PRECISE COLLECTION RECESSED STANDARD ROUGH-IN SECTIONS SERIES ELA LCRIS

CAUTION: For safety and proper operation, read and follow instructions carefully before installation.

Parts Description

  • ① Cover Can
  • ② Bar Hanger Bracket (2)
  • ③ Bar Hanger Bracket Screws (4)
  • ④ Typical Conduit Knockout
  • ⑤ Bar Hanger Locking Screw (2)
  • ⑥ Alternate Mounting Holes
  • ⑦ Bar Hanger (4)
  • ⑧ T-Bar Clips (4)
  • ⑨ Trim Ring Mounting Screw (6)
  • ⑩ Trim Ring Half (2)
  • ⑪ Trim Ring Mounting Holes
  • ⑫ Side Flanges
  • ⑬ Cup Washer
  • ⑭ Green Ground Screw
  • ⑮ T-Bar Clip Screws (4)

Important Safeguards

  • READ AND FOLLOW ALL SAFETY INSTRUCTIONS
  • Before wiring to power supply, turn off electricity at fuse or circuit breaker.
  • Disconnect A.C. power before servicing.
  • All servicing should be performed by qualified personnel.
  • Consult your local building code for approved wiring and installation.
  • Do not use outdoors.
  • Do not mount near gas or electric heater.
  • Fixture must be grounded to avoid potential electric shock.
  • Equipment should be mounted in location and at heights where it will not readily be subjected to tampering by unauthorized personnel.
  • The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition.
  • Do not use this equipment for other than intended use.

SAVE THESE INSTRUCTIONS

Installation: Rough-In Section Ceiling Mount

Note: If painting or plastering after trim ring is installed, mask mounting holes on trim. Tape provided in prepack.

Bar hangers are adjustable from 14 1/2" to 24". Reverse bar hangers 90 degrees by removing bar hanger bracket screws (3), and moving bar hanger brackets (2) and bar hangers (7) to the alternate end mounting holes (6). Reattach with bar hanger bracket screws (3). Break along the score lines of bar hangers to reduce spacing to 12".

Position the rough-in section with the end flanges (2) of the cover can (1) flush with the upper surface of the ceiling material. Secure by tightening the bar hanger locking screws (5).

Wood Joists:

Adjust bar hangers to fit against joists. Drive nailer tabs into wood. See Figure 1B.

Suspended Ceilings:

Fasten the ends of the bar hangers securely to T-bars using T-bar clips (8) and clip screws (15). See Figure 1A.

Close-In Dry Ceiling:

Cutout hole in ceiling material should not exceed 4 1/2" x 13 3/4" (max.). Note: The top of the cover can (1) may be used as a template to trace cutout onto ceiling material. Install trim ring halves (10) and secure with trim ring mounting screws (9).

Wet Ceiling:

Do not plaster inside the plaster ring opening. Install trim ring halves (10) and secure with trim ring mounting screws (9).

Diagram Reference: Figure 1 shows an exploded view of the rough-in section components. Figure 2 illustrates the rough-in section mounted in a ceiling, showing dimensions and part callouts. Figure 3 shows a suspended ceiling installation detail.

Installation: Rough-In Section Back Mount

Note: When back mounting, Bar hangers (7) are adjustable from 14 1/2" to 24". Position the rough-in section with the side flanges (12) of the cover can (1) flush with the inner (stud side) surface of wall material.

Wood Studs:

Adjust bar hangers to fit against studs. Secure by tightening the locking screws (5). Drive nailer tabs into wood.

Metal Studs:

Installation is the same as for wood studs except that sheet metal screws (not provided) should be used to fasten the ends of the bar hanger to the studs. These screws should have a minimum pullout rating of 30 pounds.

Back Mounting Above Doorway:

Before installing the rough-in section above a doorway, make certain that there will be adequate clearance between the bottom of the sign panel and the top of the door. See Figure 2 for sign panel dimensions.

See Figure 3 for cases where the rough-in section extends above the ceiling line (as with suspended ceilings). Allow bar hangers to be properly secured.

Close-In Dry Wall:

Cutout hole in wall material should not exceed 4 1/2" x 13 3/4" (max.). Note: The top of the cover can (1) may be used as a template to trace cutout onto wall material. Install trim ring halves (10) and secure with trim ring mounting screws (9).

Wet Wall:

Do not plaster inside the plaster ring opening. Install trim ring halves (10) and secure with trim ring mounting screws (9).

