Roth Vipanel® Bulk
The Norwegian EPD Foundation
Owner of the declaration: Roth North Europe A/S
Program operator: The Norwegian EPD Foundation
Declaration number: NEPD-11297-11240
Declared unit: 1 m²
Registration number: NEPD-11297-11240
This declaration is based on Product Category Rules: CEN Standard EN 15804:2012+A2:2019 serves as core PCR and NPCR - Part B 010 Part B for Building Boards. Ver. 4.0 NPCR 010:2022 Part B for building boards
Issue date: 03.06.2025
Valid to: 03.06.2030
EPD software: LCAno EPD generator ID: 819070
General Information
Product
Roth Vipanel® Bulk
Program operator
The Norwegian EPD Foundation
Post Box 5250 Majorstuen, 0303 Oslo, Norway
Phone: +47 977 22 020
web: www.epd-norge.no
Declaration number
NEPD-11297-11240
Statement of liability
The owner of the declaration shall be liable for the underlying information and evidence. EPD Norway shall not be liable with respect to manufacturer information, life cycle assessment data and evidences.
Declared unit
1 m² Roth Vipanel® Bulk
Declared unit with option
A1-A3, A4, A5, C1, C2, C3, C4, D
Functional unit
General information on verification of EPD from EPD tools:
Independent verification of data, other environmental information and the declaration according to ISO 14025:2010, § 8.1.3 and § 8.1.4. Verification of each EPD is made according to EPD-Norway's guidelines for verification and approval requiring that tools are i) integrated into the company's environmental management system, ii) the procedures for use of the EPD tool are approved by EPD-Norway, and iii) the process is reviewed annually by an independent third party verifier. See Appendix G of EPD-Norway's General Programme Instructions for further information on EPD tools.
Verification of EPD tool:
Independent third party verification of the EPD tool, background data and test-EPD in accordance with EPDNorway's procedures and guidelines for verification and approval of EPD tools.
Third party verifier:
Owner of the declaration
Roth North Europe A/S
Contact person: Stine Bøgh Petersen
Phone: +45 47 33 97 00
e-mail: sustainability@roth-northeurope.com
Manufacturer
Roth North Europe A/S
Place of production
Roth North Europe A/S
Centervej 5
3600 Frederikssund, Denmark
Management system
EN ISO 9001:2015, EN ISO 14001:2015
Organisation no
34012113
Issue date
03.06.2025
Valid to
03.06.2030
Year of study
2024
Comparability
EPD of construction products may not be comparable if they not comply with EN 15804 and seen in a building context.
Development and verification of EPD
The declaration is created using EPD tool lca.tools ver EPD2022.03, developed by LCA.no. The EPD tool is integrated in the company's management system, and has been approved by EPD Norway.
Developer of EPD: Stine Bøgh Petersen
Reviewer of company-specific input data and EPD: Kim Haugsted Neubert
Approved
Håkon Hauan, CEO EPD-Norge
Elisabet Amat, GREENIZE projects (no signature required)
Product Description and Specification
Product description
Roth Vipanel® is a composite aluminium wallpanel with two layers of 0.2 mm facing LDPE type polyethylene core. The Roth Vipanel® can be worked with normal tools and machines.
Roth Vipanel® has the ability to be mounted edge-to-edge and to make both inside and outside corners with or without the use of aluminium profiles. Installing the Roth Vipanel® without the use of profiles gives the appearance of almost invisible connections. It is not recommended to install glossy wallpanels without profiles.
Product Image Description
A visual representation of the product's layered structure, illustrating distinct layers of aluminium and polyethylene.
