GoodWe ES Series 5kW Single Phase Hybrid Inverter
Product Overview
The GoodWe ES series of bi-directional energy storage inverters are designed for both on-grid and off-grid photovoltaic (PV) systems, offering intelligent control over energy flow. During daylight hours, the PV array generates electricity that can power local loads, feed into the grid, or charge the battery, based on system economics and configuration. Stored energy can be discharged during nighttime to meet load requirements, including inductive loads like air conditioners or refrigerators. The power grid can also be utilized to charge storage devices through the inverter. This system provides comprehensive intelligent energy management for maximum flexibility.
Key Features:
- ⚡️ Charge controller and inverter integrated
- ? Export control (Zero export)
- ⏱️ 8 ms UPS-level Switching
- ? Maximum charge and discharge up to 100A
- ?️ IP65 dustproof and waterproof
- ?️ Fanless design, long lifespan
The product is a compact, white inverter unit with multiple connection terminals at the bottom, designed for wall mounting.
Technical Data
GW3648 Series | GW5048 Series | ||||
---|---|---|---|---|---|
GW3648D-ES*7 | GW3648C-ES*7 | GW5048D-ES*8 | GW5048C-ES*8 | ||
Battery Input Data | |||||
Battery Type | Li-Ion | Li-Ion | Li-Ion | Li-Ion | |
Nominal Battery Voltage (V) | 48 | 48 | 48 | 48 | |
Max. Continuous Charging Current (A)*1 | 75 | 75 | 100 | 1 | 75 |
Max. Continuous Discharging Current (A)*1 | 75 | 75 | 100 | 100 | |
PV String Input Data | |||||
Max. Input Power (W) | 4950 | 4950 | 6700 | 6700 | |
Max. Input Voltage (V) | 580 | 580 | 580 | 580 | |
MPPT Operating Voltage Range (V) | 125~550 | 125~550 | 125~550 | 125~550 | |
Start-up Voltage (V) | 125 | 125 | 125 | 125 | |
Nominal Input Voltage (V) | 360 | 360 | 360 | 360 | |
Max. Input Current per MPPT (A) | 11/11 | 11/11 | 11/11 | 11/11 | |
Max. Short Circuit Current per MPPT (A)*9 | 13.8/13.8 | 13.8/13.8 | 13.8/13.8 | 13.8/13.8 | |
Number of MPP Trackers | 2 | 2 | 2 | 2 | |
Number of Strings per MPPT | 1 | 1 | 1 | 1 | |
AC Output Data (On-grid) | |||||
Nominal Apparent Power Output to Utility Grid (VA)*5 | 3680 | 3680 | 5000 | 5000 | |
Max. Apparent Power Output to Utility Grid (VA)*2 | 3680 | 3680 | 7360 | 9200 | |
Max. Apparent Power from Utility Grid (VA) | 230 | 230 | 230 | 230 | |
Nominal Output Voltage (V) | 50/60 | 50/60 | 50/60 | 50/60 | |
Nominal AC Grid Frequency (Hz) | 50/60 | 50/60 | 50/60 | 50/60 | |
Max. AC Current Output to Utility Grid (A) | 16*6 | 24.5 | 32 | 40 | |
Max. AC Current From Utility Grid (A) | ~1 (Adjustable from 0.8 leading to 0.8 lagging) | ~1 (Adjustable from 0.8 leading to 0.8 lagging) | ~1 (Adjustable from 0.8 leading to 0.8 lagging) | ~1 (Adjustable from 0.8 leading to 0.8 lagging) | |
Power Factor | <3% | <3% | <3% | <3% | |
Max. Total Harmonic Distortion | <3% | <3% | <3% | <3% | |
AC Output Data (Back-up) | |||||
Back-up Nominal Apparent Power (VA) | 3680 | 3680 | 4600 | 4600 | |
Max. Output Apparent Power (VA)*3 | 3680 | 3680 | 4600 | 4600 | |
Max. Output Current (A) | 16 | 16 | 20 | 20 | |
Nominal Output Voltage (V) | 230 (± 2%) | 230 (± 2%) | 230 (± 2%) | 230 (± 2%) | |
Nominal Output Frequency (Hz) | 50/60 (± 0.2%) | 50/60 (± 0.2%) | 50/60 (± 0.2%) | 50/60 (± 0.2%) | |
