voltage Range (V) | 170~280 | ||
Nominal Grid Frequency (Hz) | 50/60 | ||
Grid Frequency Range (Hz) | 45~55/55~65 | ||
Max. Output Current to Grid (A) | 40 | 50 | 60 |
Max. Current from Grid (A) | 75 | 75 | 75 |
Power Factor | ~1 (Adjustable, from 0.8 capacitive to 0.8 inductive) | ||
Max. Total Harmonic Distortion | <3% | ||
AC Output (Backup) | |||
Rated Backup Apparent Power (kVA) | 8.0 | 10.0 | 12.0 |
Max. Off-Grid Output Apparent Power (kVA) | 8.8 (16, 10s) | 11.0 (20, 10s) | 13.2 (24, 10s) |
Max. Off-Grid Output Current (A) | 40 | 50 | 60 |
Max. Grid-Connected Output Current (A) | 40 | 50 | 60 |
Nominal Output Voltage (V) | 220/230/240 | ||
Nominal Output Frequency (Hz) | 50/60 | ||
Output THDv (at linear load) | <3% | ||
AC (Generator) Data | |||
Rated AC Generator Apparent Power (kVA) | 8.0 | 10.0 | 12.0 |
Max. AC Generator Apparent Power (kVA) | 8.8 | 11.0 | 13.2 |
Nominal Input Voltage (V) | 220/230/240 | ||
Input Voltage Range (V) | 170~280 | ||
Nominal AC Generator Frequency (Hz) | 50.0 | ||
AC Generator Frequency Range (Hz) | 45~55/55~65 | ||
Maximum AC Generator Current (A) | 36.4 @ 220V 34.8 @ 230V 33.3 @ 240V | 45.5 @ 220V 43.5 @ 230V 41.7 @ 240V | 54.5 @ 220V 52.2 @ 230V 50.0 @ 240V |
Nominal AC Generator Current (A) | 36.4 @ 220V 34.8 @ 230V 33.3 @ 240V | 45.5 @ 220V 43.5 @ 230V 41.7 @ 240V | 54.5 @ 220V 52.2 @ 230V 50.0 @ 240V |
Nominal Input Current (A) | 50.0 | 54.5 | 54.5 |
Efficiency | |||
Max. Efficiency | 97.6% | 97.6% | 97.6% |
European Efficiency | 96.2% | 96.2% | 96.2% |
Max. Battery to Grid Efficiency | 95.5% | 95.5% | 95.5% |
MPPT Efficiency | 99.9% | 99.9% | 99.9% |
Protections | |||
PV String Current Monitoring | Integrated | ||
PV Insulation Resistance Detection | Integrated | ||
Residual Current Monitoring | Integrated | ||
DC Reverse Polarity Protection | Integrated | ||
Anti-islanding Protection | Integrated | ||
AC Overcurrent Protection | Integrated | ||
AC Short Circuit Protection | Integrated | ||
AC Overvoltage Protection | Integrated | ||
DC Switch | Integrated | ||
DC Overvoltage Protection | Integrated | ||
AC Overvoltage Protection | Integrated | ||
AFCI | Optional | ||
Rapid Shutdown | Integrated | ||
Remote Shutdown | Integrated | ||
General Data | |||
Operating Temperature (°C) | -35 ~ +60 | ||
Relative Humidity | 0~95% | ||
Max. Operating Altitude (m) | 3000 | ||
Cooling Method | Intelligent Ventilation Cooling | ||
User Interface | LCD, WLAN + APP | ||
BMS Communication | CAN | ||
Communication | RS485, WiFI + LAN + Bluetooth | ||
Communication Protocols | Modbus-RTU, Modbus-TCP | ||
Weight (kg) | 27 | 29 | 29 |
Dimensions (W x H x D mm) | 560 x 444.5 x 226 | ||
Topology | Non-isolated | ||
Protection Rating | IP66 | ||
Mounting Method | Wall Mounting |
Footnotes:
- ¹: Lithium batteries are usually of two types: LFP and ternary lithium battery.
- ²: When the photovoltaic input voltage is above 490V, the battery charge and discharge power will be gradually limited, and the power limitation will be removed once the input voltage is reduced.
- ³: When the input voltage is 560V-600V, the inverter will enter standby mode. The inverter will return to normal operating status when the voltage returns to the MPPT working voltage range.
- ⁴: Refer to the user manual for the MPPT voltage range at rated power.
- ⁵: The maximum input current per string is 16A. Or, for MPPT with two strings, the current of each string is 16A.
- *: Visit the GoodWe website for the latest certificates.
For more information, visit emea.goodwe.com. The data shown provides information on products offered in the EMEA region.