Product specification
Materials | Value | Unit |
---|---|---|
Aluminium | 40-50 | % |
Polyethylene, PE | 50-60 | % |
Packaging, Plastic film | 0-5 | % |
Technical data
Height: 2.050 mm, 2.100 mm, 2.550 mm
Width: 1.000 mm, 1.500 mm
Weight: 3.80 kg/m²
Fire Class:
B2 according to DIN 4102-1 (German Norm)
M2 according to NF-P-92-501 (French Norm)
Class D-s2,d2 according to EN13501-1 (European Norm)
VOC emission acc. to ISO-16000 Level (A+)
Market
Denmark, Sweden, Norway, Finland & UK
Reference service life, product
50 years (Haugbølle, K., et.al, 2022)
Reference service life, building
50 years (Haugbølle, K., et.al, 2022)
LCA: Calculation rules
Declared unit
1 m² Roth Vipanel® Bulk
Cut-off criteria
All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) are not included when specific information are missing. These cut-off criteria do not apply for hazardous materials and substances.
Allocation
The allocation is made in accordance with the provisions of EN 15804. Incoming energy and water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis.
Data quality
Specific data for the product composition are provided by the manufacturer. They represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on registered EPDs according to EN 15804, Ostfold Research databases, ecoinvent and other LCA databases. The data quality of the raw materials in A1 is presented in the table below.
Materials | Source | Data quality | Year |
---|---|---|---|
Building boards | Supplier | EPD | 2020 |
Packaging - Plastic | ecoinvent 3.6 | Database | 2019 |
Varnish | ecoinvent 3.6 | Database | 2019 |
System Boundaries
System boundaries (X=included, MND=module not declared, MNR=module not relevant)
Product stage | Raw materials | Transport | Manufacturing | Transport | Assembly | Use stage | End of life stage | Beyond the system boundaries | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
A1 | A2 | A3 | A4 | A5 | B1 | B2 | B3 | B4 | B5 | B6 | B7 | C1 | C2 | C3 | C4 | D | |
X | X | X | X | X | MND | MND | MND | MND | MND | MND | MND | X | X | X | X | X |
System boundary explanation
Module A1: Packaging has been included by average use of packaging pr. 1 m² of product.
Module A4: The transportation distances provided in this EPD are derived from precise data concerning the distances between production facility and various sales departments in different countries. Distribution from each of the sales departments to the end customers a distance of 300 km* is assumed.
*Transportation by truck is assumed on a distribution of 80% EURO 6 and 20% EURO 5, based on data from the company's own logistics provider.
Module A5/C1: Manual installation and demolition has been assumed.
Module C2: The estimated transportation distance to the waste handling facility in this EPD is 100 km, assuming the use of a truck as the transport method.
Additional technical information
No technical information declared.
LCA: Scenarios and Additional Technical Information
Transport from production place to user (A4)
Capacity utilisation (incl. return) % | Distance (km) | Fuel/Energy Consumption | Unit | Value (Liter/tonne) | |
---|---|---|---|---|---|
Ship, Freight, Transoceanic (km) | 65,0% | 165 | 0,003 | l/tkm | 0,50 |
Truck, 16-32 tonnes, EURO 5 (km) - Europe | 36,7% | 60 | 0,044 | l/tkm | 2,64 |
Truck, 16-32 tonnes, EURO 5 (km) - Europe | 36,7% | 199 | 0,044 | l/tkm | 8,77 |
Truck, 16-32 tonnes, EURO 5 (km) - Europe | 36,7% | 88 | 0,044 | l/tkm | 3,86 |
Truck, 16-32 tonnes, EURO 6 (km) - Europe | 36,7% | 351 | 0,043 | l/tkm | 15,10 |
Truck, 16-32 tonnes, EURO 6 (km) - Europe | 36,7% | 798 | 0,043 | l/tkm | 34,30 |
Truck, 16-32 tonnes, EURO 6 (km) - Europe | 36,7% | 240 | 0,043 | l/tkm | 10,32 |
Assembly (A5)
Unit | Value | |
---|---|---|
Waste, packaging, plastic film (LDPE), to average treatment (kg) | kg | 0,050 |
Waste of product during installation (Declared unit) | Units | 0,13 |
Transport to waste processing (C2)
Capacity utilisation (incl. return) % | Distance (km) | Fuel/Energy Consumption | Unit | Value (Liter/tonne) | |
---|---|---|---|---|---|
Truck, 16-32 tonnes, EURO 5 (km) - Europe | 36,7% | 100 | 0,044 | l/tkm | 4,40 |
Waste processing (C3)
Unit | Value | |
---|---|---|
Waste, Materials to recycling (kg) | kg | 0,88 |
Waste treatment per kg Polyethylene (PE), incineration with fly ash extraction (kg) | kg | 2,80 |
Waste treatment per kg Varnish, hazardous waste incineration (kg) | kg | 0,039 |
Disposal (C4)
Unit | Value | |
---|---|---|
Landfilling of ashes from incineration of Polyethylene (PE), process per kg ashes and residues (kg) | kg | 0,098 |
Waste, scrap aluminium, to landfill (kg) | kg | 0,066 |
Landfilling of ashes from incineration of Paint, hazardous waste incineration, process per kg ashes and residues (kg) | kg | 0,0011 |
Benefits and loads beyond the system boundaries (D)
Unit | Value | |
---|---|---|
Substitution of electricity (MJ) | MJ | 5,43 |
Substitution of thermal energy, district heating (MJ) | MJ | 82,29 |
Substitution of primary aluminium with net scrap (kg) | kg | 0,30 |
LCA: Results - Environmental Impact
The LCA results are presented below for the declared unit defined on page 2 of the EPD document.
