SECOP KLF8.6CND Compressor Technical Data
Model Designation: KLF8.6CND
Sales Code: 106H2910
Power Supply: 220-240V/50Hz 1~
Compressor Design
Specification | Value |
---|---|
Oil type | Polyolester |
Oil viscosity | 19,2 cSt |
Oil quantity | 239 cm³ / 8,1 fl.oz |
Refr. charge - tech. limit | 200g / 7,1oz |
Free gas volume comp. | 1575 cm³ / 53,3 fl.oz |
Weight | 9,2kg / 20,3lbs |
Motor protection | external |
Winding resistance main | 8,4 Ω (at 25°C) |
Winding resistance aux | 17,4 Ω (at 25°C) |
Max. winding temp. | 125°C / 257°F |
Max. discharge temp. | 130°C / 266°F |
Image: A SECOP KL-Series compressor unit.
General Configurations (KLF8.6CND)
Configuration Item | Value |
---|---|
Motor configuration | CSIR |
Power supply (nominal) | 220-240V/50Hz |
Number of phases | 1 |
Voltage range | 198-254V |
Approvals | VDE |
Starting torque | HST |
Note | Electrical equipment is included and pre-assembled to compressor. |
Applications (KLF8.6CND)
Application Detail | Value |
---|---|
Refrigerant | R290 |
Application Type | LBP+MBP |
System cooling | fan 3m/s |
Hot gas defrost | OK |
Long interval pull down | OK |
Electrical Data (KLF8.6CND)
Electrical Detail | Value |
---|---|
Starting device type | relay |
Run capacitor | -/- |
Start capacitor | 80µF |
LRA (locked rotor amps / 4s/ U(N)) | 14,3A |
RLA (rated load amps / 1s/ U(N)) | 2,3A |
Cut in current (U(N)) |
Compressor Dimensions
Housing Dimensions
Dimension | Value (mm) | Value (in) |
---|---|---|
A Height | 182 | 7,17 |
B Height | 175 | 6,89 |
C Length shell | 198 | 7,8 |
D Length w. cover | 238 | 9,37 |
E Width | 160 | 6,3 |
Diagram: Schematic showing compressor dimensions labeled A (Height), B (Height), C (Length shell), D (Length with cover), and E (Width). Also shows connection points labeled X (Suction), Y (Discharge), Z (Process), and orientation indicators.
Connectors Data
Connection Type | ||||
---|---|---|---|---|
Suction (X) | Discharge (Y) | Process (Z) | ||
Diameter [mm] | øi 8,11-8,29 | øi 6,11-6,29 | øi 6,11-6,29 | |
(i:inside, o:outside) [in] | øi 0,32-0,33 | øi 0,24-0,25 | øi 0,24-0,25 | |
Material | copper | copper | copper | |
Horizontal angle | ±2° | 35° | 13° | 0° |
Vertical angle | ±2° | 30° | 40° | 145° |
Position l/h/w [mm] | 119/73/59 | 117/107/66 | -88/101/71 | |
[in] | 4,7/2,9/2,3 | 4,6/4,2/2,6 | -3,5/4/2,8 | |
Straight tube l. [mm] | 14 | 14 | 14 | |
[in] | 0,5 | 0,5 | 0,5 |
Compressor Fixation
Baseplate | Large holes | Small holes | ||||||
---|---|---|---|---|---|---|---|---|
[mm] | [inch] | [mm] | [inch] | [mm] | [inch] | |||
Bl | 204 | 8.03 | Ll | 165 | 6.5 | Sl | 170 | 6.7 |
Bw | 132 | 5.2 | ||||||
ØE | Ø 9.7 | Ø 0.38 | ||||||
Lw | 101.6 | 4 | ØL | Ø 19 | Ø 0.75 | Sw | 70 | 2.76 |
ØS | Ø 16 | Ø 0.63 |
Diagram: Compressor fixation points illustration showing baseplate dimensions (Bl, Bw, Lw, Sw) and hole sizes (ØE, ØL, ØS, Sl). Includes labels for suction (SI), discharge (BI), and other points.
Diagram: Bolt joint illustration showing how the compressor base is attached using a bolt, washer, nut, sleeve, cabinet base, and rubber grommet.
Diagram: Snap-on connection illustration showing attachment via a clip, steel pin, compressor base, cabinet base, and rubber grommet.
Mounting Accessories
Accessory Type | Part Number (Single) | Part Number (Multi-pack) |
---|---|---|
Bolt joint | M6 | Ø16mm | 118-1917 | 118-1918 |
Bolt joint | ø1/4" | ø16mm | 118-1946 | |
Bolt joint | ø1/4" | ø19mm | 118-1949 | |
Snap-on | Ø7,3 | Ø16mm | 118-1947 | 118-1919 |
Application Notes
Provision for PE Grounding is located at the PE Stamp on the compressor.
Ambient/Machine Room Temperatures
Environment | Minimum | Maximum |
---|---|---|
Ambient temperature range | 10 - 43°C | 50 - 110°F |
Machine room temperature range | 10 - 48°C | 50 - 119°F |
Compressor Cooling: fan 3m/s
Operation Pressure Range
This section presents graphical data illustrating the compressor's operation pressure ranges. The graphs show condensing pressure versus evaporation pressure under continuous and transitory operation conditions.
Graph 1: Condensing Pressure vs. Evaporation Pressure
- X-axis: Evaporation Pressure [bar] (0 to 16)
- Y-axis: Condensing Pressure [bar] (50 to 170)
- Temperature scales (°C and °F) are provided below the X-axis.
