Feit Electric

Item #: STRP/4X1/4WY/LED/V2

IMPORTANT SAFETY INSTRUCTIONS AND INSTALLATION GUIDE

4X1 LINKABLE LED STRIP LIGHT

Important Safety Information

For your safety, always remember to:

These products may present a possible shock or fire hazard if improperly installed or attached in any way. Products should be installed in accordance with the owner's manual, current electrical codes and/or the current National Electric Code (NEC) actual.

⚠️ CAUTION: Risk of fire. Use only on 120/277 volt 60Hz circuits.

❗ WARNING: Use 120 volt 60Hz with power cord only. Do not use with dimmers.

⚠️ CAUTION: Turn off the main power at the circuit breaker before installing the fixture in order to prevent possible shock.

ℹ️ NOTICE: All electrical connections must be in accordance with local and National Electrical Code (N.E.C) standards. If you are unfamiliar with proper electrical wiring connections, obtain the services of a qualified electrician.

⚠️ CAUTION: Do not install on a radiant-heating ceiling. Do not install on a surface that does not provide a stable and mechanically sound surface.

✅ Suitable for damp locations

? Connect up to a maximum of 6 strip lights

❗ WARNING: Never combine installation of strip lights as plug-in or direct wire.

FCC Statement

Supplier's Declaration of Conformity: 47 CFR § 2.1077 Compliance Information

Responsible Party: Feit Electric Company 4901 Gregg Road, Pico Rivera, CA 90660, USA

Unique Identifier: STRP/4X1/4WY/LED/V2

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Any changes or modifications not expressly approved by the manufacturer could void the user's authority to operate the equipment. CAN ICES-005 (B).

Limited Warranty

This product is warranted to be free from defects in workmanship and materials for up to 5 years from date of purchase. If the product fails within the warranty period, please contact Feit Electric at info@feit.com, visit feit.com/contact-us or call 1-866 326-BULB (2852) for instructions on replacement or refund. REPLACEMENT OR REFUND IS YOUR SOLE REMEDY. EXCEPT TO THE EXTENT PROHIBITED BY APPLICABLE LAW, ANY IMPLIED WARRANTIES ARE LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY. LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES IS HEREBY EXPRESSLY EXCLUDED. Some states and provinces do not allow the exclusion of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state or province to province.

Pre-Installation

Tools Required

Hardware Included

[Note: Hardware not shown to actual size.]

Part Description Quantity
AAFixture1
BBPlastic Anchors2
CCMounting Screws2
DDWire Nuts1
EETerminal1
FFLinking Cable (12in)1
GG5 ft Power Cord1
HHScrew Hooks2
IIHanging Wire2
JJConnector Cover1
KKEnd Cap Cover1

[Diagram showing all hardware parts labeled AA through KK.]

Suspended Mount Installation (Hardwired)

  1. Turning off the power

    Turn the power OFF at the switch, fusebox, or circuit breaker. Do not plug in until complete with installation.

  2. Separating the cover from the body

    Carefully separate the fixture cover (AA) from the fixture body by pressing the fixture body inward so that the tabs can detach from the cover. [Diagram showing how to press the fixture body inward to release tabs.]

  3. Disconnecting the wiring

    After separating cover from body, unplug the output connector from the cover and unscrew the screw holding ground wire from the cover and save it. [Diagram showing disconnected wires and ground screw.]

  4. Removing one of the knockouts

    Determine the knockout that will be used (1, 2 or 3) when installing under the metal clad cable (not provided). [Diagram showing three knockouts labeled 1, 2, 3.]

  5. Preparing suspension hardware

    Mark the two keyhole mounting locations using the fixture's body onto the ceiling and drill a 1/4 in. pilot hole in the marked location. Insert the anchors (BB) into the drilled holes and screw in the mounting screw hooks (HH) into the anchors. [Diagram showing marking ceiling, drilling holes, inserting anchors, and screwing in hooks.]

