FSP260-P35 A Series
Description of the physical appearance of the power supply unit: A compact, rectangular AC-DC switching power supply with a metal casing, featuring a fan for cooling and various input/output connectors.
Features
- Class-I design
- IEC 62368-1 safety standard
- Form factor 3" x 5" x 1.34"
- Input power less than 0.5W at 0.2W load
- EN 55032 radiated emission compliance
- Remote ON/OFF input
- High altitude 5000 meters operation
- Long hold up time
Safety Standard Approval
CE, cURus (E190414)
Description
This AC-DC switching power supply is a Class-I (with Protection Earth) safety construction, packaged in a 3 x 5 inches form factor. It features 0.5W low input power consumption at 0.2W load, complying with Energy Star requirements. Its low audible noise makes it suitable for quiet design environments. The PSU can deliver 260 watts continuous power with 18.4 CFM forced air cooling or 150 watts continuous power with convection cooling at 50°C operation temperature. It is suitable for information, audio & video, and networking applications.
Specifications
Input Specifications
Input voltage: | 90 to 264 VAC |
Input frequency: | 47-63 Hz |
Input current: | 3 A (rms) for 115 VAC 1.5 A (rms) for 230 VAC |
Earth leakage current: | 1.5 mA maxi. @ 264VAC, 63Hz |
Touch current: | 250 µA maxi. @ 264VAC, 63Hz |
Remote ON/OFF: | TTL Low level to turn on PSU |
Output Specifications
Output voltage/current: | See rating chart. |
Total output power: | 260 watts maximum |
Ripple and noise: | 1% peak to peak maximum |
Protection: | OVP: Latch off OCP & Shorted: Auto recovery OTP: Latch off |
Temperature coefficient: | All outputs ±0.04% /°C maximum |
Transient response: | Maximum excursion of 4% or better on all models, recovering to 1% of final value within 500 µs after a 25% step load change. |
Environmental Specifications
Operating temperature: | -20°C to +70°C |
Storage temperature: | -40°C to +85°C |
Relative humidity: | 5% to 95% non-condensing |
Derating: | Derate from 100% at +50°C linearly to 50% at +70°C, applicable to convection and forced-air cooling conditions. |
General Specifications
Power factor: | 0.99 mini. @ 115VAC & 100% load 0.94 mini. @ 230VAC & 100% load |
Efficiency: | Refer to rating table |
Turn-On Delay Time: | ≤ 1 sec at 115 VAC |
Hold-up time: | 25 mS mini. @ 115VAC & 260W load 50 mS mini. @ 115VAC & 150W load |
Line regulation: | ±0.2% maximum at full load |
Inrush current: | 60A @ 115VAC, 25°C & cold start 120A @ 230VAC, 25°C & cold start |
Withstand voltage: | 3000 VAC from input to output 1500 VAC from input to ground, 1500 VAC from output to ground |
Isolation resistance: | Input to output 100M ohm @ 500Vdc |
MTBF: | 800,000 hours mini. at full load at 25°C ambient temperature, calculated per Telcordia SR-332 |
EMC Performance
EN 55032: | Class B conducted, class B radiated |
FCC: | Class B conducted, class B radiated |
VCCI: | Class B conducted, class B radiated |
EN61000-3-2: | Harmonic distortion, class A and D |
EN61000-3-3: | Line flicker |
EN61000-4-2: | ESD, ±8 KV air and ±4 KV contact |
EN61000-4-3: | Radiated immunity, 3 V/m |
EN61000-4-4: | Fast transient/burst, ±1 KV |
EN61000-4-5: | Surge, ±2 KV diff., ±4 KV com. |
EN61000-4-6: | Conducted immunity, 3 V/m |
EN61000-4-8: | Magnetic field immunity, 1 A/m |
EN61000-4-11: | Voltage dip immunity & voltage interruptions 30% reduction for 500 ms >95% reduction for 10 mS 100% reduction for 5000 ms |
Performance Curves
Output Power Derating Curve (Temperature)
Line graph showing "% Output Power" on the Y-axis versus "Temperature (°C)" on the X-axis. The curve indicates that output power is derated from 100% at 50°C down to 50% at 70°C.
Output Power Derating Curve (Input Voltage)
Line graph showing "% Output Power" on the Y-axis versus "Input Voltage (Vac)" on the X-axis. The curve shows that output power remains at 100% across the input voltage range from approximately 90 VAC to 270 VAC.
Output Voltage/Current Rating Chart
Model | V1 | Min. Current | Max. Current (1) | Tol. | Ripple & Noise (2) | Max. Power (1) | Efficiency (typical) @ 115/230 VAC |
||
---|---|---|---|---|---|---|---|---|---|
Convection | Forced air | Convection | Forced air | ||||||
FSP260-P35-A12 | 12 V | 0 A | 12.50A | 21.60A | ±3% | 120 mV | 150W | 260W | 90/92% |
FSP260-P35-A18* | 18 V | 0 A | 8.33A | 14.45A | ±3% | 180 mV | 150W | 260W | 91/92% |
FSP260-P35-A24 | 24 V | 0 A | 6.25A | 10.80A | ±3% | 240 mV | 150W | 260W | 91/92% |
FSP260-P35-A54 | 54 V | 0 A | 2.78A | 4.82A | ±3% | 540 mV | 150W | 260W | 92/94% |
Notes:
- 1. Forced air 18.4 CFM to be provided by user.
- 2. Ripple and noise is maximum peak to peak voltage value measured at output within 20 MHz bandwidth, at rated line voltage and output load ranges, and with a 10 µF tantalum (or electrolytic) capacitor in parallel with a 0.1 µF ceramic capacitor across the output.
- 3. Please contact with sales representative for safety application schedule.
Mechanical Specifications
Dimensions are shown in millimeters (mm).
Technical drawing illustrating the physical layout and dimensions of the power supply unit. Key dimensions include overall length (127.00±0.5 mm), width (115.80±0.5 mm), and height (32.5 mm max). It also shows the placement of connectors CN200 and CN201, and the ground tab.
Connector Pin Chart
CONNECTOR | CN200 | CN201 | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
PIN NO. | 1 | 2 | 3 | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
OUTPUT | Line | N.C. | Neutral | +Vout | Return | PS_OFF + | PS_OFF - |
Notes:
- 1. Dimensions shown in mm.
- 2. Connector IN1: JST B2P3-VH or equivalent.
- 3. Connector CN200: Molex 460271208 or equivalent.
- 4. Connector CN201: JST B2B-PH.
- 5. Ground tab: 8 x 6.35 x 0.8 mm.
Weight: 280 grams (0.617 lbs.) approx.