- Lines indicate 'continuous operation' and 'transitory operation'.
Graph 2: Condensing Pressure vs. Evaporation Pressure (Alternative Scale)
- X-axis: Evaporation Pressure [bar] (0 to 16)
- Y-axis: Condensing Pressure [bar] (0 to 25)
- Temperature scales (°C and °F) are provided below the X-axis.
- Lines indicate 'continuous operation' and 'transitory operation'.
Diagram: Electrical accessories and wiring diagram showing components like a current relay (a5), start capacitor (c), and cover/clamp/screws assemblies (b, d).
Optimization + Standard Conditions
Performance data under various standard conditions for R290, 220V/50Hz, CSIR, fan 3m/s, VDE.
Evaporating Pressure (Saturation Temp.) | Condensing Pressure (Saturation Temp.) | Return Gas Temp. | Liquid Temp. | Cooling Capacity | COP | EER | Power Consumption | Ref. mass flow [kg/h] | |||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
[W] | [Btu/h] | [kcal/h] | [W/W] | [Btu/Wh] | [kcal/Wh] | [W] | [A] | ||||||||
[°C] -23 [°F] -10 |
54 130 |
32 90 |
32 90 |
455,6 | 1556 | 392,1 | 1,61 | 5,48 | 1,38 | 283,7 | 1,77 | 4,61 | ASHRAE LBP | ||
[°C] -25 [°F] -13 |
55 131 |
32 90 |
55 131 |
342,5 | 1170 | 294,7 | 1,25 | 4,27 | 1,08 | 273,8 | 1,74 | 4,26 | cecomaf LBP | ||
[°C] -35 [°F] -31 |
40 104 |
20 68 |
40 104 |
253,2 | 865 | 217,9 | 1,27 | 4,35 | 1,10 | 198,6 | 1,51 | 2,89 | EN12900 LBP | ||
[°C] -7 [°F] 20 |
54 130 |
35 95 |
46 115 |
791,6 | 2703 | 681,2 | 2,00 | 6,83 | 1,72 | 396,0 | 2,19 | 9,03 | ASHRAE MBP | ||
[°C] -10 [°F] 14 |
55 131 |
32 90 |
55 131 |
631,8 | 2158 | 543,8 | 1,69 | 5,76 | 1,45 | 374,9 | 2,11 | 7,99 | cecomaf MBP | ||
[°C] -10 [°F] 14 |
45 113 |
20 68 |
45 113 |
701,4 | 2395 | 603,6 | 2,05 | 7,01 | 1,77 | 341,9 | 1,98 | 8,61 | EN12900 MBP | ||
Performance Tables
Performance data for R290, 220V/50Hz, CSIR, fan 3m/s, VDE.
Cooling Capacity | COP | EER | Power Consumption | Ref. mass flow [kg/h] | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
pe [°C] | [°F] | [W] | [Btu/h] | [kcal/h] | [W/W] | [Btu/Wh] | [kcal/Wh] | [W] | [A] | |||||
cond. pressure pc= 45/113 |
-40 | -40 | 182,8 | 624 | 157,3 | 1,03 | 3,52 | 0,89 | 177,4 | 1,46 | 2,04 | |||
-35 | -31 | 243,8 | 833 | 209,8 | 1,20 | 4,09 | 1,03 | 203,4 | 1,52 | 2,73 | ||||
-25 | -13 | 397,2 | 1357 | 341,9 | 1,54 | 5,25 | 1,32 | 258,4 | 1,69 | 4,48 | ||||
-15 | 5 | 603,3 | 2060 | 519,2 | 1,92 | 6,55 | 1,65 | 314,5 | 1,88 | 6,86 | ||||
-5 | 23 | 875,1 | 2989 | 753,1 | 2,38 | 8,12 | 2,04 | 368,3 | 2,08 | 10,08 | ||||
liquid temp Tliq= 45/113 |
0 | 32 | 1039,8 | 3551 | 894,8 | 2,64 | 9,03 | 2,28 | 393,2 | 2,18 | 12,06 | |||
10 | 50 | 1434,7 | 4900 | 1234,7 | 3,28 | 11,21 | 2,83 | 437,0 | 2,36 | 16,95 | ||||
cond. pressure pc= 55/131 |
-40 | -40 | 150,2 | 513 | 129,3 | 0,81 | 2,76 | 0,70 | 185,7 | 1,48 | 1,85 | |||
-35 | -31 | 206,3 | 704 | 177,5 | 0,97 | 3,31 | 0,83 | 212,9 | 1,55 | 2,55 | ||||
-25 | -13 | 342,5 | 1170 | 294,7 | 1,25 | 4,27 | 1,08 | 273,8 | 1,74 | 4,26 | ||||
-15 | 5 | 521,9 | 1782 | 449,1 | 1,53 | 5,23 | 1,32 | 340,5 | 1,98 | 6,56 | ||||
-5 | 23 | 757,5 | 2587 | 651,9 | 1,85 | 6,32 | 1,59 | 409,5 | 2,25 | 9,65 | ||||
liquid temp Tliq= 55/131 |
0 | 32 | 900,5 | 3075 | 775,0 | 2,03 | 6,93 | 1,75 | 443,8 | 2,39 | 11,57 | |||
10 | 50 | 1245,0 | 4252 | 1071,4 | 2,44 | 8,34 | 2,10 | 509,8 | 2,67 | 16,32 |