WLS70 Industrial LED Strip Light (AC)
Quick Start Guide
This guide is designed to help you set up and install the WLS70 Industrial LED Strip Light (AC). For complete information on programming, performance, troubleshooting, dimensions, and accessories, please refer to the Instruction Manual at www.bannerengineering.com. Search for p/n 220753 to view the Instruction Manual. Use of this document assumes familiarity with pertinent industry standards and practices.
Models
Family | Voltage | Cascade | Color | Lighted Length (mm) | Window | Control | Connection |
---|---|---|---|---|---|---|---|
WLS70 | Z | X = Non-Cascadable C = Cascadable |
W = Daylight white | 300 = 300 mm 600 = 600 mm 900 = 900 mm 1200 = 1200 mm |
D = Diffused Window | A = 0-10 V Analog Dimming | QM |
Z=AC | Bank = 5-wire, 2m Cable QM = 5-pin Integral Mini QD |
*Cascadable models only available with QM connection.
**Models with a quick disconnect require a mating cordset. See Cordsets on p. 3.
Installing the WLS70 Industrial LED Strip Light
Step 1: Turn off power at fuse or circuit breaker box.
Step 2: Remove the light from the packaging and inspect it for damage before installing it.
Step 3: Attach the included LMBWLS70T clamp brackets to the light. Slide on gasket if desired. Refer to the instruction manual for a complete list of compatible brackets.
Step 4: Select a suitable horizontal or vertical mounting location.
Step 5: Place the light in the mounting location and mark the positions of the bracket mounting holes. The optional LMBWLS70HK bracket can be used to hang the light in conjunction with the LMBWLS70T (see Brackets on p. 3).
Step 6: Drill the holes and use appropriate screws to secure the bracket to the mounting location.
Step 7: Clamp the light onto the brackets.
Step 8: When daisy chaining multiple lights, follow steps 1 through 5 to mount additional lights. See the application note in Specifications on p. 2 for the maximum allowed lights daisy chained together and maximum allowed cable run when choosing mounting locations.
Step 9: Connect the daisy chained units together using cascade cordsets (see Cordsets on p. 3).
Step 10: Verify the supplied cascade cover is on the output connector of the last light in the chain.
Step 11: Attach cables (cabled model) or cordsets (quick-disconnect model) per the wiring diagram. Terminate wire as appropriate per application.
Installation is complete. Turn on electricity at fuse or circuit breaker box.
Wiring Diagram
Diagram | Wire | Connection | Pinout (Male) | Pinout (Female) |
---|---|---|---|---|
L - Black | Line/Hot | 1 - Purple | 1 - Purple | |
N - White | Neutral | 2 - White | 2 - White | |
- Green/Yellow | Earth ground | 3 - Yellow/Green | 3 - Yellow/Green | |
Dim (+) - Purple | 0-10 V DC analog dimming | 4 - Black | 4 - Black | |
Dim (-) - Gray | Return analog dimming | 5 - Gray | 5 - Gray |
Specifications
Supply Voltage
Nominal voltage: 120 V AC to 277 V AC, 60 Hz in North America
Nominal voltage: 100 V AC to 277 V AC, 50/60 Hz outside North America
Power factor: > 0.95 at 120 V AC and > 0.90 at 277 VAC
Total harmonic distortion (THD) < 20%
See electrical characteristics on product label
Supply Current
Lighted Length (mm) | Max Current Draw (A) at 100V AC | Typical Current Draw (A) at 120 V AC | Typical Current Draw (A) at 230 V AC | Typical Current Draw (A) at 277 V AC |
---|---|---|---|---|
300 | 0.120 | 0.080 | 0.040 | 0.040 |
600 | 0.220 | 0.165 | 0.080 | 0.070 |
900 | 0.320 | 0.240 | 0.130 | 0.110 |
1200 | 0.420 | 0.315 | 0.160 | 0.140 |
Application Notes
When connecting continuous run/cascadable lights in series, it is important not to exceed maximum current limitations of 8A. For example: the typical current draw of a 1200 mm fixture at 120 V is 0.315A. 8A / 0.315A yields a maximum of 25 fixtures cascaded together.