Environmental impact Indicator | Unit | A1-A3 | A4 | A5 | C1 | C2 | C3 | C4 | D |
---|---|---|---|---|---|---|---|---|---|
GWP-total | kg CO2-eq | 2,53E+01 | 1,10E+00 | 1,92E+00 | 0 | 6,42E-02 | 8,59E+00 | 6,81E-03 | -3,23E+00 |
GWP-fossil | kg CO2-eq | 2,52E+01 | 1,10E+00 | 1,92E+00 | 0 | 6,42E-02 | 8,59E+00 | 6,81E-03 | -3,15E+00 |
GWP-biogenic | kg CO2-eq | 6,96E-02 | 4,54E-04 | 3,74E-03 | 0 | 2,62E-05 | 4,58E-04 | 6,12E-06 | -1,33E-02 |
GWP-luluc | kg CO2-eq | 6,60E-03 | 3,93E-04 | 3,94E-04 | 0 | 2,24E-05 | 2,23E-05 | 1,24E-06 | -6,72E-02 |
ODP | kg CFC11-eq | 1,71E-06 | 2,50E-07 | 2,01E-07 | 0 | 1,46E-08 | 1,43E-08 | 8,54E-10 | -3,48E-02 |
AP | mol H+-eq | 8,11E-02 | 3,62E-03 | 5,18E-03 | 0 | 2,62E-04 | 1,17E-03 | 2,73E-05 | -2,20E-02 |
EP-Fresh Water | kg P-eq | 1,75E-04 | 8,75E-06 | 2,03E-05 | 0 | 5,04E-07 | 8,56E-07 | 9,71E-08 | -1,46E-04 |
EP-Marine | kg N-eq | 1,73E-02 | 8,15E-04 | 1,16E-03 | 0 | 7,78E-05 | 5,29E-04 | 8,81E-06 | -3,57E-03 |
EP-Terrestial | mol N-eq | 1,91E-01 | 9,07E-03 | 1,29E-02 | 0 | 8,60E-04 | 5,74E-03 | 1,00E-04 | -3,90E-02 |
POCP | kg NMVOC-eq | 6,34E-02 | 3,18E-03 | 4,31E-03 | 0 | 2,63E-04 | 1,40E-03 | 2,78E-05 | -1,23E-02 |
ADP-minerals&metals¹ | kg Sb-eq | 6,35E-05 | 3,02E-05 | 5,31E-06 | 0 | 1,74E-06 | 4,06E-07 | 3,77E-08 | -6,41E-07 |
ADP-fossil¹ | MJ | 4,77E+02 | 1,66E+01 | 2,65E+01 | 0 | 9,68E-01 | 1,04E+00 | 7,25E-02 | -4,08E+01 |
WDP¹ | m³ | 1,55E+02 | 1,60E+01 | 1,88E+01 | 0 | 9,23E-01 | 3,36E+00 | 1,13E+00 | -1,62E+03 |
GWP-total = Global Warming Potential total; GWP-fossil = Global Warming Potential fossil fuels; GWP-biogenic = Global Warming Potential biogenic; GWP-luluc = Global Warming Potential land use and land use change; ODP = Depletion potential of the stratospheric ozone layer; AP = Acidification potential, Accumulated Exceedance; EP-freshwater = Eutrophication potential, fraction of nutrients reaching freshwater end compartment: EP-marine = Eutrophication potential, fraction of nutrients reaching marine end compartment; EP-terrestrial = Eutrophication potential, Accumulated Exceedance; POCP = Formation potential of tropospheric ozone; ADP-minerals&metals = Abiotic depletion potential for non-fossil resources; ADP-fossil = Abiotic depletion for fossil resources potential; WDP = Water (user) deprivation potential, deprivation-weighted water consumption
*Reading example: 9,0 E-03 = 9,0*10-3 = 0,009
*INA Indicator Not Assessed
1. The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experienced with the indicator
