Event Lighting F200VW Variable White Fresnel with Manual Zoom

User Manual

Version 3.1 (08.07.2025)

Safety Instructions

WARNING

CAUTION

Power Input & Power Linking

This device has an auto-switching power supply working with input voltage range of 100~240 VAC, 50/60 Hz. Link up to the maximum 8A. DO NOT exceed this number.

Product Installation

This device can be mounted in many orientations, provided each individual device is secured by the use of the correct mounting bracket. Use a safety chain when mounting this device overhead.

Fuse Replacement

If the fine-wire fuse of the device blows, only replace the fuse with a fuse of the same type and rating. Before replacing the fuse, unplug the mains lead.

Procedure:

  1. Unscrew the fuse holder on the rear panel with a fitting screwdriver from the housing (anticlockwise).
  2. Remove the old fuse from the fuse holder.
  3. Install the new fuse in the fuse holder.
  4. Replace the fuse holder in the housing and fix it.

Diagrams

Lux Chart

Lux @20°

Distance From Source1m / 3'3"2m / 6'7"3m / 9'10"4m / 13'2"
2600K13,0653,3001,530844
6600K17,9504,6702,2161,185
Full30,1707,8163,5501,993
DiameterØ0.36m / 1'2"Ø0.72m / 2'4"Ø1.08m / 3'7"Ø1.44m / 4'9"

Lux @53°

Distance From Source1m / 3'3"2m / 6'7"3m / 9'10"4m / 13'2"
2600K3,7701,010445255
6600K5,2651,395612355
Full8,8652,3451,025596
DiameterØ0.99m / 3'3"Ø1.98m / 6'6"Ø2.96m / 9'9"Ø3.95m / 12'12"

Visual representation of light spread: A diagram shows a light source emitting a beam that widens with distance. Four vertical lines indicate distances of 1m, 2m, 3m, and 4m, with elliptical shapes representing the light coverage at each distance, showing how the beam diameter increases.

Dimensions

The following diagrams illustrate the physical dimensions of the F200VW fixture:

Control Board Operation

The F200VW features a 4-button LCD control panel for operation.

Control Board Functions

DisplayOptions / ValuesFunction
DMX Add<001> - <508>To set DMX address
DMX Cha<01>, <1U><02>, <05>,<07><User>To set DMX channel modes
DMXLoss<Hold><Blackout><Manual>Select mode when DMX loss
UserDMXCH:<01> EndEdit a user DMX mode
ManualPreset <StrawW> <WarmW> <White> <CoolW> <Steel>To select colour from 5 preset colour temperature modes
Finetune <Straw> <Straw+> <Stra++> <--Warm> <-WarmW> <WarmW> <WarmW+> <Warm++> <--Whit><-White> <White> <White+> <Whit++> <--Cool> <-CoolW> <CoolW> <CoolW+> <Cool++> <--Stee> <-Steel> <Steel>To select colour from 21 fine tune colour temperature modes
Dimmer <000> - <100>To set dimming intensity
Mas/Sla< Sla> / <Mas>To set Master/Slave modes
Wireless<ON><OFF> <EL Mode> <W-DMX_R> <W-DMX_T>You need to install WDMX module inside the fixture first and then receive the DMX signal from the transmitter attached to the console by setting this on
Reset<N>/ <Y>To reset factory default setting
Update<N>/ <Y> <START>Select to update firmware Use this fixture to update another fixture's software

DMX Addressing

After selecting the "DMX Add", press "Enter". Use "Up" and "Down" buttons to select the desired DMX address, then press "Enter" to save the new setting.

DMX Modes

After selecting the "DMX Cha", press "Enter". Use "Up" and "Down" buttons to select the desired DMX mode, then press "Enter" to save the new setting.

DMX Loss

This feature allows users to set the behavior when DMX signal is lost.

User DMX

This function allows users to define custom DMX modes. Users can select channels and assign functions. For example, selecting 'User DMX' allows channel selection and rearrangement. Setting an 'End' channel stops the sequence. If 10 channels are desired, the 11th channel acts as 'End', creating a 10-channel user mode. This mode is then selected under DMX Channel mode as 'User'.

Manual Mode

After entering "Manual" mode, use the "Up" and "Down" buttons to select colours from preset groups and fine-tune groups. Set intensity from 000 to 255, then press "Enter" to save.

Master/Slave

Set the master fixture to one of the standalone operating modes. To set a slave fixture, enter "Mas/Sla" mode, set it to "Slave", and press "Enter" to save the setting.

Firmware Update

Use fixture A to update fixture B's firmware:

Note: Ensure fixture A and B are of the same type to avoid damage. Only fixtures A and B should be in the DMX chain during firmware updates.