Note for proper fit: Position the rough-in section with the end flanges (12) of the cover can (1) flush with the upper surface of the ceiling material. Install trim ring halves (10) with their end flanges flush with the lower surface of the ceiling material. Spread the two trim ring halves (10) as far apart as possible during installation. (FIG 1)

Diagram Reference: Figure 2 illustrates the rough-in section mounted in a wall, showing dimensions and part callouts. Figure 3 shows a detail of the rough-in section extending above a suspended ceiling line.

Installation: Rough-In Section End Mount

(Requires End Mount Panel Assembly) (Ref: Fig. 1 and 4)

Remove bar hanger bracket screws (3) and relocate bar hanger brackets (2) with bar hangers (7) to alternate mounting holes (on ends of cover can) and secure using same screws. Bar hangers are adjustable from 14 1/2" to 24". Break along bar hanger score lines to reduce spacing to 12". Rough-in section may be off-centered if necessary, but bar hangers should be secured together with bar hanger locking screws (5).

Position the rough-in section with the side flanges (12) of the cover can (1) flush with the inner (stud side) surface of wall material.

Wood Studs:

Adjust bar hangers to fit against studs. Secure by tightening the locking screws (5). Drive nailer tabs into wood.

Metal Studs:

Installation is the same as for wood studs except that sheet metal screws (not provided) should be used to fasten the ends of the bar hanger to the studs. These screws should have a minimum pullout rating of 30 pounds.

Close-In Dry Wall:

Cutout hole in wall material should not exceed 4 1/2" x 13 3/4" (max.). Note: The top of the cover can (1) may be used as a template to trace cutout onto wall material. Install trim ring halves (10) and secure with trim ring mounting screws (9).

Wet Wall:

Do not plaster inside the plaster ring opening. Install trim ring halves (10) and secure with trim ring mounting screws (9).

Diagram Reference: Figure 4 shows the rough-in section mounted to a wall stud, with part callouts.

Models: EMCSA00679, EMCSA00679 Aluminum Edge Lit Exit Sign, EMCSA00679, Aluminum Edge Lit Exit Sign, Lit Exit Sign, Sign

File Info : application/pdf, 6 Pages, 193.66KB

PDF preview unavailable. Download the PDF instead.

emcsa00679,-rev-b GPL Ghostscript 9.04

Related Documents

Preview Titan Series ELT24C, ELT36C Emergency Lighting Unit Installation Guide
Installation guide for Titan Series ELT24C and ELT36C emergency lighting units by Lithonia Lighting. Covers safety, mounting, wiring, inspection, maintenance, battery information, and warranty.
Preview Lithonia Lighting ELA Q LED Quantum Thermoplastic Emergency Light
Specifications and installation information for the Lithonia Lighting ELA Q LED Quantum Thermoplastic Emergency Light, including features, construction, optics, listings, warranty, and ordering details.
Preview Lithonia Lighting 2GTL LED Recessed Troffer - Features, Specifications, and Ordering
Detailed information on the Lithonia Lighting 2GTL LED recessed troffer, including features, construction, electrical specifications, installation guidelines, and ordering options. Learn about its energy efficiency, lumen management, and control capabilities.
Preview Lithonia Lighting TITAN SERIES ELT50, ELT50 N Installation Instructions
Comprehensive installation, wiring, inspection, and maintenance guide for Lithonia Lighting TITAN SERIES ELT50 and ELT50 N emergency lighting fixtures. Includes safety precautions, mounting instructions, wiring diagrams, and battery information.
Preview Lithonia Lighting 2GTL Series LED Recessed Troffer - Product Specifications and Ordering
Explore the Lithonia Lighting 2GTL Series 2'x4' LED Recessed Troffer. This document details features, specifications, ordering information, performance data, and photometrics for this energy-efficient lighting solution suitable for commercial and institutional applications.
Preview EXTL EXTREME Emergency Lighting Unit Installation and Maintenance Manual
This manual provides detailed instructions for the installation, testing, and maintenance of the EXTL EXTREME Emergency Lighting Unit by Lithonia Lighting. It covers safety precautions, mounting procedures, component replacement, troubleshooting, and wiring diagrams.
Preview Lithonia Lighting 2GTL LED Recessed Troffer - Specifications and Ordering
Comprehensive technical specifications, performance data, ordering information, and features for the Lithonia Lighting 2GTL 2'x4' LED recessed troffer, highlighting its A+ capable design, lumen packages, and nLight control compatibility.
Preview Lithonia Lighting 2BLT4R LED Relight Troffer: Features, Specifications, and Controls
The Lithonia Lighting 2BLT4R is a 2'x4' LED relight troffer designed for efficient retrofitting of existing fluorescent fixtures. It offers high lumen output, multiple diffuser options, integrated nLight and SensorSwitch controls, and optional emergency battery packs.