Remarks to environmental impacts
Additional Environmental Impact Indicators
Indicator | Unit | A1-A3 | A4 | A5 | C1 | C2 | C3 | C4 | D |
---|---|---|---|---|---|---|---|---|---|
PM | Disease incidence | 9,37E-07 | 6,95E-08 | 5,77E-08 | 0 | 4,62E-09 | 6,84E-09 | 3,68E-10 | -4,25E-07 |
IRP² | kgBq U235-eq | 1,93E+00 | 7,27E-02 | 1,06E-01 | 0 | 4,23E-03 | 3,28E-03 | 3,91E-04 | -1,91E-01 |
ETP-fw¹ | CTUe | 2,48E+02 | 1,23E+01 | 1,63E+01 | 0 | 7,13E-01 | 2,20E+00 | 4,15E+01 | -7,74E+01 |
HTP-c¹ | CTUh | 8,48E-09 | 0,00E+00 | 5,74E-10 | 0 | 0,00E+00 | 4,68E-10 | 7,00E-12 | -7,44E-09 |
HTP-nc¹ | CTUh | 3,89E-07 | 1,34E-08 | 2,11E-08 | 0 | 7,70E-10 | 7,61E-09 | 2,17E-10 | -1,14E-07 |
SQP¹ | dimensionless | 4,52E+01 | 1,16E+01 | 3,52E+00 | 0 | 6,67E-01 | 3,22E-01 | 2,08E-01 | -4,59E+01 |
PM = Particulate Matter emissions; IRP = Ionizing radiation human health; ETP-fw = Eco toxicity freshwater; HTP-c = Human toxicity cancer effects; HTP-nc = Human toxicity non cancer effects; SQP = Potential Soil Quality Index (dimensionless)
*Reading example: 9,0 E-03 = 9,0*10-3 = 0,009
*INA Indicator Not Assessed
1. The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experienced with the indicator
2. This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
Resource Use
Indicator | Unit | A1-A3 | A4 | A5 | C1 | C2 | C3 | C4 | D |
---|---|---|---|---|---|---|---|---|---|
PERE | MJ | 4,85E+01 | 2,37E-01 | 1,90E+00 | 0 | 1,37E-02 | 1,27E-01 | 6,22E-03 | -5,44E+01 |
PERM | MJ | 0,00E+00 | 0,00E+00 | 0,00E+00 | 0 | 0,00E+00 | 0,00E+00 | 0,00E+00 | 0,00E+00 |
PERT | MJ | 4,85E+01 | 2,37E-01 | 1,90E+00 | 0 | 1,37E-02 | 1,27E-01 | 6,22E-03 | -5,44E+01 |
PENRE | MJ | 4,75E+02 | 1,66E+01 | 2,62E+01 | 0 | 9,68E-01 | 1,04E+00 | 7,25E-02 | -4,08E+01 |
PENRM | MJ | 2,53E+00 | 0,00E+00 | -1,80E+00 | 0 | 0,00E+00 | 0,00E+00 | 0,00E+00 | 0,00E+00 |
PENRT | MJ | 4,78E+02 | 1,66E+01 | 2,44E+01 | 0 | 9,68E-01 | 1,04E+00 | 7,25E-02 | -4,08E+01 |
SM | kg | 4,87E-01 | 0,00E+00 | 1,60E-02 | 0 | 0,00E+00 | 0,00E+00 | 0,00E+00 | 0,00E+00 |
RSF | MJ | 5,79E-01 | 8,47E-03 | 7,48E-02 | 0 | 4,89E-04 | 2,75E-03 | 1,42E-04 | -1,24E-02 |
NRSF | MJ | 2,32E-01 | 3,04E-02 | 2,80E-02 | 0 | 1,74E-03 | 0,00E+00 | 1,08E-02 | -2,48E+00 |
FW | m³ | 1,43E-01 | 1,77E-03 | 6,40E-03 | 0 | 1,02E-04 | 1,65E-03 | 7,54E-05 | -1,18E-01 |
