DM200RGY – Event Lighting
1 TDM and DM Laser USER MANUAL For safety, please read this user manual carefully before initial use. Event Lighting reserves the right to revise the manual at any time. Information and specifications within this manual are subject to change without notice. Event Lighting assumes no liability or responsibility for any errors or omissions. Please consult Event Lighting for any clarification or information regarding this item. www.event-lighting.com.au V1.0 2 CONTENTS Safety Instructions Product Installation Control Board Operation - Standalone Mode - DMX Modes DMX Values IR Remote control Warranty Laser Emission Data Specifications 3 Safety Instructions WARNING · Do not open this device, there is no user-serviceable parts inside. Risk of electric shock. · Do not look at the light source when the device is on. · CAUTION: This unit's housing may be hot during and after operation. · Install this device in a location with adequate ventilation, at least 20 inch (50 cm) from adjacent surfaces. · Do not leave any flammable material within 50 cm of this unit while operating or connected to power. · Use a safety chain when mounting this device overhead. · Do not operate this device outdoors or in any location where dust, excessive heat, water, or humidity may affect it. · Do not operate this device if the housing, lenses, or cables appear damaged. · Do not connect this device to a dimmer or rheostat. · ONLY connect this device to a grounded and protected circuit. · ONLY use the hanging bracket to carry this device. · In case of a serious operating problem, stop using immediately. · The maximum ambient temperature is 104° F (40° C). Do not operate this device at higher temperatures. · Do not point this laser toward people or crowds. · Do not point this laser toward any area where you or the operator do not know where the beams are being directed. · Use aperture cover whenever not in use. · Use the key to lock the laser to avoid unauthorised use. · Avoid direct eye contact with laser light. Never intentionally expose your eyes or others to direct laser light. · This laser product can potentially cause instant eye injury or blindness if laser light directly strikes the eyes. Power Input This device has an auto-switching power supply work with input voltage range of 100~240 VAC, 50/60 Hz. Product Installation This device can be mounted in many orientations provided each individual device is secured by the use of correct mounting bracket. This device should be directed above the heads of people and do not direct it toward the line of sight of people Refer to the diagram below Use a safety chain when mounting this device overhead. 4 CONTROL BOARD OPERATION Press "MODE " button, you can select "Auto ", " Sound ", " d*** ", " SLAV ", or" tESt ", one of five kinds of mode. In the"d***"work modePress"UP"or"DOWN"to set DMX address. Press"ENTER"to save the current work mode or DMX address. MODE UP DOWN ENTER WORK MODE DESCRIPTION: R/G/B MODEL Display Work Mode Description Auto Soud d*** SLAV tESt Auto Run Mode Sound Active Mode DMX-512 Control Mode Slave Mode Test Mode Auto Run Mode Sound Active Mode Press"UP or "DOWN" to Set the DMX address Slave Mode Press"UP or "DOWN" to Select the single pattern RGY MODEL Display Auto Soud d*** SLAV tESt r/g/y/rgy Work Mode Description Auto Run Mode Sound Active Mode DMX-512 Control Mode Slave Mode Test Mode Set Color Mode Auto Run Mode Sound Active Mode Press"UP or "DOWN" to Set the DMX address Slave Mode Press"UP or "DOWN" to Select the single pattern Press"UP or "DOWN" to Select the laser color 5 RBP MODEL Display Auto Soud d*** SLAV tESt r/b/p/rbp Work Mode Description Auto Run Mode Sound Active Mode DMX-512 Control Mode Slave Mode Test Mode Set Color Mode Auto Run Mode Sound Active Mode Press"UP or "DOWN" to Set the DMX address Slave Mode Press"UP or "DOWN" to