Output THDv (@Linear Load) | <3% | <3% | <3% | <3% | |
Efficiency | |||||
Max. Efficiency | 97.6% | 97.6% | 97.6% | 97.6% | |
European Efficiency | 97.0% | 97.0% | 97.0% | 97.0% | |
Max. Battery to AC Efficiency | 94.0% | 94.0% | 94.0% | 94.0% | |
MPPT Efficiency | 99.9% | 99.9% | 99.9% | 99.9% | |
Protection | |||||
PV Insulation Resistance Detection | Integrated | Integrated | Integrated | Integrated | |
Residual Current Monitoring | Integrated | Integrated | Integrated | Integrated | |
PV Reverse Polarity Protection | Integrated | Integrated | Integrated | Integrated | |
Anti-islanding Protection | Integrated | Integrated | Integrated | Integrated | |
AC Overcurrent Protection | Integrated | Integrated | Integrated | Integrated | |
AC Short Circuit Protection | Integrated | Integrated | Integrated | Integrated | |
AC Overvoltage Protection | Integrated | Integrated | Integrated | Integrated | |
General Data | |||||
Operating Temperature Range (°C) | -25~60 | -25~60 | -25~60 | -25~60 | |
Relative Humidity | 0~95% | 0~95% | 0~95% | 0~95% | |
Max. Operating Altitude (m) | 3000 | 3000 | 3000 | 3000 | |
Cooling Method | Natural Convection | Natural Convection | Natural Convection | Natural Convection | |
Display | LED & APP | LED & APP | LED & APP | LED & APP | |
Communication with BMS*4 | RS485; CAN | RS485; CAN | RS485; CAN | RS485; CAN | |
Communication with Meter | RS485 | RS485 | RS485 | RS485 | |
Communication with Portal | Wi-Fi | Wi-Fi | Wi-Fi | Wi-Fi | |
Weight (kg) | 28 | 28 | 30 | 30 | |
Dimension (W x H x D mm) | 516 x 440 x 184 | 516 x 440 x 184 | 516 x 440 x 184 | 516 x 440 x 184 | |
Noise Emission (dB) | <25 | <25 | <25 | <25 | |
Topology | Battery Isolation | Battery Isolation | Battery Isolation | Battery Isolation | |
Self-consumption at Night (W) | <13 | <13 | <13 | <13 | |
Ingress Protection Rating | IP65 | IP65 | IP65 | IP65 | |
Mounting Method | Wall Bracket | Wall Bracket | Wall Bracket | Wall Bracket | |
Country of Manufacture | China | China | China | China |
Footnotes:
- *1: The actual charge and discharge current also depends on the battery.
- *2: 4600 for VDE 0126-1-1 & VDE-AR-N4105 & NRS 097-2-1, 5100 for CEI 0-21 (GW5048D-ES); 4050 for CEI 0-21 (GW3648D-ES).
- *3: Peak output apparent power can be reached only if PV and battery power is enough.
- *4: CAN communication is configured by default. If 485 communication is used, please replace the corresponding communication line.
- *5: 4600 for VDE 0126-1-1 &VDE-AR-N4105 &NRS 097-2-1, 4600 for CEI 0-21 (GW5048D-ES).
- *6: 18 for CEI 0-21.
- *7: FOR AUSTRALIA ONLY. Model GW3648D-ES inverters are designed without DC switch. For inverters designed with DC switch, the model name should be GW3648C-ES.
- *8: FOR AUSTRALIA ONLY. Model GW5048D-ES inverters are designed without DC switch. For inverters designed with DC switch, the model name should be GW5048C-ES.
- *9: For Australia Max. Short Circuit Current per MPPT (A) please refer to 'Manufacturer declaration: short circuit current'.
- *: Under off-grid mode, then battery capacity should be more than 100Ah.
- *: When there is no battery connected, inverter starts feeding in only if string voltage is higher than 200V.
- *: Please visit GoodWe website for the latest certificates.