Amana 30" (76.2 cm) Freestanding Electric Range
Product Model Numbers
Model | Model | Model |
---|---|---|
ACR2303MF | AER3311WA | AER5630BA |
ACR3130BA | AER5330BA | AER5823XA |
ACR4303ME | AER5523XA | AER5830VA |
ACR4303MF | AER5524XA | AER6303MF |
ACR4503SF | AER6603SF | |
ACR4530BA | AER6203MSS | |
ACR4503SF |
Product Dimensions
Diagram showing the front view of the electric range with labels A through F indicating different dimensions.
- A. 27 ¾" (70.5 cm) max. depth with handle
- B. 46⁷⁄₈" (119.1 cm) overall height (maximum) with leveling legs screwed all the way in*
- C. 36" (91.4 cm) cooktop height (maximum) with leveling legs screwed all the way in*
- D. 29 ⁷⁄₈" (75.9 cm) width
- E. 25 ⁵⁄₁₆" (64.3 cm) depth – back of range to front of cooktop**
- F. Model/serial rating plate (located on the left-side frame behind the storage drawer panel or behind the top right side of the oven door)
IMPORTANT: Range must be level after installation. Follow the instructions in the "Level Range" section. Using the cooktop as a reference for leveling the range is not recommended.
* Range can be raised approximately 1" (2.5 cm) by adjusting the leveling legs.
** Front of door and drawer may extend further forward depending on styling.
Electrical Requirements
To properly install your range, determine the type of electrical connection you will be using and follow the instructions provided.
- Range must be connected to the proper electrical voltage and frequency as specified on the model/serial number rating plate. The rating plate is located on the left-side frame behind the storage drawer panel or behind the top right side of the oven door.
- This range is manufactured with the neutral terminal connected to the cabinet. Use a 3-wire, UL Listed, 40- or 50-amp power supply cord (pigtail). If local codes do not permit a ground through the neutral, use a 4-wire power supply cord rated at 250 volts, 40 or 50 amps and investigated for use with ranges.
Range Rating*
Voltage | Voltage | Specified Rating of Power Supply Cord Kit and Circuit Protection (Amps) |
---|---|---|
120/240 Volts | 120/208 Volts | 40 or 50 ** |
8.8 – 16.5 KW | 7.8 – 12.5 KW | 50 |
16.6 – 22.5 KW | 12.6 – 18.5 KW |
* The NEC calculated load is less than the total connected load listed on the model/serial rating plate.
** If connecting to a 50-amp circuit, use a 50-amp rated cord with a kit. For 50-amp rated cord kits, use kits that specify use with a nominal 1 ³⁄₈" (34.9 mm) diameter connection opening.
A circuit breaker is recommended. ?
Cabinet Opening Dimensions
Cabinet opening dimensions shown are for 25" (64.0 cm) countertop depth, 24" (61.0 cm) base cabinet depth and 36" (91.4 cm) countertop height.
IMPORTANT: If installing a range hood or microwave hood combination above the range, follow the range hood or microwave hood combination instructions for dimensional clearances above the cooktop surface.
A freestanding range may be installed next to combustible walls with zero clearance. ?
* NOTE: 24" (61.0 cm) minimum when bottom of wood or metal cabinet is covered by not less than ¼" (0.64 cm) flame-retardant millboard covered with not less than No. 28 MSG sheet steel, 0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper.
Diagram showing cabinet opening dimensions with labels A through F.
- A. 13" (33.0 cm) maximum upper cabinet depth
- B. 30" (76.2 cm) minimum opening width
- C. For minimum clearance to top of cooktop, see NOTE*
- D. 30 ⁷⁄₈" (76.5 cm) min opening width
- E. Outlet – 8" (20.3 cm) to 22" (55.9 cm) from either cabinet, 5 ½" (14.0 cm) max. to floor
- F. Cabinet door or hinges should not extend into the cutout