Installation Guide for AMP Lighting models including: AFL-4031-B-BZ Paramount Pro LED Flood Light, AFL-4031-B-BZ, Paramount Pro LED Flood Light, Pro LED Flood Light, LED Flood Light, Flood Light, Light
RGBCW ParamountPro LED Flood Light | AMP Lighting
File Info : application/pdf, 14 Pages, 1.40MB
DocumentDocumentINSTALLATION & MAINTENANCE GUIDE AMP® LOW VOLTAGE LANDSCAPE LIGHTING AMP® RGBCW ParamountPro LED Flood Light ITEM: AFL-4031-B-BZ 1-813-978-3900 · Mon-Fri 9am-6pm (EST) - 1 - INSTALLATION & MAINTENANCE GUIDE AMP® RGBCW ParamountPro LED Flood Light - AFL-4031-B-BZ ! IMPORTANT SAFETY INSTRUCTIONS: READ BEFORE INSTALLATION This luminaire is intended for installation in accordance with local codes and the National Electric Code (NEC). Failure to adhere to these codes and instructions may result in serious injury, property damage and void the warranty. These instructions do not intend to cover all variations in installation, operation maintenance or mounting situations. 1.Make sure that the power is turned OFF before installing or servicing this luminaire. 2.WARNING: risk of electrical shock. Install all luminaires 10 feet (3.05M) or more from pool, spa or fountain. 3.This luminaire is intended to be used only with a power supply (transformer) rated maximum of 300 watts (25 AMPS) at 15 volts. 4.Wiring connections must be made with UL listed wire connectors that are suitable for outdoor use. 5.Position the low voltage wire and wire connector so that it is located within 6 inches (15.2 cm) from a building structure, a luminaire or fitting. 6.The main low voltage cable is intended for shallow burial - less than 6 inches (152 mm). ! IMPORTANT SAFETY INSTRUCTIONS INSTRUCTIONS PERTAINING TO A RISK OF FIRE, OR INJURY TO PERSONS LIGHTED FIXTURE IS HOT! WARNING TO REDUCE THE RISK OF FIRE OR INJURY TO PERSONS. 1.Turn off/unplug and allow to cool before replacing lamp. 2.Fixture gets HOT quickly! Contact switch/plug only when turning on. 3.Do not touch the hot lens, guard or enclosure. 4.Keep fixture away from materials that may burn. 5.Do not operate the luminaire fitting with a missing or damaged shield. SAVE THESE INSTRUCTIONS 813.978.3900 · customersupport@amplighting.com · www.amplighting.com 2 PACKAGE CONTENTS A. (1) Fixture Body B. (1) Allen Wrench PRODUCT DIMENSIONS 3.24" C. (1) Frosted Lens D. (1) Diffused Lens 2.68" 2.43" 1.33" 1 INSTALL STAKE Board Stake Ground Soil Determine the desired location for mounting the stake. Hammer the stake into the ground until flange of stake is flush to grade. To avoid damage to the stake, place a board on top of the stake while hammering. Note: If the ground is hard and the stake is difficult to install, make a crosscut in the ground using a flat shovel. 3 INSTALLATION & MAINTENANCE GUIDE AMP® RGBCW ParamountPro LED Flood Light - AFL-4031-B-BZ 2 INSTALL FIXTURE TO STAKE Supply Wires Fixture Body Ground Pass supply wires through the center hole of the stake and thread the stem onto the stake. Hand tighten until snug. Clear away an area in the ground and lay supply wires into wireway slots. Stake Soil 3 WIRE CONNECTION Fixture Wires Wire Connectors Main Supply Cable Strip two leads from fixture wires. Using two UL listed wire connectors (not provided), connect leads from fixture wires to main supply cable leads. 