Amana Top Mount Refrigerator
Models: ARTX2019S*, ARTX2419S* | Size: 19.3 cu ft (546.51 L)
Product Dimensions
The physical dimensions for the Amana Top Mount Refrigerator (Models ARTX2019S*, ARTX2419S*) are detailed below. A visual representation shows a standard refrigerator outline with key measurement points labeled A through G.
Label | Description | Measurement |
---|---|---|
A | Overall Height | 1681.2 mm (66 3/16") |
B | Height to top of cabinet | 1662.1 mm (65 7/16") |
C | Depth with door open 90° | 1520.8 mm (59 7/8") |
D | Overall Depth | 819.2 mm (32 1/4") |
E | Cabinet Depth only | 720 mm (28 3/8") |
F | Width of cabinet | 749.3 mm (29 1/2") |
G | Door Opening Clearance | 39 mm (1 9/16") |
Reversible Doors: Yes
Electrical Requirements
⚠️ WARNING: Electrical Shock Hazard
- Ensure connection to a grounded 3-prong outlet.
- Do not remove the ground prong.
- Do not use an adapter.
- Do not use an extension cord.
Failure to comply with these instructions may result in death, fire, or electrical shock.
Before moving the refrigerator to its final location, verify the electrical connection. If the power cord is damaged, it must be replaced by the manufacturer, their service agent, or a similarly qualified person. Avoid using a cord with visible cracks or abrasion damage.
Recommended Grounding Method:
A 115 V, 60 Hz, AC-only electrical supply, fused at 15A or 20A and properly grounded, is required. It is recommended to use a dedicated circuit for the refrigerator. Utilize an outlet that cannot be switched off. Extension cords are not permitted.
NOTE: Prior to any installation, cleaning, or light bulb replacement, turn the refrigerator to the 'Off' position. Depending on the model, this may involve turning the control knob to 'Off' or pressing the down arrow on the display until a dash (-) appears. Disconnect the refrigerator from the electrical source. Once finished, reconnect to the power source and reset temperature controls as desired. Refer to the "Using the Controls" section in the Quick Start Guide for details.
Location Requirements
⚠️ WARNING: Explosion Hazard
- Keep flammable materials and vapors, such as gasoline, away from the appliance.
- Use only nonflammable cleaners.
Non-compliance with these instructions can lead to death, explosion, or fire.
IMPORTANT: This refrigerator is designed for indoor use and for use in covered indoor garages. Garage-ready compatibility may vary by model; check the freezer knob for confirmation.
Ventilation:
- Ensure 1/2" (1.25 cm) of space on each side of the refrigerator.
- Allow 1 1/2" (3.81 cm) of space between overhead cabinets and the top of the refrigerator.
- Maintain at least 1" (2.54 cm) of space between the back of the cabinet and the wall.
- If equipped with an ice maker, ensure additional space at the rear for water line connections.
Temperature and Placement:
This refrigerator is designed for locations with ambient temperatures ranging from a minimum of 55°F (13°C) to a maximum of 110°F (43°C). For optimal performance, reduced energy consumption, and superior cooling, the ideal temperature range is between 60°F (15.6°C) and 90°F (32°C). Avoid installing the refrigerator near heat sources like ovens or radiators.