Munters IceDry® 1400

Desiccant dehumidification units for frost-free storage

Frost-free cold storage can be a reality with the installation of an IceDry dehumidifier. When an IceDry unit is installed, accumulated ice and frost will be significantly reduced or eliminated.

Features

  • Thermostat controlled heating fan within the electrical panel
  • Special reactivation fan in an insulated fan box with a heating cable
  • Reversible panel construction (provides installation flexibility)

IceDry is the only dehumidifier that has been developed especially for installation inside cold storage areas. The tough, cold environment demands special features created to ensure reliable and energy efficient operation of the unit.

Installation of the unit is simple. The IceDry unit is placed close to a wall and ducting around the unit is minimal. Reactivation air is taken from the room next to the cold storage area. Immediately after being started, the unit will begin to reduce ice and frost.

Unique benefits of the IceDry unit include:

  • Reduced electrical and mechanical failures, less downtime
  • Lower maintenance costs
  • Reduced defrost requirements
  • Increased efficiency of evaporators

Suggested specification guide

Dehumidifier shall be of the non-cycling sorption type with a single desiccant rotary structure. The unit will be equipped with an internally sealed rotor unit. The rotor casing shall be constructed of durable thermoset plastic and contain isolated sections that will provide a precise balance for dehumidification, reactivation, and heat recovery airflows. The metal frame and access panels shall be constructed from corrosion resistant ALUZINK®. Suitable access panel shall allow access for inspection or servicing without disconnecting ducting or electrical wiring.

The rotary structure shall be a monolithic fabricated extended surface consisting of inert silicates reinforced with uniform diameter glass fibers for maximum strength. The fabricated structure shall be smooth and continuous in the direction of airflow without interruptions or sandwich layers which restrict airflow or create a leakage path at joining surfaces. Desiccant shall not channel, cake or fracture due to repeated temperature and moisture cycling. The materials of construction shall be non-toxic and NFPA 225-ASTM E84 compliant.

Full face contact pressure seals shall be provided to separate the process and reactivation airstreams and eliminate detrimental leakage of air or moisture with static pressure differentials of up to 3" of water gauge.

Dehumidifier shall be factory assembled, fully automatic, complete with HoneyCombe® desiccant wheel, reactivation heaters, reactivation energy control system, roughing filters, motors, fans, non-racheting desiccant drive unit, automatic controller and all components' auxiliaries. Reactivation Energy Modulation shall be stepless solid state proportioning type. Dehumidifier shall be functionally tested at the manufacturer's factory and shipped complete with all components necessary to maintain normal operation.

Technical Specifications*

  • Process Volume: 825 scfm
  • Maximum Reactivation Volume: 225 scfm
  • Maximum FLA: 24.4A @ 230V/3/60Hz, 13.2A @ 460V/3/60Hz
  • Maximum noise level unducted (dBA): 80
  • 30% process and reactivation filters
  • Fan External Static Pressure (in. w.g.): Process: 1.0, Reactivation: 0.5
  • Performance: For Process Inlet Temperature ≤10°F, Process Outlet Moisture = 0.6 gr/lb, Process Temperature Rise is 16°F
  • For performance ≥10°F, consult factory.

*Continual engineering and research for product improvement may result in design and specification changes. Consult factory for certified technical data.

Dimensions

Max length (in.) Max width (in.) Max height (in.) Max weight (lbs.)
34 24 60 350

Diagrams

Left Side View: Shows dimensions and air inlets/outlets. Process Air Inlet is on the left, Reactivation Air Outlet is on the right. Detail A indicates a specific measurement point.

Front View: Displays the front of the unit with Process Air Outlet at the top and Reactivation Air Inlet at the bottom.

Right Side View: Illustrates the right side, with Reactivation Air Outlet at the top and Process Air Inlet at the bottom.

Internal Diagram: A diagram shows the airflow path. Reactivation air enters, passes through a wheel, and exits as dry air. Wet air enters, passes through the wheel, and exits as process air. The patented HoneyCombe® wheel design is highlighted for its vast surface area for desiccant.

Find your nearest Munters office at www.munters.com.

Munters reserves the right to make alterations to specifications, quantities, etc., for production or other reasons, subsequent to publication. Munters AB, 2021

Models: IceDry 1400 Dehumidification Units

File Info : application/pdf, 2 Pages, 1.81MB

PDF preview unavailable. Download the PDF instead.

munters-icedry1400

References

Adobe PDF Library 15.0 Adobe InDesign 16.3 (Macintosh)

Related Documents

Preview Munters ICA: Integrated Custom Air Handler Desiccant Dehumidifier
Explore the Munters ICA, an integrated custom air handler desiccant dehumidifier offering advanced humidity control, energy efficiency, and high configurability for industrial and manufacturing applications. Learn about its features, advanced design, and custom options.
Preview Munters MCS300 Dehumidifier: Features, Specifications, and Performance
Detailed information on the Munters MCS300 dehumidifier with air cooled condenser, including product description, rotor technology, technical specifications, features, and performance data.
Preview Munters DEW 50 Mobile Dehumidifier: Product Overview and Specifications
Detailed information on the Munters DEW 50 mobile desiccant dehumidifier, highlighting its advantages, features, technical specifications, dimensions, and applications for humidity control in various environments.
Preview Munters A40G Desiccant Dehumidifier: Specifications and Installation Guide
Comprehensive technical specifications, operational details, and installation guidelines for the Munters A40G Desiccant Dehumidification Equipment used at Pacific Coliseum.
Preview Munters HCD-1125 Series Desiccant Dehumidifier - Technical Specifications and Product Information
Detailed product information, features, advantages, dimensions, and technical specifications for the Munters HCD-1125 Series Modular Desiccant Dehumidifier units.
Preview Munters HC-150 Desiccant Dehumidifier: Technical Specifications and Overview
Detailed technical specifications, features, and advantages of the Munters HC-150 desiccant dehumidifier, designed for efficient humidity control in various industrial applications.
Preview ComDry M160L User Manual - Munters Desiccant Dehumidifier
Comprehensive user manual for the Munters ComDry M160L desiccant dehumidifier. Learn about installation, operation, safety, maintenance, and technical specifications.
Preview Munters Dehumidifier ML420-1350, MLT800-1400 User Manual
User manual for Munters Dehumidifier models ML420-1350 and MLT800-1400, covering installation, operation, maintenance, and technical specifications.