TacoGenie® Hot Water Circulator

SAVE ENERGY • SAVE WATER • SAVE MONEY

Product Overview

The TacoGenie® Hot Water Circulator provides instant hot water while saving up to 12,000 gallons of water per year. This small, quiet pump attaches to the hot and cold water lines in the cabinet under the most remote kitchen or bath fixture in the home. The TacoGenie circulates hot water from the water heater and returns the cooled water back through the cold water line. When hot water arrives at the faucet, TacoGenie automatically shuts off to prevent excess hot water in the cold water line.

Certifications: cULus Listed, NSF Certified to NSF/ANSI/CAN 61 & 372, California Title 24 Compliant.

Catalog Information: Taco Catalog # 100-15, Supersedes: 06/28/19, Effective Date: 12/12/24, Printed in USA.

Features

Hot water when YOU want it.

Settings & Applications

Standard Piping

Typical plumbing of hot and cold water lines that lead from the source to each point of use. The TacoGenie circulates hot water from the water heater, and returns the cooled water back through the cold water line. When hot water arrives at the faucet, the TacoGenie heat sensor and control board shut off the pump, conserving water and energy.

Diagram Description (Standard Piping): Illustrates a system with City Water Supply connected to a Tank Type Water Heater or Tankless Water Heater. Hot water flows from the heater to a faucet. The TacoGenie unit is installed on the hot water line near the faucet. A sensor at the faucet detects hot water and signals the TacoGenie to shut off. The system also shows optional remote activation (starter button, motion sensor) connected via wired connections or a remote receiver.

Recirculation Loop

A dedicated return line that recirculates hot water to its source from the point of use, conserving water which would otherwise go down the drain.

Diagram Description (Recirculation Loop): Shows a system where a dedicated return line runs from the faucet back to the water heater, with the TacoGenie unit installed in this loop. Hot water is circulated continuously, and when the faucet is opened, the sensor at the faucet detects hot water and signals the TacoGenie to shut off, ensuring hot water is available quickly and saving water.

Submittal Data Information

Standard Piping: Tank Type Water Heater

Size of Home Total length of Pipe (ft) Max. Model
Small 50 006-CT-USK
Medium 100 008-CT-USK
Large/Commercial 200 0011-CF-USK

Standard Piping: Tankless Water Heater

Size of Home Total length of Pipe (ft) Max. Model
Small/Medium 60 008-CT-USK
Large/Commercial 150 0011-CF-USK

Recirculation Piping: Tank Type Water Heater

Size of Home Total length of Pipe (ft) Max. Model
Small 100 006-CT
Medium 200 008-CT
Large/Commercial 400 0011-CF

Recirculation Piping: Tankless Water Heater

Size of Home Total length of Pipe (ft) Max. Model
Small/Medium 100 008-CT
Large/Commercial 200 0011-CF

Model Key: C = TacoGenie, T = Threaded, F = Flanged, USK = Under Sink Kit.

TacoGenie System Accessories

Performance Field Information - 60 Hz

This section provides performance data for TacoGenie System Models based on flow rate and total head. The graph shows curves for models 006-CT-USK, 008-CT-USK, and 0011-CF-USK, illustrating the relationship between flow rate (in GPM and M³/H) and total head (in feet and meters).

Image Description (Standard TacoGenie with USK* option): Depicts the TacoGenie unit configured with the Under Sink Kit (USK), which is noted as being included with the USK.

Image Description (Accessories): Shows the RF Wireless Starter Kit (Model 554-7), Transmitter Only (Model 554-8), and Motion Sensor (Model 554-4) accessories.

PDF preview unavailable. Download the PDF instead.

TacoGenie-Hot-Water-Circulator Catalog 100-15 Adobe PDF Library 17.0

Related Documents

Preview Taco HLS-2 Hot-Link System for Domestic Hot Water Recirculation - Instruction Sheet
Instruction sheet for the Taco HLS-2 Hot-Link System, a domestic hot water recirculation system designed to provide instant hot water and save water. Includes installation guide, timer settings, troubleshooting, and warranty information.
Preview Taco Hot-LinkPlus-e ECM Hot Water Recirculation System Instruction Sheet
Comprehensive guide for installing and operating the Taco Hot-LinkPlus-e ECM High-Efficiency Hot Water Recirculation System with SmartPlug control, detailing features, installation steps, and troubleshooting tips.
Preview Taco 007e ECM High-Efficiency Circulator Pump: Features, Specifications, and Applications
Comprehensive guide to the Taco 007e ECM High-Efficiency Circulator pump, detailing its advanced features, technical specifications, materials, installation applications for hydronic and potable water systems, and performance characteristics.
Preview Taco 1600 Series In-Line Pumps: Reliable & Efficient Water Circulation
Discover the Taco 1600 Series In-Line Pumps, engineered for ultimate reliability, ease of installation, and quiet performance in heating, air conditioning, pressure boosting, and water supply applications. View detailed features, specifications, and dimensions.
Preview Taco LeakBreaker Water Heater Shut-Off: Flood Protection with eLink® Wi-Fi Alerts
The Taco LeakBreaker is an automatic water heater shut-off device designed to prevent flood damage from water heater failures. It features resettable protection, a multi-color LED status light, an audible alarm, and optional eLink® Wi-Fi connectivity for real-time alerts. NSF certified for safety.
Preview Taco SR501-4 Switching Relay Instruction Sheet and Wiring Guide
Detailed instruction sheet for the Taco SR501-4 Switching Relay, covering features, operation, wiring diagrams, specifications, troubleshooting, and warranty information for HVAC professionals.
Preview TACO Zone Control Product Information and Wiring Guide
Comprehensive overview of TACO zone control products, including switching relays, zone valve controls, and add-on power controls, with detailed product information, specifications, and wiring diagrams for HVAC systems.
Preview Taco SR506 Switching Relay Instruction Sheet
Instruction sheet for the Taco SR506 Switching Relay, detailing wiring diagrams, operation, priority settings, jumper placement, power input, external diagnostics, and specifications for both Cold Start Boiler and Tankless Coil Boiler applications. Includes features and manufacturer information.