SECOP KLF8.6CND Compressor Technical Data

Model Designation: KLF8.6CND

Sales Code: 106H2910

Power Supply: 220-240V/50Hz 1~

Compressor Design

Specification Value
Oil type Polyolester
Oil viscosity 19,2 cSt
Oil quantity 239 cm³ / 8,1 fl.oz
Refr. charge - tech. limit 200g / 7,1oz
Free gas volume comp. 1575 cm³ / 53,3 fl.oz
Weight 9,2kg / 20,3lbs
Motor protection external
Winding resistance main 8,4 Ω (at 25°C)
Winding resistance aux 17,4 Ω (at 25°C)
Max. winding temp. 125°C / 257°F
Max. discharge temp. 130°C / 266°F

Image: A SECOP KL-Series compressor unit.

General Configurations (KLF8.6CND)

Configuration Item Value
Motor configuration CSIR
Power supply (nominal) 220-240V/50Hz
Number of phases 1
Voltage range 198-254V
Approvals VDE
Starting torque HST
Note Electrical equipment is included and pre-assembled to compressor.

Applications (KLF8.6CND)

Application Detail Value
Refrigerant R290
Application Type LBP+MBP
System cooling fan 3m/s
Hot gas defrost OK
Long interval pull down OK

Electrical Data (KLF8.6CND)

Electrical Detail Value
Starting device type relay
Run capacitor -/-
Start capacitor 80µF
LRA (locked rotor amps / 4s/ U(N)) 14,3A
RLA (rated load amps / 1s/ U(N)) 2,3A
Cut in current (U(N))

Compressor Dimensions

Housing Dimensions

Dimension Value (mm) Value (in)
A Height 182 7,17
B Height 175 6,89
C Length shell 198 7,8
D Length w. cover 238 9,37
E Width 160 6,3

Diagram: Schematic showing compressor dimensions labeled A (Height), B (Height), C (Length shell), D (Length with cover), and E (Width). Also shows connection points labeled X (Suction), Y (Discharge), Z (Process), and orientation indicators.

Connectors Data

Connection Type
Suction (X) Discharge (Y) Process (Z)
Diameter [mm] øi 8,11-8,29 øi 6,11-6,29 øi 6,11-6,29
(i:inside, o:outside) [in] øi 0,32-0,33 øi 0,24-0,25 øi 0,24-0,25
Material copper copper copper
Horizontal angle ±2° 35° 13°
Vertical angle ±2° 30° 40° 145°
Position l/h/w [mm] 119/73/59 117/107/66 -88/101/71
[in] 4,7/2,9/2,3 4,6/4,2/2,6 -3,5/4/2,8
Straight tube l. [mm] 14 14 14
[in] 0,5 0,5 0,5

Compressor Fixation

Baseplate Large holes Small holes
[mm] [inch] [mm] [inch] [mm] [inch]
Bl 204 8.03 Ll 165 6.5 Sl 170 6.7
Bw 132 5.2
ØE Ø 9.7 Ø 0.38
Lw 101.6 4 ØL Ø 19 Ø 0.75 Sw 70 2.76
ØS Ø 16 Ø 0.63

Diagram: Compressor fixation points illustration showing baseplate dimensions (Bl, Bw, Lw, Sw) and hole sizes (ØE, ØL, ØS, Sl). Includes labels for suction (SI), discharge (BI), and other points.

Diagram: Bolt joint illustration showing how the compressor base is attached using a bolt, washer, nut, sleeve, cabinet base, and rubber grommet.

Diagram: Snap-on connection illustration showing attachment via a clip, steel pin, compressor base, cabinet base, and rubber grommet.

Mounting Accessories

Accessory Type Part Number (Single) Part Number (Multi-pack)
Bolt joint | M6 | Ø16mm 118-1917 118-1918
Bolt joint | ø1/4" | ø16mm 118-1946
Bolt joint | ø1/4" | ø19mm 118-1949
Snap-on | Ø7,3 | Ø16mm 118-1947 118-1919

Application Notes

Provision for PE Grounding is located at the PE Stamp on the compressor.

Ambient/Machine Room Temperatures

Environment Minimum Maximum
Ambient temperature range 10 - 43°C 50 - 110°F
Machine room temperature range 10 - 48°C 50 - 119°F

Compressor Cooling: fan 3m/s

Operation Pressure Range

This section presents graphical data illustrating the compressor's operation pressure ranges. The graphs show condensing pressure versus evaporation pressure under continuous and transitory operation conditions.

Graph 1: Condensing Pressure vs. Evaporation Pressure

Graph 2: Condensing Pressure vs. Evaporation Pressure (Alternative Scale)

Diagram: Electrical accessories and wiring diagram showing components like a current relay (a5), start capacitor (c), and cover/clamp/screws assemblies (b, d).

Optimization + Standard Conditions

Performance data under various standard conditions for R290, 220V/50Hz, CSIR, fan 3m/s, VDE.

