Feit Electric 2x2 LED Skylight Troffer Fixture with Selectable Color Temperatures

Important Safety Instructions and Installation Guide

Thank you for choosing Feit Electric. We strive to continually create quality products designed to enhance your home. Visit us online to see our full line of products available for your home improvement needs.

Safety Information

For your safety, always remember to:

This fixture is designed for use in a circuit protected by a fuse or circuit breaker. It is also designed to be installed in accordance with local electrical codes. If you are unsure about your wiring, consult a qualified electrician or local electrical inspector, and check your local electrical code.

NOTICE: All electrical connections must be in accordance with local and National Electrical Code (N.E.C.) standards. If you are unfamiliar with proper electrical wiring connections obtain the services of a qualified electrician.

Remove the fixture and the mounting package from the box and make sure that no parts are missing by referencing the illustrations on the installation instructions.

WARNING: RISK OF SHOCK. House electric current can cause painful shock or serious injury unless handled properly.

CAUTION: Turn off the main power at the circuit breaker before installing the fixture, in order to prevent possible shock.

WARNING: RISK OF FIRE. Before installing your lighting fixture, thoroughly review this installation manual. If you do not have sufficient electrical wiring experience have your fixture installed by a certified electrician. All electrical connections must be in accordance with Local and National Electrical Code (NEC) Standards. Reliable operating temperature is -13°F to 113°F / -25°C to 45°C. Suitable for Damp Locations. For more information including dimmer compatibility visit www.feit.com.

SUITABLE FOR OPERATION IN AMBIENT NOT EXCEEDING 45°C

FOR USE IN NON-FIRE-RATED INSTALLATIONS ONLY

Product Specifications:

FCC Statement

Supplier's Declaration of Conformity: 47 CFR § 2.1077 Compliance Information

Responsible Party: Feit Electric Company

4901 Gregg Road, Pico Rivera, CA 90660, USA

www.feit.com

Unique Identifier: TR2X2/SKY/5CCT/WH

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Any changes or modifications not expressly approved by the manufacturer could void the user's authority to operate the equipment.

Limited Warranty

This product is warrantied to be free from defects in workmanship and materials for up to 3 years from date of purchase. If the product fails within the warranty period, please contact Feit Electric at info@feit.com or visit feit.com/contact-us for instructions on replacement or refund. REPLACEMENT OR REFUND IS YOUR SOLE REMEDY. EXCEPT TO THE EXTENT PROHIBITED BY APPLICABLE LAW, ANY IMPLIED WARRANTIES ARE LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY. LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES IS HEREBY EXPRESSLY EXCLUDED. Some states and provinces do not allow the exclusion of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state or province to province.

Pre-Assembly

Tools Required (Not Included)

Hardware Included

Installation

  1. Turning off the Power: Turn the power OFF at the switch, fusebox, or the circuit breaker.
  2. Identifying the Wires:
    • Black - Hot/Live
    • White - Neutral
    • Green or Bare Copper - Ground

    Diagram showing wire connections: Ground, Hot/Live, Neutral

  3. Removing the Hole Punch:
    • Open the power supply box cover.
    • Carefully remove the knockout with a screw driver or punch.

    Diagram illustrating knockout removal.

  4. Connecting the Power Supply Wires:
    • Use the wire nuts (BB) to connect the three wires coming from the fixture (AA) to the supply wires.
    • See wiring diagram A or diagram B.

    Diagram showing wire nut connections.

    NOTE: Purple and Pink wires to be used with 0-10V dimmers only (purple +10V, pink -10V). Purple (+10V) - Purple from dimmer Pink (-10) - Pink from dimmer. See wiring diagram B.

  5. Bending the Hanging-Hooks: Bend the hanging-hooks by 90°, as shown below.

    Diagram showing hanging-hooks bent at 90 degrees.

  6. Installing the Fixture:
    • Remove the ceiling tile where you will install the 2x2 Troffer.
    • Place the panel into the ceiling and use hanging-hooks to stabilize the panel on the T-Bar.

    Diagram showing fixture placement in ceiling.

  7. Turning On the Power: Turn on the fusebox or circuit breaker and the power at the wall switch.

Wiring for a Standard Wall Switch

WIRING DIAGRAM A

Diagram showing wiring connections for a standard wall switch: Supply Line (Black) to Line (Black) on fixture, Supply Neutral (White) to Neutral (White) on fixture, Supply Grounding (Green or Yellow) to J-Box Grounding (Green or Bare Copper) on fixture, using twist-on wire connectors.

