CommScope TeraSPEED N-144-MP-8W-F12YL/D Fiber Optic Cable

Product Number: 760050476

Product Description

Fiber indoor cable, TeraSPEED® Low Smoke Zero Halogen Riser MPO Trunk, 144 fiber multi-unit with 12 fiber subunits, Gel-free, Singlemode G.652.D and G.657.A1, Feet jacket marking, Yellow jacket color, Dca flame rating.

Product Classification

Portfolio: CommScope®

Product Type: Fiber indoor cable

Product Series: N-MP

Regional Availability: Asia | Australia/New Zealand | EMEA | Latin America | North America

General Specifications

Cable TypeMPO trunk cable
Construction TypeNon-armored
Subunit TypeGel-free
Jacket ColorYellow
Jacket MarkingFeet
Subunit, quantity12
Fibers per Subunit, quantity12
Total Fiber Count144

Dimensions

Buffer Tube/Subunit Diameter3 mm | 0.118 in
Diameter Over Jacket14.22 mm | 0.56 in

Representative Image Description

A cross-section diagram of the fiber optic cable showing its construction: an outer yellow jacket, a ripcord, 12 fiber subunits, and aramid yarn for strength.

Mechanical Specifications

Minimum Bend Radius, loaded200 mm | 7.874 in
Minimum Bend Radius, unloaded133 mm | 5.236 in
Tensile Load, long term, maximum400 N | 89.924 lbf
Tensile Load, short term, maximum1335 N | 300.12 lbf
Compression10 N/mm | 57.101 lb/in
Compression Test MethodFOTP-41 | IEC 60794-1 E3
Flex300 cycles
Flex Test MethodFOTP-104 | IEC 60794-1 E6
Impact2.94 N-m | 26.021 in lb
Impact Test MethodFOTP-25 | IEC 60794-1 E4
Strain Test MethodFOTP-33 | IEC 60794-1 E1
Twist10 cycles
Twist Test MethodFOTP-85 | IEC 60794-1 E7
Vertical Rise, maximum280 m | 918.635 ft

Optical Specifications

Fiber Type: G.652.D and G.657.A1, TeraSPEED® | OS2 | OS2

Wavelength Specific Specifications

Attenuation, maximum0.40 dB/km @ 1,310 nm | 0.40 dB/km @ 1,385 nm | 0.40 dB/km @ 1,490 nm | 0.40 dB/km @ 1,550 nm | 0.50 dB/km @ 1,270 nm | 0.50 dB/km @ 1,575 nm
Backscatter Coefficient-79.6 dB @ 1,310 nm | -82.1 dB @ 1,550 nm
Dispersion, maximum18 ps(nm-km) at 1550 nm | 3.5 ps(nm-km) from 1285 nm to 1330 nm at 1310 nm
Index of Refraction1.467 @ 1,310 nm | 1.467 @ 1,385 nm | 1.468 @ 1,550 nm
Mode Field Diameter10.4 µm @ 1,550 nm | 9.2 µm @ 1,310 nm | 9.6 µm @ 1,385 nm
Mode Field Diameter Tolerance±0.4 µm @ 1310 nm | ±0.5 µm @ 1550 nm | ±0.6 µm @ 1385 nm
Polarization Mode Dispersion Link Design Value, maximum0.06 ps/sqrt(km)
Standards ComplianceITU-T G.652.D | ITU-T G.657.A1 | TIA-492CAAB (OS2)

Environmental Specifications

Installation temperature-20 °C to +60 °C (-4 °F to +140 °F)
Operating Temperature-20 °C to +70 °C (-4 °F to +158 °F)
Storage Temperature-40 °C to +70 °C (-40 °F to +158 °F)
Heat Age, maximum0.05 dB/km @ 85 °C
Temperature Dependence, maximum0.05 dB/km
Temperature Humidity Cycling, maximum0.05 dB/km
Water Immersion, maximum0.05 dB/km @ 23 °C

Environmental Test Specifications

Heat Age Test MethodIEC 60794-1 F9
Low High Bend-20 °C to +70 °C (-4 °F to +158 °F)
Low High Bend Test MethodFOTP-37 | IEC 60794-1 E11
Temperature Cycle-20 °C to +70 °C (-4 °F to +158 °F)
Temperature Cycle Test MethodFOTP-3 | IEC 60794-1 F1

