#Chemicalfreeworld Environmentally Friendly
Air purification and Surface Disinfection Solutions
User Guide
MAC500s
Multi Air Cleaner
IMPORTANT SAFETY INSTRUCTIONS
REED AND SAVE THESE INSTRUCTIONS
WARNING!!!
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS OBSERVE THE FOLLOWING:
- Before opening the appliance, it must be switched off, and unplugged from the socket to prevent being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag. When the device is open, there is a risk of radiation from the UV-C light. This can lead to painful corneal inflammation (conjunctivitis).
- When servicing or replacement of a component make sure to reinstall or remount all safety requirements as previously installed.
- Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.
- Skin or eye damage may result from directly viewing the light produced by the lamp in this apparatus. Always disconnect power before relamping or servicing. Replace Lamp With Lamp Model No. J205-1122-8W UV-OZ LL, Manufactured by JIMCO. Do not operate any appliance with a damaged cord or plug. Discard appliance or return to an authorized service facility for examination and/or repair.
- Do not run cord under carpeting. Do not cover cord with throw rugs, runners, or similar coverings. Do not route cord under furniture or appliances. Arrange cord away from traffic area and where it will not be tripped over.
- This appliance must be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric current. This appliance is equipped with a cord having a grounding wire with a grounding plug. The plug must be plugged into an outlet that is properly installed and grounded. Improper grounding can result in a risk of electric shock.
- Place the machine on a solid surface. Preferably elevated for the best effect.
- For wall mounting, follow instructions on page 6-10.
- Never immerse the appliance in water.
- For indoor use only.
AVERTISSEMENT !!
POUR RÉDUIRE LES RISQUES D'INCENDIE, DE CHOC ÉLECTRIQUE OU DE BLESSURE, RESPECTEZ LES CONSIGNES SUIVANTES :
- Avant d'ouvrir l'appareil, il faut l'éteindre et le débrancher de la prise de courant pour éviter qu'il ne soit mis en marche accidentellement. Lorsque le dispositif de déconnexion ne peut pas être verrouillé, fixer solidement un dispositif d'avertissement bien visible, tel qu'une étiquette. Lorsque l'appareil est ouvert, il y a un risque de rayonnement de la lumière UV-C. Cela peut entraîner une inflammation douloureuse de la cornée (conjonctivite).
- Lors de l'entretien ou du remplacement d'un composant, veiller à réinstaller ou à remonter tous les dispositifs de sécurité tels qu'ils ont été installés précédemment.
- N'utilisez cet appareil que de la manière prévue par le fabricant. Si vous avez des questions, contactez le fabricant.
- Les dommages à la peau ou aux yeux peuvent résulter de l'observation directe de la lumière produite par la lampe de cet appareil. Débranchez toujours l'appareil avant de le rallumer ou de le réparer. Remplacez la lampe par la lampe n° J205-1122-8W UV-OZ LL, fabriquée par JIMCO. Ne faites pas fonctionner un appareil dont le cordon ou la fiche est endommagé. Mettez l'appareil au rebut ou retournez-le dans un centre de service agréé pour examen et/ou réparation.
- Ne faites pas passer le cordon sous la moquette et ne le recouvrez pas d'un tapis, d'un tapis de sol ou d'un autre revêtement similaire. Ne pas faire passer le cordon sous les meubles ou les appareils. Placez le cordon à l'écart des zones de circulation et à un endroit où il ne risque pas de causer de chutes.
- Cet appareil doit être mis à la terre. En cas de court-circuit électrique, la mise à la terre réduit le risque de choc électrique en fournissant un fil de sortie pour le courant électrique. Cet appareil est équipé d'un câble comportant un fil de mise à la terre et une fiche de mise à la terre. La fiche doit être branchée dans une prise correctement installée et mise à la terre. Une mise à la terre incorrecte peut entraîner un risque d'électrocution.
- Placez la machine sur une surface solide. De préférence surélevée pour un effet optimal.
- Pour un montage mural, suivez les instructions de la page 6-10.
- Ne jamais immerger l'appareil dans l'eau.
- Pour un usage intérieur uniquement.
Description
MAC500s produces UV-C light under controlled conditions. Different UV-C wavelengths have different properties. The MAC500s uses two wavelengths. One is a powerful sterilizer when it is in direct contact with pathogens and the other wavelength uses the available oxygen (O2) to naturally produce a low level of ozone (O3). The low level of ozone recreates the fresh air from outside in nature inside your home or office. The ozone dynamically attacks dangerous airborne pathogens in the air you breathe and can deactivate airborne virus.
This method is called photolytic oxidation and JIMCO A/S has won EU environmental Award for Developing a Cleaner Technology.
The purpose with the MAC500s is to purify the air you breathe.
Intended use
The MAC500s is intended to be used 24 hours a day. The recommended room size is 60 m³ (24 m² with a ceiling height of 2.5 m). The unit should not be operated while situated on the floor but should be placed as high as possible for maximum efficiency.
The unit must not be operated without cover.
When more units are placed in a room they must be placed as far from each other as possible to get an even distribution of the area they cover.
Function
Photolytic oxidation makes a cold incineration with airborne pathogens and organic particles such as fungal spores, virus, bacteria, yeast, ethylene gasses, nicotine etc. The process is environmentally friendly and the cold incineration will reduce the airborne pathogens and organic particles significantly.
The MAC500s reduce ethylen gasses, bacteria and fungal spores, which will extend the shelf life of food, fruit and vegetables.
The MAC500s will effectively reduce odor from rooms deposited in walls, carpets, textiles, furnitures etc.