Evaporating Pressure (Saturation Temp.) Condensing Pressure (Saturation Temp.) Return Gas Temp. Liquid Temp. Cooling Capacity COP EER Power Consumption Ref. mass flow [kg/h]
[W] [Btu/h] [kcal/h] [W/W] [Btu/Wh] [kcal/Wh] [W] [A]
[°C] -23
[°F] -10
54
130
32
90
32
90
455,6 1556 392,1 1,61 5,48 1,38 283,7 1,77 4,61 ASHRAE LBP
[°C] -25
[°F] -13
55
131
32
90
55
131
342,5 1170 294,7 1,25 4,27 1,08 273,8 1,74 4,26 cecomaf LBP
[°C] -35
[°F] -31
40
104
20
68
40
104
253,2 865 217,9 1,27 4,35 1,10 198,6 1,51 2,89 EN12900 LBP
[°C] -7
[°F] 20
54
130
35
95
46
115
791,6 2703 681,2 2,00 6,83 1,72 396,0 2,19 9,03 ASHRAE MBP
[°C] -10
[°F] 14
55
131
32
90
55
131
631,8 2158 543,8 1,69 5,76 1,45 374,9 2,11 7,99 cecomaf MBP
[°C] -10
[°F] 14
45
113
20
68
45
113
701,4 2395 603,6 2,05 7,01 1,77 341,9 1,98 8,61 EN12900 MBP

Performance Tables

Performance data for R290, 220V/50Hz, CSIR, fan 3m/s, VDE.

Cooling Capacity COP EER Power Consumption Ref. mass flow [kg/h]
pe [°C] [°F] [W] [Btu/h] [kcal/h] [W/W] [Btu/Wh] [kcal/Wh] [W] [A]
cond. pressure
pc= 45/113
-40 -40 182,8 624 157,3 1,03 3,52 0,89 177,4 1,46 2,04
-35 -31 243,8 833 209,8 1,20 4,09 1,03 203,4 1,52 2,73
-25 -13 397,2 1357 341,9 1,54 5,25 1,32 258,4 1,69 4,48
-15 5 603,3 2060 519,2 1,92 6,55 1,65 314,5 1,88 6,86
-5 23 875,1 2989 753,1 2,38 8,12 2,04 368,3 2,08 10,08
liquid temp
Tliq= 45/113
0 32 1039,8 3551 894,8 2,64 9,03 2,28 393,2 2,18 12,06
10 50 1434,7 4900 1234,7 3,28 11,21 2,83 437,0 2,36 16,95
cond. pressure
pc= 55/131
-40 -40 150,2 513 129,3 0,81 2,76 0,70 185,7 1,48 1,85
-35 -31 206,3 704 177,5 0,97 3,31 0,83 212,9 1,55 2,55
-25 -13 342,5 1170 294,7 1,25 4,27 1,08 273,8 1,74 4,26
-15 5 521,9 1782 449,1 1,53 5,23 1,32 340,5 1,98 6,56
-5 23 757,5 2587 651,9 1,85 6,32 1,59 409,5 2,25 9,65
liquid temp
Tliq= 55/131
0 32 900,5 3075 775,0 2,03 6,93 1,75 443,8 2,39 11,57
10 50 1245,0 4252 1071,4 2,44 8,34 2,10 509,8 2,67 16,32

PDF preview unavailable. Download the PDF instead.

klf86cnd 106h2910 r290 220v 50hz 08-2025 ds Microsoft Excel für Microsoft 365

Related Documents

Preview SECOP KLF6.6CND Compressor Technical Data Sheet
Detailed technical specifications, dimensions, electrical data, performance tables, and configuration options for the SECOP KLF6.6CND compressor, utilizing R290 refrigerant.
Preview SECOP KLF5.6CND Compressor Technical Data Sheet
Detailed technical specifications, performance data, dimensions, and electrical information for the SECOP KLF5.6CND compressor by SECOP.
Preview Secop KLF5.6CND Compressor Technical Data Sheet & Overview
Comprehensive technical specifications, performance data, dimensions, and configuration details for the Secop KLF5.6CND 220-240V 50Hz RSCR compressor. Includes single pack contents and service information.
Preview Secop PL35F Compressor Technical Data Sheet - 220-240V 50Hz RSIR
Detailed technical specifications, dimensions, performance data, and wiring diagrams for the Secop PL35F hermetic compressor, designed for 220-240V, 50Hz operation with R134a refrigerant. Includes optimization conditions and performance tables.
Preview Secop KLF5.6CND Compressor Technical Data and Specifications
Comprehensive technical specifications, dimensions, performance data, configuration details, and service information for the Secop KLF5.6CND compressor, designed for 220-240V, 50Hz operation with R290 refrigerant.
Preview Secop SC21F Compressor Technical Data and Specifications
Comprehensive technical datasheet for the Secop SC21F hermetic compressor, detailing its specifications, dimensions, electrical data, operating limits, and performance tables for R134a refrigerant. Includes single pack contents and general compressor information.
Preview Secop SC10DL Compressor: Technical Data, Specifications, and Performance
Comprehensive technical datasheet for the Secop SC10DL compressor (Model 104L2525), detailing its specifications, dimensions, electrical data, performance tables, and operating limits for refrigerants like R404A, R507, and R407C. Includes single pack component list and service information for R290.
Preview Secop NL7CN Compressor: Technical Specifications, Datasheet, and Performance Data
Detailed technical specifications, performance data, accessories, and service information for the Secop NL7CN LBP/MBP R290 compressor (220-240V 50Hz). Includes EN 12900 and ASHRAE LBP ratings.