Cable Qualification Standards & Certifications

Cable Qualification StandardsANSI/ICEA S-83-596 | Telcordia GR-409
EN50575 CPR Cable EuroClass Fire PerformanceDca
EN50575 CPR Cable EuroClass Smoke Ratings1a
EN50575 CPR Cable EuroClass Droplets Ratingd1
EN50575 CPR Cable EuroClass Acidity Ratinga1
Environmental SpaceLow Smoke Zero Halogen (LSZH) | Riser
Flame Test ListingNEC OFNR-ST1 (ETL) and c(ETL)
Flame Test MethodIEC 60332-3 | IEC 60754-2 | IEC 61034-2 | UL 1666 | UL 1685

Regulatory Compliance/Certifications

AgencyClassification
CENELECEN 50575 compliant, Declaration of Performance (DoP) available
CHINA-ROHSBelow maximum concentration value
ISO 9001:2015Designed, manufactured and/or distributed under this quality management system
REACH-SVHCCompliant as per SVHC revision on www.commscope.com/ProductCompliance
ROHSCompliant
UK-ROHSCompliant

Included Products

  • CS-8W-MP TeraSPEED® OS2 Singlemode

Footnotes

Operating Temperature: Specification applicable to non-terminated bulk fiber cable.

Temperature Dependence, maximum: Temperature dependence is conducted at -60 °C to +85 °C (-76 °F to +185 °F).

Temperature Humidity Cycling, maximum: Temperature humidity cycling is conducted at -10 °C to +85 °C (+14 °F to +185 °F) up to 95% relative humidity.

PDF preview unavailable. Download the PDF instead.

760050476-product-specifications-comprehensive COMMSCOPE

Related Documents

Preview CommScope N-144-MP-8W-F12YL/D TeraSPEED Fiber Optic Cable Specifications
Detailed specifications for the CommScope N-144-MP-8W-F12YL/D TeraSPEED fiber optic cable, including product classification, general, mechanical, optical, and environmental specifications, as well as regulatory compliance.
Preview CommScope TeraSPEED N-024-MP-8W-F12YL/D: 24-Fiber Singlemode MPO Trunk Cable Specifications
Detailed specifications for the CommScope TeraSPEED N-024-MP-8W-F12YL/D fiber optic cable. This 24-fiber, LSZH riser MPO trunk cable features Singlemode G.652.D and G.657.A1 fibers, yellow jacket, and Dca flame rating.
Preview CommScope P-012-MZ-8W-F12YL TeraSPEED Plenum MPO Trunk Cable Specifications
Detailed technical specifications for the CommScope P-012-MZ-8W-F12YL TeraSPEED Plenum MPO Trunk Cable, including mechanical, optical, environmental, and regulatory compliance details. Features 12 fibers, interlocking aluminum armor, and yellow plenum jacket.
Preview CommScope N-024-MP-8W-F12YL/D Fiber Optic Cable Datasheet
Technical specifications for the CommScope N-024-MP-8W-F12YL/D TeraSPEED Low Smoke Zero Halogen (LSZH) Riser MPO Trunk fiber indoor cable, detailing its construction, performance, and compliance.
Preview CommScope P-072-MP-8W-F12GR TeraSPEED® Plenum MPO Trunk Cable: Technical Specifications and Fiber Details
Detailed technical specifications for the CommScope P-072-MP-8W-F12GR TeraSPEED® Plenum MPO Trunk Cable, including its included CS-8W-MP Singlemode Fiber specifications, mechanical, optical, and environmental properties.
Preview CommScope TeraSPEED® Z-144-MP-8W-F12BK/D Fiber Optic Cable Specifications
Detailed technical specifications for the CommScope TeraSPEED® Z-144-MP-8W-F12BK/D Fiber Indoor/Outdoor MPO Trunk Cable, including mechanical, optical, environmental, and compliance data.
Preview CommScope Fiber Optic Cable Specifications: TeraSPEED® Plenum MPO Trunk, LazrSPEED® 300 OM3, and TeraSPEED® OS2
Detailed technical specifications for CommScope's P-072-MP-CM-F12AQ/8W036/5L036 TeraSPEED® Plenum MPO Trunk cable, including CS-5L-MP LazrSPEED® 300 OM3 and CS-8W-MP TeraSPEED® OS2 fiber types. Covers product classification, general, mechanical, optical, and environmental specifications, along with regulatory compliance.
Preview CommScope Z-144-MP-8W-F12BK/D TeraSPEED Fiber Optic Cable Specifications
Detailed specifications for the CommScope Z-144-MP-8W-F12BK/D TeraSPEED fiber optic cable, including mechanical, optical, environmental, and regulatory compliance data. Features 144 fibers, LSZH jacket, and Dca flame rating.