VEVOR HCT-378 Water Timer User Manual
This document provides comprehensive instructions for the VEVOR HCT-378 Water Timer, covering installation, operation, features, and troubleshooting. It is designed for efficient garden watering management.
Installing the Timer to Water Tap
Before Installation: Ensure the water inlet is equipped with a filter to prevent impurities from blocking the valve. Clean or replace the filter periodically. The timer requires tap water pressure or a pressurized water source to operate.
Installation Steps:
- Open the battery compartment cover and insert 2 new 1.5 V 'AA' alkaline batteries, observing the +/- polarity marks.
- Attach the water timer (with built-in filter) to an outdoor water tap.
- Use an O-ring, adapter, or PTFE tape as needed to prevent water leakage.
- Connect water pipes to the zone outlets using quick connectors if necessary.
Important Notes:
- Intended for outdoor use only.
- Hand-tighten connections; do not use tools on the timer.
- Do not use water with temperatures below 3°C or above 45°C.
Components
The water timer consists of the following parts:
- Water Inlet with 3/4" internal thread
- LCD Display
- Control Buttons
- Battery Compartment Cover
- Zone Outlets with 3/4" external thread
LCD Display Indicators
The LCD display shows various indicators:
- 1. Current Time: Displays the current time in 24-hour format.
- 2. Battery Power: Indicates the battery power level [?].
- 3. Delay Mode: Indicates that the Delay mode is active [⏳].
- 4. Watering: Indicates that the timer is currently watering [?].
- 5. Child Lock Mode: Indicates that the Child Lock mode is active [?].
- 6. Selected Zone: Indicates the currently selected zone area (A, B, or C).
- 7. First Watering Time: Shows the first watering time for each program.
- 8. Run Time: Allows setting run time from 1-59 seconds or 1-360 minutes.
- 9. Interval Period: Allows setting the interval between watering from 1-23 hours or 1-15 days.
- 10. Automatic Reminder: Shows time remaining until the next watering starts.
Note: Please replace batteries in time. If the battery is too weak to open the valve, the timer cannot water.
Control Buttons
The timer has the following control buttons:
- 1. [Set Time Button]: Allows setting the current time.
- 2. [Zone Select Button]: Selects Zone A, B, or C for program setup.
- 3. [Return/Cancel Button]: Returns to the main screen. Hold for 3 seconds to discontinue programs.
- 4. [Manual Water Button]: Activates a one-time watering for a single zone.
- 5. [- Button]: Decreases the selected flashing item on the display.
- 6. [+] Button: Increases the selected flashing item on the display. Hold for 3 seconds to postpone watering for an interval period.
- 7. [Enter/Confirm Button]: Enters program setup or confirms set options.
- 8. [Function Button]: Activates Child Lock mode (hold [+] and [-] buttons together for 3 seconds).
Programming the Water Timer
Set Current Time
- Press the [Set Time Button].
- The current hour will flash. Use the [+] and [-] buttons to change the hour, then press the [Enter/Confirm Button] to save and proceed to set the minute.
- The current minute will flash. Use the [+] and [-] buttons to change the minute, then press the [Enter/Confirm Button] to save and automatically return to the main screen.
- The current time is now set.
Set Start Time, Run Time, and Interval Period
- Press the [Zone Select Button] and choose the target zone, then press the [Enter/Confirm Button] to enter the start time setting.
- The hour will flash. Use the [+] and [-] buttons to change it, then press the [Enter/Confirm Button] to save and proceed to set the minute.
- The minute will flash. Use the [+] and [-] buttons to change it, then press the [Enter/Confirm Button] to save and proceed to the run time setting.
- The run time number will flash. Use the [+] and [-] buttons to change it from 1-59 seconds or 1-360 minutes, then press the [Enter/Confirm Button] to save and proceed to the interval period setting.
- The interval period number will flash. Use the [+] and [-] buttons to change it from 1-23 hours or 1-15 days, then press the [Enter/Confirm Button] to save.
- Start time, run time, and interval period for the zone are now set. The "Next Start" time will update automatically in real-time.