  6. Suspending the light fixture

    Attach the hook side of the hanging wire (II) through the keyholes of the fixture (AA) and hang the fixture onto the hooks (HH) on the ceiling. [Diagram showing hanging wire attached to fixture and ceiling hooks.]

  7. Installing metal clad cable

    Align the metal clad cable (not provided) and insert supply wire through the knockout opening and secure with clamp connector (not provided) for 1/2 in. knockout. [Diagram showing metal clad cable inserted into knockout.]

  8. Making electrical connections

    Attach the terminal (EE) to the supply wire from the metal clad cable (not provided). Ensure the black and white wires will align with the black and white wires from the fixture (AA). Using the wire nut (DD) connect the ground wire from the metal clad cable (not provided) to the ground from the fixture's body. Reattach the output connector to the fixture's cover and screw down the ground wire from the fixture body to the fixture cover. [Diagram showing wire connections with terminal, wire nut, and ground screw.]

  9. Selecting the color temperature

    Select desired color temperature. See Color Changing Instructions section.

  10. Reassembling the cover to the body

    Align the tabs from one side and snap tabs form the opposite side. [Diagram showing how to reattach the cover.]

  11. Attaching the Connector Covers

    If the connectors at each end of the fixture are not being used to link additional fixtures then attach the connector cover (JJ) and/or end cap cover (KK) onto the fixture end caps. [Diagram showing connector and end cap covers being attached.]

Suspended Mount Installation (Powercord)

  1. Turning off the power

    Turn the power OFF at the switch, fusebox, or circuit breaker. Do not plug in until complete with installation.

  2. Preparing suspension hardware

    Mark the two keyhole mounting locations using the fixture's body onto the ceiling and drill a 1/4 in. pilot hole where you have marked. Insert the anchors (BB) in the drilled holes and screw in the mounting screw hooks (HH) in the anchors. [Diagram showing marking ceiling, drilling holes, inserting anchors, and screwing in hooks.]

  3. Suspending the light fixture

    Attach the hook side of the hanging wire (II) through the keyholes of the fixture (AA) and hang the fixture onto the hooks (HH) on the ceiling. [Diagram showing hanging wire attached to fixture and ceiling hooks.]

  4. Connecting the power cord

    Insert the power cord (GG) into the fixture's connector then plug into a 120V electrical outlet. Secure the power cord to the ceiling using the cord clips or cable raceway (not included). [Diagram showing power cord connection and securing to ceiling.]

  5. Selecting color temperature

    Carefully separate the fixture cover from the fixture body by pressing the fixture body inward so that the tabs can detach from the cover. Select desired color temperature. See Color Changing Instructions section. Reassemble the cover to the body by aligning the tabs from one side and snap tabs form the opposite side. [Diagram showing cover separation and reassembly.]

  6. Attaching the Connector Covers

    If the connector at the end of the fixture is not being used to link additional fixtures then attach the connector cover (KK). [Diagram showing connector cover attachment.]

J-Box Installation

  1. Turning off the power

    Turn the power OFF at the switch, fusebox, or circuit breaker. Do not plug in until complete with installation.

  2. Separating the cover from the body

    Carefully separate the fixture cover (AA) from the fixture body by pressing the fixture body inward so that the tabs can detach from the cover. [Diagram showing how to press the fixture body inward to release tabs.]

  3. Disconnecting the wiring

    After separating cover from body, unplug the output connector from the cover and unscrew the screw holding ground wire from the cover and save. [Diagram showing disconnected wires and ground screw.]

  4. Removing one of the knockouts

    Determine the knockout that will be used (1, 2 or 3) when installing under the J-box. [Diagram showing three knockouts labeled 1, 2, 3.]

  5. Preparing to mount

    Mark the two keyhole mounting locations using the fixture's body onto the ceiling and drill a 1/4 in. pilot hole where you have marked. Insert the anchors in the drilled holes and screw in the mounting screws in the anchors and leave 1/4 in. of the screw out. [Diagram showing marking ceiling, drilling holes, inserting anchors, and screwing in screws.]

