Resistex Miks Lighting Fixture
Installation Guide
Document Version: V1.1 - 09.22
Product Overview
This document provides installation instructions and safety guidelines for the Resistex Miks lighting fixture. The Miks series offers options for adjustable orientation and low luminance applications.
Safety Notes
- Never work on the luminaire when it is live (under voltage).
- Installation must be performed by a professional installer in compliance with relevant electrical installation standards and regulations.
- Be aware of the risk of electrostatic discharges (ESD Norm). Handle components with necessary precautions.
- Please observe all indications and follow the mounting steps carefully.
Maintenance Instructions
- Do not use chemical or abrasive products to clean the fixture.
- Keep this manual for future dismantling or maintenance work. Additional information about RESISTEX luminaires can be found on the website: www.resistex-sa.com.
- RESISTEX is not responsible for any misuse of the product.
Installation Steps
The following steps detail the mounting and electrical connection process for the Resistex Miks lighting fixture.
Step 1: Prepare the Installation Hole
Cut a circular hole in the mounting surface with a diameter of Ø69 mm (+/-1 mm). Ensure the power supply to the area is switched OFF [Power Off symbol].
Visual Description: Diagram shows a circular template for cutting a hole, with dimensions Ø69 (+/-1mm).
Step 2: Insert the Fixture
Insert the recessed light fixture into the prepared ceiling cutout. The spring clips on the fixture should be extended to fit into the opening.
Visual Description: Diagram shows a recessed light fixture with spring clips, being inserted into a ceiling cutout. An upward arrow indicates insertion.
Step 3: Secure the Fixture
Rotate the fixture clockwise [circular-arrow] to engage its spring clips, securing it firmly in place within the ceiling cutout.
Visual Description: Diagram shows the fixture being rotated clockwise to secure it.
Step 4: Connect Power Cable
Connect the power cable to the fixture's integrated connector. This typically involves pushing the wires into a push-in terminal block.
Visual Description: Close-up view of a wire connector showing wires being inserted into a push-in terminal. Arrows indicate insertion and locking.
Step 5: Open Terminal Block
Open the terminal block lever [arrow-up] to prepare for wire insertion.
Visual Description: Diagram shows a terminal block with an open lever.
Step 6: Insert Wires
Insert the power supply wires into the terminal block. Connect the Line (L) wire and the Neutral (N) wire to their respective terminals.
Visual Description: Diagram shows wires being inserted into the terminal block, with 'L' and 'N' labels visible.
Step 7: Close Terminal Block
Close the terminal block lever [arrow-down] to securely fasten the inserted wires.
Visual Description: Diagram shows the terminal block lever being closed.
Step 8: Final Insertion
Gently compress the fixture and its spring clips, then insert it fully into the ceiling cutout. The spring clips will expand to hold the fixture in place.
Visual Description: Diagram shows the fixture being compressed and inserted into the ceiling, with spring clips ready to engage.
Step 9: Verify Wiring
Ensure electrical connections are correct. A correct connection is shown with a green checkmark [✔️], where wires are properly inserted into the terminal block. An incorrect connection is shown with a red cross [❌].
Visual Description: Diagram illustrates correct (✔️) and incorrect (❌) wiring connections to the terminal block.
Step 10: Complete Installation
The fixture is now installed in the ceiling. The diagram indicates the light is functional (ON).
Visual Description: Diagram shows the final installed fixture in a ceiling, with an indicator suggesting it is ON.
Certifications and Compliance
The Resistex Miks fixture complies with the following standards:
- ROHS compliant
- Class II protection
- IP65 rating (dust and water jet protected)
- IK07 rating (impact resistant)
- 82 (specific metric, e.g., energy efficiency or CRI)
- 5 Year Warranty
- CE marked