Key Features
Manual Watering for Single Zone
This feature allows manual watering for a single zone without interrupting the set program.
- Press the [Zone Select Button] to select the desired zone, then press the [Manual Water Button] to enter the setting.
- The run time number will flash. Use the [+] and [-] buttons to change it (1-59 sec or 1-360 min), then press the [Manual Water Button] to start watering for the selected zone only.
- A stopwatch will start, and the [?] indicator will flash on the screen.
- To cancel manual watering midway, press the [Manual Water Button] again.
Delay Mode for All Zones
This feature allows postponing watering for all zones for a set interval without interrupting the preset program.
- Press any button to light up the screen.
- Hold the [Delay Button] (Button 6) for 3 seconds. The [⏳] indicator will flash on the screen, and the next start time will be updated.
- To cancel Delay mode midway, hold the [Delay Button] (Button 6) for 3 seconds again.
Child Lock Mode for All Zones
This feature prevents accidental operation and protects the timer from children's interference.
- Press any button to light up the screen.
- Hold the [+] and [-] buttons together for 3 seconds. The [?] indicator will show on the screen.
- To cancel Child Lock mode, hold the [+] and [-] buttons together for 3 seconds again.
OFF Mode for Single Zone
This feature allows users to temporarily disable the watering program for a selected zone. The program is saved and will resume after OFF mode is removed.
- Press the [Zone Select Button] to select the desired zone.
- Hold the [Return/Cancel Button] (Button 3) for 3 seconds. The "OFF" indicator will show on the screen for the selected zone.
- To remove OFF mode, hold the [Return/Cancel Button] (Button 3) for 3 seconds again.
Low Power OFF Mode
The water timer automatically enters Low Power OFF mode when the battery power is low. The [⚡] indicator will flash, and the timer will not be able to water. Replace batteries promptly and reset programs.
View / Choose Watering Zones
To save battery power, the LCD display turns off after 30 seconds of inactivity. Press any button to wake the display.
- Press the [Zone Select Button] repeatedly to cycle through Zone A, Zone B, and Zone C displays.
- The following diagrams illustrate the factory preset programs for each zone:
- Zone A program
- Zone B program
- Zone C program
Tips: To ensure normal water output for each zone, do not open 2-3 zones simultaneously.
Troubleshooting
No display when batteries are installed: Check battery power. Ensure new batteries are inserted correctly according to +/- marks.
Display reads "Er00", "Er01", "Er02": Circuit is in an abnormal state. Reinstall the batteries.
Water does not come out at the preset time:
- A program might be currently setting up for the zone.
- Delay mode or OFF mode is active. Clear these modes if necessary.
- Low Power OFF mode is active. Replace the batteries.
- The faucet is turned off. Turn it on.
Water inlet/outlet leaks:
- The filter may not be properly seated at the tap connection. Reinstall it correctly.
- The water inlet/outlet or water pipe may be damaged. Check for damage.
- The water tap or pipe may have a different thread size than the timer. Use an appropriate adapter, O-ring, quick connector, or PTFE tape if needed.
Specifications
Item | Specification |
---|---|
Model | HCT-378 |
Item Size | 138×72×127 mm |
Net Weight | 510 ± 10 g |
Ingress Protection | IPX5 |
Power Supply | 2 × 1.5 V 'AA' Alkaline Batteries |
Run Time (How Long) | From 1 - 59 seconds or 1 - 360 minutes |
Interval Period (How Often) | From 1 - 23 hours or 1 - 15 days |
Working Pressure | 0.05 - 0.8 MPa |
Working Temperature | 3 - 45°C |
Water Inlet | 3/4" Internal Thread |
Water Outlet | 3/4" External Thread |
Manufacturer and Support Information
Manufacturer: Ningbo Hanci Electrical Co., LTD. No.127-129, Dexing Road, Ninghai County, Ningbo City, China. 315600
Support and E-Warranty: www.vevor.com/support
Distributors Mentioned: E-CrossStu GmbH, YH CONSULTING LIMITED.