PERE = Use of renewable primary energy excluding renewable primary energy resources used as raw materials; PERM = Use of renewable primary energy resources used as raw materials; PERT = Total use of renewable primary energy resources; PENRE = Use of non renewable primary energy excluding non-renewable primary energy resources used as raw materials; PENRM = Use of non renewable primary energy resources used as raw materials; PENRT = Total use of non renewable primary energy resources; SM = Use of secondary materials; RSF = Use of renewable secondary fuels; NRSF = Use of non-renewable secondary fuels; FW = Net use of fresh water
*Reading example: 9,0 E-03 = 9,0*10-3 = 0,009
*INA Indicator Not Assessed
End of Life - Waste and Output Flow
End of life - Waste
Indicator | Unit | A1-A3 | A4 | A5 | C1 | C2 | C3 | C4 | D |
---|---|---|---|---|---|---|---|---|---|
HWD | kg | 9,52E-03 | 8,56E-04 | 3,94E-03 | 0 | 4,94E-05 | 0,00E+00 | 8,37E-02 | 1,09E-02 |
NHWD | kg | 3,31E+00 | 8,03E-01 | 2,19E-01 | 0 | 4,63E-02 | 0,00E+00 | 1,15E-01 | -9,37E-01 |
RWD | kg | 9,01E-03 | 1,13E-04 | 3,62E-04 | 0 | 6,60E-06 | 0,00E+00 | 3,03E-07 | -1,75E-04 |
HWD = Hazardous waste disposed; NHWD = Non-hazardous waste disposed; RWD = Radioactive waste disposed
*Reading example: 9,0 E-03 = 9,0*10-3 = 0,009
*INA Indicator Not Assessed
End of life - Output flow
Indicator | Unit | A1-A3 | A4 | A5 | C1 | C2 | C3 | C4 | D |
---|---|---|---|---|---|---|---|---|---|
CRU | kg | 0,00E+00 | 0,00E+00 | 0,00E+00 | 0 | 0,00E+00 | 0,00E+00 | 0,00E+00 | 0,00E+00 |
MFR | kg | 9,62E-02 | 0,00E+00 | 6,21E-02 | 0 | 0,00E+00 | 8,87E-01 | 0,00E+00 | 0,00E+00 |
MER | kg | 7,65E-03 | 0,00E+00 | 9,43E-02 | 0 | 0,00E+00 | 2,81E+00 | 0,00E+00 | 0,00E+00 |
EEE | MJ | 8,88E-03 | 0,00E+00 | 1,82E-01 | 0 | 0,00E+00 | 5,44E+00 | 0,00E+00 | 0,00E+00 |
EET | MJ | 1,34E-01 | 0,00E+00 | 2,75E+00 | 0 | 0,00E+00 | 8,23E+01 | 0,00E+00 | 0,00E+00 |
CRU = Components for re-use; MFR = Materials for recycling; MER = Materials for energy recovery; EEE = Exported energy electrical; EET = Exported energy thermal
*Reading example: 9,0 E-03 = 9,0*10-3 = 0,009
*INA Indicator Not Assessed
Biogenic Carbon Content
Indicator | Unit | At the factory gate |
---|---|---|
Biogenic carbon content in product | kg C | 0,00E+00 |
Biogenic carbon content in accompanying packaging | kg C | 0,00E+00 |
Note: 1 kg biogenic carbon is equivalent to 44/12 kg CO2
Additional Requirements and Information
Greenhouse gas emissions from the use of electricity in the manufacturing phase
National production mix from import, low voltage (production of transmission lines, in addition to direct emissions and losses in grid) of applied electricity for the manufacturing process (A3).