813.978.3900 · customersupport@amplighting.com · www.amplighting.com 4 4 ADJUST DIRECTION Luminaire Screw By using the Allen wrench, unlock the screw at the joint to adjust the luminaire directions. Tighten the screw when the desired direction is Allen Wrench achieved. HOW TO REPLACE LENS There are three lenses provided with the product. A clear lens has been installed on the product as a default lens, which can be replaced with a frosted lens or diffused lens by using the following steps. Frosted Lens Diffused Lens 813.978.3900 · customersupport@amplighting.com · www.amplighting.com 5 INSTALLATION & MAINTENANCE GUIDE AMP® RGBCW ParamountPro LED Flood Light - AFL-4031-B-BZ 5 REMOVE GLARE GUARD AND GASKET WITH LENS Fixture Body Screw Glare Guard Gasket with Lens Unlock the screws to remove the glare guard and gasket with lens from the fixture body. 6 REMOVE CLEAR LENS Gasket Remove the clear lens out of the gasket. Clear Lens 813.978.3900 · customersupport@amplighting.com · www.amplighting.com 6 7 INSTALL FROSTED OR DIFFUSED LENS Gasket Insert the desired frosted lens or diffused lens into the gasket. Frosted Lens or Diffused Lens 8 INSTALL FROSTED OR DIFFUSED LENS Fixture Body Screw Glare Guard Gasket with New Lens Place the gasket with new lens, the glare guard back onto the fixture body and secure with previously removed screws. Hand tighten until snug. 813.978.3900 · customersupport@amplighting.com · www.amplighting.com 7 INSTALLATION & MAINTENANCE GUIDE AMP® RGBCW ParamountPro LED Flood Light - AFL-4031-B-BZ REMOTE CONTROL INSTRUCTIONS 1 ALL ON ALL OFF 2 No. 3 4 1 5 6 2 7 W C 8 3 CCT 9 123 10 4 456 ZONE 5,6 Button Name ALL ON ALL OFF Indicator Function Description Turns on all lights which are controlled by this remote that are within range. Turns off all lights which are controlled by this remote that are within range. Illuminates red when any button is pressed to indicate signal transmission. RGB color wheel. Touch the desired color to change the light fixture within the selected zone and within range to that color. Decrease or increase the light fixture brightness on the selected zone and within range by pressing the corresponding button. No. Button Name Function Description 7 W Adjusts the light to a warmer color temperature (CCT). Short press for increments, long press for continuous adjustment. 8 C Adjusts the light to a cooler color temperature (CCT). Short press for increments, long press for continuous adjustment. 9 CCT Color temperature (CCT) selector. Toggles through 2200K-2700K3000K-4000K CCT when pressing 10 ZONE 1,2,3,4,5,6 Short press to select desired zone. Long press to turn zone on or off. 8 1 INSTALL AAA BATTERIES Back of Remote Controller Battery Compartment Open the battery cover, install two AAA 1.5V batteries into the battery compartment. Pay attention to the "+"/"-" polarities of the battery when installing. Always reinstall the battery cover after installing AAA 1.5V batteries. + - AAA Battery - + (Sold Separately) Battery Cover 2 PAIRING THE REMOTE ALL ON ALL OFF W C CCT 123 456 ZONE All products default to a factory setting. The lights must be paired by the remote controller before using them. ZONE 1. Install light(s). 2. Power the light(s) on. The light(s) will blink between warm and cool light for 30 seconds indicating pairing mode. 3. While the light(s) are in pairing mode, press the desired zone number on the remote once to pair the light fixture(s) with that zone. Cool white light (4000K) will flash three times indicating that the fixture is paired successfully with the zone. The light(s) will turn to warm white light (2200K). 9 INSTALLATION & MAINTENANCE GUIDE AMP® RGBCW ParamountPro LED Flood Light - AFL-4031-B-BZ 2 PAIRING THE REMOTE (CONTINUED) 1. Using the same process you can pair additional fixtures to the same or different zones. Note: 1. Please ensure light(s) are within range of the remote controller. 2. If zone pairing fails, power the light(s) OFF and ON, then repeat the above steps. 3. If pairing operation is not completed within 30 seconds, the lights will return to their default static cool white CCT (4000K). Once in this state, whenever the light(s) are powered OFF and back ON, the light(s) will re-initiate pairing mode for 30 seconds. This process will continue until pairing is successful. 