Two or more lights installed in parallel must maintain a 150 mm (6 inch) spacing to maintain a 50 °C operating temperature.
Emissions and Approvals
CULUS LISTED
UL/cULus E470122
Dimming
Compatible with 0-10 V analog LED dimming, dimmable to 5% intensity.
Dimming current: <1.0 mA
Supply Protection Circuitry: Protected against transient voltages.
Construction
Clear anodized aluminum housing; polycarbonate outer housing.
Mounting
Several optional mounting brackets are available (see Accessories).
Connections
Integral 5-pin 7/8" Mini-style quick disconnect (8BA/300V/2.5kV/2) or 2 m (6.5 ft) integral STOOW UL/HAR PVC cable. See Cordsets on p. 3.
Environmental Rating
IP65
LED Lifetime
When operating within specifications, output will decrease less than 30% after 50,000 hours.
Operating Temperature
Surface Mount Installation: -40 °C to +50 °C (-40°F to +122 °F)
85% at +50°C maximum relative humidity (non-condensing)
Storage Temperature
-40 °C to +70 °C (-40°F to +158 °F)
Vibration and Mechanical Shock
Vibration: 10 Hz to 55 Hz, 0.5 mm peak-to-peak amplitude per IEC 60068-2-6 (5 minute sweep, 30 minute dwell)
Shock: 15G 11 ms duration, half sine wave per IEC 60068-2-27
Impact: IK10 (IEC 60068-2-75)
Light Characteristics
CRI: 82, typical
Up to 143 lumens/watt typical at 120 V AC at 25°C (77 °F)
Model | Color | Color Temperature (CCT) | Lumens (Typical at 25 °C) | Watts at 120 V AC | Luminous Efficacy (lm/w) |
---|---|---|---|---|---|
WLS70..300. | Daylight White | 5000K (±300 K) | 1350 | 9.6 | 141 |
WLS70..600. | Daylight White | 5000K (±300 K) | 2700 | 19.8 | 136 |
WLS70..900. | Daylight White | 5000K (±300 K) | 4050 | 28.8 | 141 |
WLS70..1200. | Daylight White | 5000K (±300 K) | 5400 | 37.8 | 143 |
Dimensions
All measurements are listed in millimeters [inches], unless noted otherwise.
QD Models:
Cable Models:
QD Cascadable Models:
Model | Housing Length (L1) | Lighted Length (L2) |
---|---|---|
WLS70..300. | 369.8 | 302 |
WLS70..600. | 667.6 | 600 |
WLS70..900. | 965.3 | 898 |
WLS70..1200. | 1263 | 1196 |
Accessories
Brackets
All measurements are listed in millimeters, unless noted otherwise. Refer to the instruction manual for a complete list of compatible brackets.
LMBWLS70T
- Stainless steel
- Includes two clamp brackets for hanging or surface mount, two anti-rotation gaskets, and stainless steel hardware for securing the bracket to the light
- For use with M8 or 5/16" mounting hardware
Note: The LMBWLS70T is supplied with the light.
LMBWLS70HK
- Hanging bracket kit allows for suspended installation
- Includes two hanging bracket assemblies
- For use with bracket LMBWLS70T
Cordsets
5-Pin Threaded 7/8-in Cordsets - Single Ended
Model | Length | Style | Dimensions | Pinout (Female) |
---|---|---|---|---|
MBCCL-506 | 2 m (6.56 ft) | Straight | 1 - Purple 2 - White 3 - Yellow/Green 4 - Black 5 - Gray |
|
MBCCL-515 | 5 m (16.4 ft) |
5-Pin Threaded 7/8-in Cordsets - Double Ended
Model | Length | Style | Pinout (Male) | Pinout (Female) |
---|---|---|---|---|
MBCCL-503SS | 1 m (3.28 ft) | Female Straight/Male Straight | 1 - Purple 2 - White 3 - Yellow/Green 4 - Black 5 - Gray |
1 - Purple 2 - White 3 - Yellow/Green 4 - Black 5 - Gray |
MBCCL-506SS | 2 m (6.56 ft) | |||
MBCCL-512SS | 4 m (13.1 ft) | |||
MBCCL-520SS | 6 m (19.7 ft) |
Banner Engineering Corp. Limited Warranty
Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product.
THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE).
This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE.
Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the product is not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will void the product warranties. All specifications published in this document are subject to change. Banner reserves the right to modify product specifications or update documentation at any time. Specifications and product information in English supersede that which is provided in any other language. For the most recent version of any documentation, refer to: www.bannerengineering.com/patents.
For patent information, see www.bannerengineering.com/patents.
FCC Part 15 and CAN ICES-3 (B)/NMB-3(B)
This device complies with part 15 of the FCC Rules and CAN ICES-3 (B)/NMB-3(B). Operation is subject to the following two conditions:
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules and CAN ICES-3 (B)/NMB-3(B). These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the manufacturer.
Mexican Importer
Banner Engineering de México, S. de R.L. de C.V.
David Alfaro Siqueiros 103 Piso 2 Valle de Oriente
San Pedro Garza Garcia Nuevo León, C.P. 66269
81 8363.2714
Related Documents
![]() |
Banner Automotive Rework Bay Solutions: Vehicle Detection, Status, and Collision Avoidance Banner Engineering offers advanced solutions for automotive rework bays, enhancing efficiency and safety with vehicle detection sensors, status indication systems, and collision avoidance technology. Optimize lean workflows with smart factory integration. |
![]() |
WLF12 Pro Flexible Strip Lights for Industrial Applications | Banner Engineering Explore the WLF12 Pro, a durable and flexible multicolor LED strip light from Banner Engineering. Designed for industrial status indication, it features customizable lengths, easy M12 connections, 19 colors, 15 animations, and high-strength adhesive backing for quick installation. Ideal for AGVs and other industrial equipment. |
![]() |
Banner Engineering Recommended Products for Industrial Automation A comprehensive catalog of Banner Engineering's recommended products for industrial automation, featuring sensors, lighting and indication, safety components, and connectivity solutions. |
![]() |
Banner Engineering: Industrial Lighting and Indication Selection Guide A comprehensive selection guide for Banner Engineering's industrial LED lighting, tower lights, indicators, touch buttons, pick-to-light devices, and displays, detailing features, specifications, and communication protocols. |
![]() |
Banner Engineering BC-M12x4x-G22-HF20 High-Flex Cordsets: Specifications & Warranty Details the technical specifications, model configurations, construction, and limited warranty for Banner Engineering's BC-M12x4x-G22-HF20 High-Flex Cordsets, designed for industrial applications requiring high durability and 20 million bend cycles. |
![]() |
BC-M8x4-G24-HF20 4-pin A-Code M8 High-Flex Cordsets | Banner Engineering Discover Banner Engineering's BC-M8x4-G24-HF20 High-Flex Cordsets, featuring 20 million bend cycles, 4-pin A-code M8 connectors, and durable construction for industrial applications. View specifications and warranty details. |
![]() |
GS60 Guide Spotlight Instruction Manual - Banner Engineering Comprehensive instruction manual for the Banner Engineering GS60 Guide Spotlight, covering features, wiring, specifications, accessories, and warranty information. Includes detailed technical data and safety precautions. |
![]() |
Q90R R-GAGE® Radar Sensor Instruction Manual | Banner Engineering Comprehensive instruction manual for the Banner Q90R R-GAGE® Radar Sensor, covering product description, installation, configuration, specifications, and product support. Learn how to set up and use this industrial radar sensor. |