Electricity mix | Source | Amount | Unit |
---|---|---|---|
Electricity, Denmark (kWh) | ecoinvent 3.6 | 338,20 | g CO2-eq/kWh |
Electricity, Germany (kWh) | ecoinvent 3.6 | 585,93 | g CO2-eq/kWh |
Dangerous substances
The product contains no substances given by the REACH Candidate list.
Indoor environment
Not relevant. No tests have been carried out on the product concerning indoor environment.
Additional Environmental Information
Additional environmental impact indicators required in NPCR Part A for construction products
Indicator | Unit | A1-A3 | A4 | A5 | C1 | C2 | C3 | C4 | D |
---|---|---|---|---|---|---|---|---|---|
GWPIOBC | kg CO2-eq | 2,53E+01 | 1,10E+00 | 1,93E+00 | 0 | 6,42E-02 | 8,59E+00 | 7,02E-03 | -3,10E+00 |
GWP-IOBC: Global warming potential calculated according to the principle of instantaneous oxidation. In order to increase the transparency of biogenic carbon contribution to climate impact, the indicator GWP-IOBC is required as it declares climate impacts calculated according to the principle of instantaneous oxidation. GWP-IOBC is also referred to as GWP-GHG in context to Swedish public procurement legislation.
Bibliography and Contact Information
Bibliography
- ISO 14025:2010 Environmental labels and declarations - Type III environmental declarations - Principles and procedures.
- ISO 14044:2006 Environmental management - Life cycle assessment - Requirements and guidelines.
- EN 15804:2012+A2:2019 Environmental product declaration - Core rules for the product category of construction products.
- ISO 21930:2017 Sustainability in buildings and civil engineering works - Core rules for environmental product declarations of construction products.
- ecoinvent v3, Allocation, cut-off by classification, Swiss Centre of Life Cycle Inventories.
- Iversen et al., (2021) EPD generator v2021.09 - Background information for EPD generator tool system verification, LCA.no AS, report number: 07.21
- Vold, M. et al. (2022) EPD generator for Building boards Background information for EPD generator application and LCA data, LCA.no report number 05.22
- NPCR Part A: Construction products and services. Ver. 2.0. March 2021, EPD-Norge.
- NPCR 010 Part B for Building Boards. Ver. 4.0, March 2022, EPD-Norge.
- Haugbølle, K., Mahdi, V., Morelli, M., & Wahedi, H. (2022). BUILD Levetidstabel. BUILD - Institut for Byggeri, by Og Miljø, 2, 978-87-563-2072-6. https://build.dk/Pages/BUILD-levetidstabel.aspx
Program operator and publisher
The Norwegian EPD Foundation
Post Box 5250 Majorstuen, 0303 Oslo, Norway
Phone: +47 977 22 020
e-mail: post@epd-norge.no
web: www.epd-norge.no
Owner of the declaration
Roth North Europe A/S
Centervej 5, 3600 Frederikssund, Denmark
Phone: +45 47 33 97 00
e-mail: sustainability@roth-northeurope.com
web: roth-northeurope.com
Author of the Life Cycle Assessment
LCA.no AS
Dokka 6A, 1671 Kråkerøy, Norway
Phone: +47 916 50 916
e-mail: post@lca.no
web: www.lca.no
Developer of EPD generator
LCA.no AS
Dokka 6A, 1671 Kråkerøy, Norway
Phone: +47 916 50 916
e-mail: post@lca.no
web: www.lca.no
ECO Platform
ECO Portal
web: www.eco-platform.org
web: ECO Portal