4. The RF bulb(s) or fixture(s) can be paired with a maximum of 4 remote controllers. Power the light(s) OFF and ON and within 30 seconds the bulbs and fixtures can be paired with another remote controller by pressing the desired zone number. The fixture will flash cool white light (4000K) once after successful pairing. The bulb(s) or fixture(s) can be controlled by any of the paired remote controllers. 5. If more than four remote controllers are paired to the lights successfully, the first remote controller will be unpaired automatically. Only the last four remote controllers are functional. 10 3 ADJUST BRIGHTNESS ALL ON ALL OFF Brightness Decrease W C CCT 123 1. Select the desired lights by pressing the zone to which they have been assigned. 2. Press the brightness Brightness Increase increase button to increase the light brightness, or press the brightness decrease button to decrease the light ZONE brightness. 456 ZONE 4 ADJUST COLOR TEMPERATURE Note: 1. Press the or button once and the brightness will adjust one level. 2. Long press the or button, and the brightness will gradually increase or decrease until the button is released. Warm Light Button ALL ON ALL OFF W C CCT 123 456 ZONE 1. Select the lights by pressing the zone they are in. 2. Press the warm light button or cool light button Cool Light Button to the desired color temperature. ZONE Note: 1. Press the warm light button or cool light button once, the color temperature will adjust to the next level. 2. Long press the warm light button or cool light button, the color temperature will gradually increase or decrease until the button is released. 11 INSTALLATION & MAINTENANCE GUIDE AMP® RGBCW ParamountPro LED Flood Light - AFL-4031-B-BZ 5 QUICK COLOR TEMPERATURE ADJUSTMENT ALL ON ALL OFF W C CCT 123 456 ZONE CCT Button ZONE The preset color temperatures of the CCT button are 2200K, 27000K, 3000K and 4000K. 1. Select the lights by pressing the zone they are in. 2. Press the CCT button to adjust the lights through 2200K-2700K-3000K-4000K color temperatures. 6 ADJUST COLOR ALL ON ALL OFF Warm Light Button W C CCT 123 456 ZONE Use the RGB Palette wheel to select colored light modes RGB and "W", "C", or "CCT" buttons Palette to select white light modes. 1. For white light, press Cool Light Button the warm light button or cool light button to adjust the white light color temperature. 2. For color light, touch the RGB palette wheel to adjust the light color. 12 7 CONTROL BY GROUP All ON ALL ON ALL OFF 7 W C CCT 123 456 ZONE ZONE (Group) 1. To control lights by group, Select the lights by pressing the zone they are in. And then press respective function buttons to adjust the lights. 8 UNPAIR LIGHTS All ON ALL ON ALL OFF W C CCT 123 456 ZONE ZONE If you need to re-pair the light(s) that have already been paired to a different zone, they must be unpaired first. 1. To unpair lights by group, turn off the light(s) that are required to be unpaired and then back on. Select the light(s) by pressing the zone they are in. Press the corresponding zone button 6 times. 2. To unpair all lights, turn off all lights and then turn on all lights. Press the all "ON" button 6 times. 3. After pressing six times, the corresponding lights will flash three times and then turn off, indicating that unpairing is complete. Now the lights will be restored to the factory settings. Note: 1. When the lights are ready for unpairing, you must only press zone button 1 to 6 in the zone area or "ON" button. Otherwise, unpairing will fail. 2. If unpairing fails, the process needs to be re-initiated. 13 1-813-978-3700 · Mon-Fri 9am-6pm (EST) Specifications and product details subject to change without notice. © Copyright 2024, AMP® Lighting, Lutz FL USA 33549 · All rights reserved. customersupport@amplighting.com · amplighting.com 16