Select the single pattern Press"UP or "DOWN" to Select the laser color GBC MODEL Display Auto Soud d*** SLAV tESt g/b/c/gbc Work Mode Description Auto Run Mode Sound Active Mode DMX-512 Control Mode Slave Mode Test Mode Set Color Mode Auto Run Mode Sound Active Mode Press"UP or "DOWN" to Set the DMX address Slave Mode Press"UP or "DOWN" to Select the single pattern Press"UP or "DOWN" to Select the laser color RGB MODEL Display Auto Soud d*** SLAV tESt r/g/b/y/p/c/rgb Work Mode Description Auto Run Mode Sound Active Mode DMX-512 Control Mode Slave Mode Test Mode Set Color Mode Auto Run Mode Sound Active Mode Press"UP or "DOWN" to Set the DMX address Slave Mode Press"UP or "DOWN" to Select the single pattern Press"UP or "DOWN" to Select the laser color DMX CHANNELS DESCRIPTION: CH1 Work Mode Selection CH2 CH3 Pattern Selection Manual Mode Zoom Manual Mode CH4 X-axis rotation Manual Mode CH5 Y-axis rotation Manual Mode CH6 Z-axis rotation Manual Mode CH7 Horizontal Movement Manual Mode CH8 Vertically MovementManual Mode (R/G/B model) (RGY model) Color Select Manual Mode CH9 (RBP model) Color Select Manual Mode (GBC model) Color Select Manual Mode (RGB model) Color Select Manual Mode 6 0-063 64-127 128-191 192-255 0-255 0-127 128-255 0-127 128-255 0-127 128-255 0-127 128-255 0-127 128-255 0-127 128-255 0-63 64-127 128-191 192-255 0-63 64-127 128-191 192-255 0-63 64-127 128-191 192-255 0-63 64-95 96-127 128-159 160-191 192-223 224-255 Blackout Auto mode Sound mode Manual mode Select the Pattern Manually adjust the size Loop zoom in or out Manual rotation adjustment Set the speed of X-axis rotation Manual rotation adjustment rotation Set the speed of Y-axis rotation Manual rotation adjustment rotation Set the speed of Z-axis rotation Manually adjust the position 128~255Set the speed of Auto-left to right loop movement. Set the speed of left and right loop movement Manually adjust the position 128~255Set the speed of Auto-left to right loop movement. Set the speed of up and down loop movement NOT USED Own color Yellow Green Red Own color Pink Blue Red Own color Cyan Green Blue Own color Red Green Blue Yellow(Red&Green) Pink(Red&Blue) Cyan(Red&Blue) 7 IR REMOTE CONTROL DESCRIPTION: POWER: Power on or standby Mode AUTO: Auto Run Mode SOUND: Sound Active Mode WARRANTY Please refer to your local dealer or please contact Event Lighting. 8 LASER EMISSION DATA ALL * As measured under IEC measurement conditions for classification. Laser Classification Class 3B Beam Diameterr <5mm at aperture Diverg3ence(each beam) <12 mrad Divergence(total light) <90 degrees Transverse Beam Mode TEM00 Cooling Fan Cooling DM450B Blue Laser Medium LD InGaN 450nm, typical Laser Power:450mW 450nm Blue CW DM100G Green Laser Medium DPSS Nd:YVO4+KTP,532nm Laser Power: 100mW 532nm Green CW DM400RGB Green Laser Medium DPSS Nd:YVO4+KTP,532nm Red Laser Medium LD GaAIAs 650nm,typical Blue Laser Medium LD InGaN 450nm, typical Laser Power:200mW 650nm Red CW, 50mW 532nm Green CW, 150mW 450nm Blue CW DM200RGY Green Laser Medium DPSS Nd:YVO4+KTP,532nm Red Laser Medium LD GaAIAs 650nm,typical Laser Power:200mW 650nm Red CW, 50mW 532nm Green CW DM300RBP Red Laser Medium LD GaAIAs 650nm,typical Blue Laser Medium LD InGaN 450nm, typical Laser Power:150mW 650nm Red CW, 150mW 450nm Blue CW TDM-RGB400 Green Laser Medium DPSS Nd:YVO4+KTP,532nm Red Laser Medium LD GaAIAs 650nm,typical Blue Laser Medium LD InGaN 450nm, typical Laser Power:200mW 650nm Red CW, 50mW 532nm Green CW, 150mW 450nm Blue CW 9 SPECIFICTAIONS ALL Mains Input:AC100~240V, 50/60Hz Total Power:14W Laser Safety Standard:EN60825-1 2007 Condition Temperature:10~40 Measurement: 159mm x 90mm x 71mm DM450B Net Weight:0.84Kg DM100G Net Weight:0.85Kg DM400RGB Net Weight:0.91Kg DM200RGY Net Weight:0.85Kg DM300RBP Net Weight:0.85Kg TDM400RGB Net Weight:0.92KgPDF Printer / www.bullzip.com / CP / Freeware Edition