Step 1: Prepare the Installation Hole

Cut a circular hole in the mounting surface with a diameter of Ø69 mm (+/-1 mm). Ensure the power supply to the area is switched OFF [Power Off symbol].

Visual Description: Diagram shows a circular template for cutting a hole, with dimensions Ø69 (+/-1mm).

Step 2: Insert the Fixture

Insert the recessed light fixture into the prepared ceiling cutout. The spring clips on the fixture should be extended to fit into the opening.

Visual Description: Diagram shows a recessed light fixture with spring clips, being inserted into a ceiling cutout. An upward arrow indicates insertion.

Step 3: Secure the Fixture

Rotate the fixture clockwise [circular-arrow] to engage its spring clips, securing it firmly in place within the ceiling cutout.

Visual Description: Diagram shows the fixture being rotated clockwise to secure it.

Step 4: Connect Power Cable

Connect the power cable to the fixture's integrated connector. This typically involves pushing the wires into a push-in terminal block.

Visual Description: Close-up view of a wire connector showing wires being inserted into a push-in terminal. Arrows indicate insertion and locking.

Step 5: Open Terminal Block

Open the terminal block lever [arrow-up] to prepare for wire insertion.

Visual Description: Diagram shows a terminal block with an open lever.

Step 6: Insert Wires

Insert the power supply wires into the terminal block. Connect the Line (L) wire and the Neutral (N) wire to their respective terminals.

Visual Description: Diagram shows wires being inserted into the terminal block, with 'L' and 'N' labels visible.

Step 7: Close Terminal Block

Close the terminal block lever [arrow-down] to securely fasten the inserted wires.

Visual Description: Diagram shows the terminal block lever being closed.

Step 8: Final Insertion

Gently compress the fixture and its spring clips, then insert it fully into the ceiling cutout. The spring clips will expand to hold the fixture in place.

Visual Description: Diagram shows the fixture being compressed and inserted into the ceiling, with spring clips ready to engage.

Step 9: Verify Wiring

Ensure electrical connections are correct. A correct connection is shown with a green checkmark [✔️], where wires are properly inserted into the terminal block. An incorrect connection is shown with a red cross [❌].

Visual Description: Diagram illustrates correct (✔️) and incorrect (❌) wiring connections to the terminal block.

Step 10: Complete Installation

The fixture is now installed in the ceiling. The diagram indicates the light is functional (ON).

Visual Description: Diagram shows the final installed fixture in a ceiling, with an indicator suggesting it is ON.

Certifications and Compliance

The Resistex Miks fixture complies with the following standards:

Models: 1043lm CCT B.LUM RD-RD BLANC, 963252, Miks Ceiling Light, Miks, Ceiling Light, Light

File Info : application/pdf, 2 Pages, 676.99KB

PDF preview unavailable. Download the PDF instead.

963252 NOT1

References

GPL Ghostscript 9.53.3

Related Documents

Preview Resistex Miks Installation Guide
Comprehensive installation instructions for the Resistex Miks lighting fixture, detailing safety precautions, mounting procedures, wiring, and maintenance. Includes product specifications and company information.
Preview Resistex MIKS 926lm CCT B.LUM LED Downlight - Technical Specifications
Detailed technical specifications for the Resistex MIKS 926lm CCT B.LUM RD/RD BLANC REFLECTEUR OR recessed LED downlight, including reference, IP rating, dimensions, luminous flux, power consumption, and warranty.
Preview EU Declaration of Conformity: Resistex 963252 MIKS Lighting Fixture
Official EU Declaration of Conformity for the Resistex 963252 MIKS Downlight & Spot lighting fixture. This document confirms compliance with key European directives including Low Voltage, EMC, RoHS, and Eco-design, along with relevant harmonized standards.
Preview Resistex Miks LED Downlight Installation Guide
Comprehensive installation instructions for the Resistex Miks LED downlight, detailing safety precautions, wiring, and mounting steps for professional installation.
Preview Déclaration UE de Conformité : Résistex 963255 MIKS Éclairage
Déclaration de conformité de l'Union Européenne pour le luminaire Résistex 963255 MIKS, conforme aux directives de sécurité, compatibilité électromagnétique, restriction de substances dangereuses et éco-conception.
Preview Luminaire LED Encastré Resistex MIKS 1043lm CCT B.LUM - Spécifications Techniques
Spécifications techniques détaillées pour le luminaire LED encastré étanche Resistex MIKS 1043lm CCT B.LUM RD/RD Noir Réflecteur Blanc. Ce luminaire conforme RT2012/RE2020 offre 1043lm, 11.3W, IP65, et une garantie de 5 ans.
Preview Resistex MIKS 1027lm CCT B.LUM Recessed Downlight - Technical Specifications
Detailed technical specifications for the Resistex MIKS 1027lm CCT B.LUM recessed downlight, including its features, dimensions, performance metrics, and compliance information.
Preview Resistex Miks LED Downlight Installation Guide
Comprehensive installation, safety, and maintenance instructions for the Resistex Miks LED downlight, featuring adjustable and low luminance options. Includes wiring diagrams and company details.