Wiring for 0-10V Dimmer

WIRING DIAGRAM B

Diagram showing wiring connections for a 0-10V dimmer: Supply Line (Black) to Line (Black) on fixture, Supply Neutral (White) to Neutral (White) on fixture, 0-10V Dimmer Purple (+10V) to Purple (+10V) on fixture, 0-10V Dimmer Pink (-10V) to Pink (-10V) on fixture, Supply Grounding (Green or Yellow) to J-Box Grounding (Green or Bare Copper) on fixture, using twist-on wire connectors.

Operating the Fixture

NOTE: If the unit is turned off for more than 10 seconds, the mode will automatically revert to the default mode of Mode 1 (Skylight).

Changing the Color Settings

Visual representation of color temperature selection: Bright White (3000K), Neutral White (3500K), Cool White (4000K), Daylight (5000K), Daylight Deluxe (6500K).

When the slide switch is set to 3000K, the color temperature is set to Bright White.

When the slide switch is set to 3500K, the color temperature is set to Neutral White.

When the slide switch is set to 4000K, the color temperature is set to Cool White.

When the slide switch is set to 5000K, the color temperature is set to Daylight.

When the slide switch is set to 6500K, the color temperature is set to Daylight Deluxe.

NOTE: The color temperature is pre-set to 4000K.

Need Help?

Thank you for your purchase. Questions, comments or feedback? We'd love to hear from you.

Visit feit.com/help for support or connect with us:

Models: TR2X2_SKY_5CCT_WH, 012025, TR2X2 LED Skylight Drop Ceiling Light Fixture, TR2X2, LED Skylight Drop Ceiling Light Fixture, Skylight Drop Ceiling Light Fixture, Drop Ceiling Light Fixture, Ceiling Light Fixture, Light Fixture, Fixture

PDF preview unavailable. Download the PDF instead.

lavlub8ntrodwbyaw2uc Adobe PDF library 17.00

Related Documents

PreviewFeit Electric S10.5DFL/5CCT/MM/BZ: 5000 Lumens Motion Activated Dual Head LED Security Flood Light Installation Guide
Comprehensive installation guide and safety instructions for the Feit Electric S10.5DFL/5CCT/MM/BZ motion activated dual head LED security flood light. Learn about setup, operation, troubleshooting, and specifications.
PreviewFeit Electric 16 ft. Color Selectable LED Tape Light (UCL192/FLEX/5CCT) - Installation and Operation Guide
Comprehensive guide for the Feit Electric 16 ft. Color Selectable LED Tape Light (Model UCL192/FLEX/5CCT). Includes important safety instructions, step-by-step installation, pre-assembly details, hardware list, technical specifications, and operating instructions for dimming and color temperature control.
PreviewFeit Electric 24-Inch Under Cabinet LED Light Installation Guide
Comprehensive guide for installing and operating the Feit Electric 24-inch under cabinet LED light, including safety instructions, parts list, and linking multiple fixtures.
PreviewFeit Electric LEDR4HOJBX/6WYCA Installation Guide and Safety Instructions
Comprehensive guide for installing the Feit Electric LEDR4HOJBX/6WYCA recessed lighting fixture, including safety precautions, package contents, electrical ratings, color selection, and installation steps.
PreviewFeit Electric LEDR6XT/6WYCA/6: 6-Inch Color Selectable LED Downlight Installation Guide
Comprehensive installation guide for the Feit Electric LEDR6XT/6WYCA/6 6-inch recessed LED downlight. Learn about safety, package contents, product ratings, color selection, and step-by-step installation instructions.
PreviewFeit Electric 13-Inch White Round Puff Fixture Installation Guide
Comprehensive installation and safety guide for the Feit Electric 13-inch White Round Puff LED Ceiling Fixture. Learn how to safely install and operate your new fixture, including color temperature selection and troubleshooting.
PreviewFeit Electric 5-6 Inch LED Recessed Downlight with 5 White Color Temperature Select: Safety and Installation Guide
This guide provides important safety instructions and installation steps for the Feit Electric 5-6 Inch LED Recessed Downlight. Learn how to choose color temperature, adjust torsion springs, and install the downlight with or without a socket adapter. Includes FCC statement and limited warranty information.
PreviewFeit Electric 4X1 Linkable LED Strip Light Installation Guide and Safety Instructions
Comprehensive guide for installing and using the Feit Electric 4X1 Linkable LED Strip Light, including safety precautions, installation methods (hardwired, power cord, J-box, flush mount), linking instructions, color temperature selection, and maintenance.