DMX Chart

The following tables detail the DMX channel assignments for different modes:

1 Channel Mode

ChannelValueFunction
1000 - 255Dimmer & Colour temperature

1U Channels Mode

ChannelValueFunction
1U000 - 255Dimmer (dim the preset color selected in Menu)

2 Channels Mode

ChannelValueFunction
1000 - 255Dimmer 0% ~ 100%
2000 - 255Warm white to cool white

5 Channels Mode

ChannelValueFunction
1000-255Master dimmer coarse: 0% ~ 100%
2000 - 255Master dimmer fine: 0% ~ 100%
3000 - 255Warm white to cool white
4000-015No function(Shutter on)
016-119Strobe slow to fast (1-25Hz)
120 - 127Shutter on
128-183Strobe random slow to fast
184-191Shutter on
192 - 247Strobe audio sensitivity low to high
248-255Shutter on
5000-050Standard
6051-101Stage
102 - 152TV
153-203Architect
204-255Theater

7 Channels Mode

ChannelValueFunction
1000 - 255Master dimmer coarse: 0% ~ 100%
2000-255Master dimmer fine: 0% ~ 100%
3000-255Warm White
4000-255Cool White
5000-015No function(Shutter on)
016-119Strobe slow to fast (1-25Hz)
120-127Shutter on
128-183Strobe random slow to fast
184-191Shutter on
192 - 247Strobe audio sensitivity low to high
248 - 255Shutter on
6000-009No function
7010-255Preset Colours (Warm->Cold)
000-050Standard
8051-101Stage
102-152TV
153-203Architect
204-255Theater

Technical Specifications

Power

Photometrics

Effects

Control

Housing

Warranty

Details regarding the product warranty are provided.

Models: ZEVF200VW Variable White Fresnel with Zoom, ZEVF200VW, Variable White Fresnel with Zoom, White Fresnel with Zoom, Fresnel with Zoom

PDF preview unavailable. Download the PDF instead.

ZEVF200VW 4 Acrobat Distiller 10.0.0 (Windows)

Related Documents

Preview F200VW [-WH] Variable White Fresnel - Event Lighting Product Specifications
Comprehensive technical specifications for the EVENT LIGHTING F200VW [-WH] Variable White Fresnel, a 100W COB LED lighting fixture. Details include photometrics, effects, control options, power requirements, housing specifications, and dimensional data.
Preview Event Lighting F2X100VWL 100W LED Fresnel with Zoom User Manual
User manual for the Event Lighting F2X100VWL, a 100W LED Fresnel with Zoom. Provides detailed information on installation, operation, DMX control, menu map, DMX protocol, fixture cleaning, fuse replacement, troubleshooting, and technical specifications.
Preview OPERAC100FCF 100W RGBW LED Compact Fresnel Lighting Fixture Specifications
Detailed technical specifications, photometric data, and feature overview for the Event Lighting OPERAC100FCF, a 100W COB RGBW LED compact Fresnel spotlight with manual zoom, DMX/RDM control, and a versatile feature set for stage and event lighting.
Preview BAR24X4FXL User Manual - Event Lighting
Comprehensive user manual for the Event Lighting BAR24X4FXL lighting fixture, covering operation, DMX modes, settings, maintenance, and safety instructions.
Preview Event Lighting TDM and DM Laser User Manual - Operation, Safety, and Specifications
Comprehensive user manual for Event Lighting's TDM and DM series laser light fixtures. Includes detailed safety instructions, product installation guide, control board and DMX operation, IR remote control functions, laser emission data, and technical specifications for models like DM450B, DM100G, DM400RGB, DM200RGY, DM300RBP, and TDM-RGB400.
Preview Event Lighting LM150B 150W LED Beam Moving Head User Manual
Comprehensive user manual for the Event Lighting LM150B, a 150W LED Beam Moving Head. Covers safety instructions, installation, operation, DMX charts, technical specifications, and more.
Preview Event Lighting HAVOCH600F User Manual
Comprehensive user manual for the Event Lighting HAVOCH600F, a 600W LED Moving Head Hybrid with Framing. Includes safety warnings, product introduction, device description, installation guide, color and gobo details, DMX protocol information, and technical specifications.
Preview Event Lighting PAR19X12L User Manual - 19x 12W LED RGBWAU Parcan with IR Remote
Comprehensive user manual for the Event Lighting PAR19X12L, detailing its features, safety instructions, installation, operation via control board and IR remote, DMX charts, and technical specifications. This guide covers the 19x 12W LED RGBWAU Parcan with IR Remote.