  6. Installing J-box cover plate

    Feed the electrical wire from the J-box through the center opening of the J-box cover plate (sold separately) and secure with J-box screws. [Diagram showing J-box cover plate installation.]

  7. Mounting the light fixture

    Feed the electrical wire through the knockout hole and align the keyholes with the two mounting screws in the ceiling. Once screw head is through slide the fixture to secure into the keyhole slot and tighten mounting screws with a screwdriver. [Diagram showing fixture being mounted to ceiling screws.]

  8. Making electrical connections

    Attach the terminal (EE) to the supply wire from the metal clad cable (not provided). Ensure the black and white wires will align with the black and white wires from the fixture (AA). Using a wire nut (DD) connect the ground wire from the metal clad to the ground from the fixture's body. Reattach the output connector to the fixture's cover and screw down the ground wire from the fixture body to the fixture cover. [Diagram showing wire connections with terminal, wire nut, and ground screw.]

  9. Selecting the color temperature

    Select desired color temperature. See Color Changing Instructions section.

  10. Reassembling the cover to the body

    Align the tabs from one side and snap tabs form the opposite side. [Diagram showing how to reattach the cover.]

  11. Attaching the Connector Covers

    If the connectors at each end of the fixture are not being used to link additional fixtures then attach the connector cover (JJ) and/or end cap cover (KK) onto the fixture end caps. [Diagram showing connector and end cap covers being attached.]

Flush Mount Installation

  1. Turning off the power

    Turn the power OFF at the switch, fusebox, or circuit breaker. Do not plug in until complete with installation.

  2. Separating the cover from the body

    Carefully separate the fixture cover (AA) from the fixture body by pressing the fixture body inward so that the tabs can detach from the cover. [Diagram showing how to press the fixture body inward to release tabs.]

  3. Disconnecting the wiring

    After separating cover from body, unplug the output connector from the cover and unscrew the screw holding ground wire from the cover and save. [Diagram showing disconnected wires and ground screw.]

  4. Preparing to mount

    Mark the two keyhole mounting locations using the fixture's body onto the ceiling and drill a 1/4 in. pilot hole where you have marked. Insert the anchors in the drilled holes and screw in the mounting screws in the anchors and leave 1/4 in. of the screw out. [Diagram showing marking ceiling, drilling holes, inserting anchors, and screwing in screws.]

  5. Mounting the light fixture

    Align the keyholes with the two mounting screws in the ceiling. Once screw head is through slide the fixture to secure into the keyhole slot and tighten mounting screws with a screwdriver. [Diagram showing fixture being mounted to ceiling screws.]

  6. Selecting color temperature

    Select desired color temperature. See Color Changing Instructions section.

  7. Reassembling the cover to the body

    Align the tabs from one side and snap tabs form the opposite side. [Diagram showing how to reattach the cover.]

  8. Connecting the power cord

    Insert the power cord (GG) into the fixture's connector then plug into a 120V electrical outlet. Secure the power cord using cord clips or cable raceway (not included) to the ceiling. [Diagram showing power cord connection and securing to ceiling.]

  9. Attaching the Connector Covers

    If the connector at the end of the fixture is not being used to link additional fixtures then attach the connector cover (KK). [Diagram showing connector cover attachment.]

Linking

❗ WARNING: RISK OF ELECTRIC SHOCK. Disconnect power to the strip light before linking additional strip lights.

A maximum of 6 strip lights can be connected. The first light fixture needs to be plugged into an electrical outlet or direct wired to an electrical box.

Provide power to the fixtures only after all linking connections have been made.

Connect each additional fixture using either the linking cable (FF) or end-to-end with integrated connector on the fixture. Connect end-to-end with integrated connector on the fixture (see Fig. 1) or insert the linking cable (FF) (see Fig. 2) into the receptacle in the end of each fixture body (AA). When using the linking cable (FF), the maximum distance between two light fixtures is 12 inches.

[Figure 1: Diagram showing two fixtures (AA) connected end-to-end with an integrated connector.]

