Inventer aV100 ALD Installation Guide
Model: aV100 ALD
Article Number: 5040-0058
Manufacturer: Inventer GmbH
Product Overview
The Inventer aV100 ALD is a ventilation component designed for air exchange in buildings. This guide provides instructions for its installation.
Visual Description: A white, louvered ventilation component labeled aV100 ALD.
Assembly Components: The product typically includes an outer grille, an inner component, a duct section, and mounting hardware (screws).
Technical Specifications & Dimensions
Wall Thickness Compatibility: The unit is designed for wall thicknesses ranging from 150 mm to 500 mm.
Duct Opening Diameter: Ø 103 mm.
Outer Grille Dimensions: Height: 160 mm, Width: 124 mm, Depth: 55 mm.
Inner Component Diameter: 112 mm.
Installation Diagram Details: A cross-section diagram illustrating the installation of the ventilation unit within a wall. It shows dimensions for wall thickness (150-500 mm), duct length (495 mm), and clearances.
Measurement Guide (X and Y):
Outer Grille Variant | Inner Grille | X in [mm] | Y in [mm] |
---|---|---|---|
aV100 | ALD 100 | A + B + C + D | 0 |
Flex aV100 | ALD 100 | A + B + C + D | 10 |
Corner | ALD 100 | A + B + 5 | 10 |
Nordic (two-leaf masonry / clinker) | ALD 100 | A + B + 5 | UBP + 10 (with UBP base plate) |
Nordic (single-leaf masonry / WDVS) | ALD 100 | A + B + 5 | C + D - 200 (min. 30 mm) |
Nordic (single-leaf masonry / WDVS) | ALD 100 | A + B + 5 | C + D - 95 (min. 30 mm) |
Note: A, B, C, D refer to wall layer measurements. UBP refers to an optional base plate.
Installation Requirements
Tools Required for Wall Opening:
- Core drill bit: Ø 115 mm
- Angle grinder
- Saw
- Spray can (for dust suppression or sealant)
- Sealant gun
Tools Required for Mounting:
- Drill
- Drill bit: Ø 6 mm
- Sealant gun
Safety Precautions:
- ⚠️ General Warning
- ?️ Wear eye protection
- ✋ Wear hand protection
- ? Do not smoke during installation
- ? Ensure hands are clean
Airflow Direction: The system facilitates fresh air intake (Zuluftraum) and exhaust air (Abluftraum).
Installation Steps
- Prepare Wall Opening: Diagram showing tools for creating a wall opening: a core drill with a Ø 115 mm bit, an angle grinder, a saw, a spray can, and a sealant gun. Measure and mark the required hole diameter (Ø 115 mm) on the wall. Use a core drill to create the opening.
- Adjust Angle: Diagram illustrating the adjustment of a component's angle to 1-2° using a spirit level. Ensure the duct is installed with a slight downward slope (1-2°) for drainage.
- Insert Duct: Diagram showing a cylindrical component being inserted into another. Insert the duct section into the wall opening.
- Seal Opening: Diagram showing sealant application around a component in a wall opening, with a 24-hour timer indicating curing time. Apply sealant around the duct where it meets the wall to ensure an airtight seal. Allow 24 hours for curing if specified.
- Install Outer Grille: Diagram showing the outer grille being aligned vertically with a spirit level and pencil marks. Includes safety warning (⚠️) and angle indicator (0°). A list of optional part numbers is provided: 1002-0034, 1002-0046, 1508-0207, 1508-0208, 1508-0209, 1508-0210. Align the outer grille with the wall opening using a spirit level to ensure it is vertical (0°). Diagram showing a pilot hole being drilled with a Ø 6 mm bit, at a distance of 50 mm. Drill pilot holes (Ø 6 mm) as indicated, approximately 50 mm from the edge. Diagram showing the outer grille being attached to the wall opening and sealant being applied from the inside. Apply sealant to the back of the outer grille or around the opening. Diagram showing the outer grille being secured with screws. Secure the outer grille to the wall using screws.
- Install Inner Component: Diagram illustrating the attachment of the inner component with a locking mechanism. Insert the inner component into the duct from the inside. Diagram showing the inner part being slid into place, with a warning symbol (⚠️). Ensure it is correctly oriented and fits snugly. Diagram showing the final attachment of the inner part. Attach the inner component, ensuring it locks or clips into place securely.
- Final Check: Verify all components are securely attached and the installation is complete.
Important Disclaimer
This document is valid only in conjunction with the original instructions for inVENTer ventilation systems and controllers. Please read the original documentation carefully and observe all safety and warning instructions.
Company Information:
inVENTer GmbH
Ortsstraße 4a
D-07751 Löberschütz
www.inventer.de
Version: 1.0 – 09/2022
Article Number: 5040-0058