[Figure 2: Diagram showing two fixtures (AA) connected using a linking cable (FF).]

Connect up to a maximum of 6 strip lights.

[Note: For best results, fully insert the linking cable (FF) or the integrated connector into the receptacle in the end of the strip light (AA).]

❗ WARNING: RISK OF ELECTRIC SHOCK. If the receptacle on the end of the strip light is not used to link another fixture, the receptacle needs to be closed by the end cover (GG). Do not touch live parts inside the receptacle.

⚠️ CAUTION: If using the linking cable (FF) to connect the strip lights, affix the linking cable (FF) to the ceiling using cord clips or a cable raceway (not included).

Color Changing Instructions

Change the mood anytime.

Select SWITCH on the fixture before installation, then use your existing wall switch to customize your light. [Diagram showing fixture switch set to 'SWITCH' and a wall switch.]

Choose your favorite light.

Set your preferred shade of white from an integrated switch on the fixtures before installation. [Diagram showing fixture switch set to 5K, 4K, or 3K.]

Fixture Maintenance

  1. Please make sure the power is off before maintenance by turning the breaker off or removing the fuse from the fuse box.
  2. To avoid any damage to the product, please do not use any chemical solvents during the routine maintenance.
  3. Do not use liquid cleaner on the LEDs, LED driver or wiring inside the light fixture.
  4. To ensure better lighting, please clean the lamp periodically with a soft cloth.
Models: V2, 070524, B0CPTG7QT6 4x1 Linkable Led Strip Light, B0CPTG7QT6, 4x1 Linkable Led Strip Light, Led Strip Light, Strip Light

PDF preview unavailable. Download the PDF instead.

otevnsra2g0lwcmcsiyt Adobe PDF library 17.00

Related Documents

Preview Feit Electric Night Lights and Flashlights Product Catalog
Detailed product specifications and features for Feit Electric's range of night lights and flashlights, including model numbers, performance metrics, and design details.
Preview Feit Electric GLP24ADJS/32W/LED Installation and Grow Light Guide
Comprehensive installation instructions and usage guide for the Feit Electric GLP24ADJS/32W/LED LED Shop Light, covering setup, safety, maintenance, and optimal use as a grow light for plants.
Preview Feit Electric 13-Inch White Round Puff Fixture Installation Guide
Comprehensive installation and safety guide for the Feit Electric 13-inch White Round Puff LED Ceiling Fixture. Learn how to safely install and operate your new fixture, including color temperature selection and troubleshooting.
Preview Feit Electric FLD30/RGB/LED Multi-Color LED Flood Light Installation Guide
Comprehensive installation and safety guide for the Feit Electric FLD30/RGB/LED Multi-Color LED Flood Light with RF Remote Control. Learn about setup, operation, and features.
Preview Feit Electric 24-Inch Under Cabinet LED Light Installation Guide
Comprehensive guide for installing and operating the Feit Electric 24-inch under cabinet LED light, including safety instructions, parts list, and linking multiple fixtures.
Preview Feit Electric UCL36FP/5CCTCA Flat Panel Under Cabinet Light Installation Guide and Safety Instructions
Comprehensive guide for installing and operating the Feit Electric UCL36FP/5CCTCA Flat Panel Under Cabinet LED Light, including safety precautions, hardware details, and functional instructions.
Preview Feit Electric 2x2 LED Skylight Troffer Fixture with Selectable Color Temperatures Installation Guide
This document provides important safety instructions and an installation guide for the Feit Electric 2x2 LED Skylight Troffer Fixture with Selectable Color Temperatures (Model: TR2X2/SKY/5CCT/WH). It includes wiring diagrams, operating instructions, and warranty information.
Preview Feit Electric 16ft Smart LED Strip Light Quick Install Guide - Setup & Troubleshooting
Comprehensive quick install guide for the Feit Electric 16ft Smart LED Strip Light (TAPE16/RGBW/AG). Learn how to set up, connect to Wi-Fi, use the app, and troubleshoot common issues. Includes safety instructions and warranty information.