Technical Data MAC500s
Parameter | Value | Parameter | Value |
---|---|---|---|
Room area | 60 m³ | Power consumption | 23 w |
UV lamps | 1x8 W | Height | 3.8 inch (96 mm) |
Operating hours | 8000 | Length | 15.8 inch (400 mm) |
Voltage | 120V | Width | 3.7 inch (93 mm) |
Lifetime of the lamps
The lifetime of the JIMCO special lamp is around 8,000 operating hours. After the expiry of 8,000 operating hours, the efficiency of the lamp will be reduced, which means if the air is not purified as usual then the lamp should be replaced.
8,000 operating hours equals approximately a year of operation. If the effect of the device drops before the end of 8,000 operating hours, you should check if the JIMCO Special lamp is dirty with e.g. dust particles. If this is the case, follow the cleaning instructions.
Maintenance
To maintain the optimal performance of the MAC500s, JIMCO recommends for regular use to clean the lamp and fan about every 3 months. When used in heavily soiled/dusty rooms, this should be done more often.
Cleaning the appliance:
- Turn off the appliance and then unplug it from the socket.
- Clean the outside of the appliance with a damp cloth, use a little detergent if necessary (Follow the instructions of the detergent).
- Clean the lamp and fan with a clean and soft cloth, use a little ethyl alcohol if necessary.
- Note the date of cleaning.
Operation Instructions
- Switch the appliance on and off with the On / Off switch [1]. The red lamp lights to indicate that the appliance is now switched on.
- When there are 500 operating hours left, the On / Off lamp will start to flash.
- When the appliance has been in operation for more than 8000 hours, all 3 red lights start flashing and an acoustic signal is heard around every 30 minutes. The lamp must now be replaced.
- When the lamp is replaced, Reset the Timer by holding down the Reset button [2] for more than 5 seconds. 5 quick beeps are heard, and the unit is ready for use again.
Warranty Regulations
On the MAC500s, JIMCO A/S provides a 24-month warranty. The guarantee period is 12 months. The warranty is calculated from the date of sale from your JIMCO dealer. To provide this, a receipt must be kept. Within the stated warranty period, JIMCO A/S will cover, without charge, every defect that is subject to material or manufacturing defects and, at your option, provides warranty repair or replacement of the MAC500s.
Prerequisite for the guarantee benefit is that the appliance is used according to its purpose and in accordance with the operating instructions. Excluded from the warranty are damages caused by improper use, wear or interference on the part of the owner or third parties. The warranty does not cover consumables – e.g. the lamp – or wear objects like the fan, which only negatively affect the value or usefulness of the MAC500s.
Installation instruction
In the package
- 1x MAC500s (Multi Air Cleaner)
- 2x Screws (found in the bottom of the MAC500s)
- 2x DIN Rail Brackets (in the box)
- 1x DIN Rail (in the box)
General Placement
- Find a suitable place for your MAC500s. Note: We recommend placing the MAC500s at least 200 mm away from any side obstacles on both sides to ensure proper inlet and outlet air flow.
- Connect the instrument to a suitable plug socket.
- Place the MAC500s on a solid surface, e.g., on a shelf.
- To get the best effect, we recommend placing the MAC500s as high as possible, e.g., 5.9 feet (approx. 1.8 meters).
For wall mounting, see the mount instruction on pages 5-11.
Wall mount your MAC500s
See drawings on pages 6-11.
- Find a suitable place for your MAC500s. Note: We recommend placing the MAC500s at least 200 mm away from any side obstacles on both sides to ensure inlet and outlet air. It must be installed vertically.
- Place the DIN rail on the wall and level it. Diagram shows a DIN rail being leveled with a spirit level, with markings for screw holes.
- Mark the holes with a pencil (on each side of the rail). Diagram shows pencil marks on the wall corresponding to the rail's mounting points.
- Drill the holes and insert anchors (if needed). Diagram shows drilling into the wall and inserting wall anchors.
- Mount the DIN rail with suitable screws/anchors/plugs for the surface. Diagram shows the DIN rail securely attached to the wall.
- Mount the DIN rail brackets on the back side of the MAC500s with the screws/anchors/plugs. Diagram shows the MAC500s unit with brackets being attached to its rear.
- Note 1: The harder you tighten the screws, the more securely the MAC500s will be mounted on the DIN rail.
- Note 2: You can choose individually on which side you want the outlet air from the MAC500s; outlet air is on the same side as the operation buttons.
- Note 3: By turning the DIN rail brackets 180° (degree), you can choose individually on which side you want the outlet air.
- Note 4: Hooks on the DIN rail brackets shall always be placed at the top according to the choice of the outlet air.
- Mount MAC500s on the mounted DIN rail on the wall. Make sure to attach the hooks on the DIN rail brackets first to the DIN rail and then push the MAC500s towards the wall. Diagram shows the MAC500s unit being slid onto the wall-mounted DIN rail. A "CLICK!" sound is indicated.
- Note 5: Make sure that you hear "click".
Lamp change:
Follow these steps to change the lamp:
- Step 1: Disconnect the power to the MAC500s by unplugging it from the wall socket [2]. Diagram shows the unit unplugged from the wall.
- Step 2: Remove the six screws [3] and remove the cover and guards [4]. Diagram shows screws being removed from the unit's rear/sides and the cover being lifted off.
- Step 3: Untighten the screws on the lamp holders [5] and disconnect the lamp connector [6]. Diagram shows screws on lamp holders being loosened and a connector being unplugged from the lamp.
- Step 4: Pull the lamp [7] out of the lamp holders. Diagram shows the old lamp being removed.
- Step 5: Insert the new lamp into the lamp holders and connect the lamp connector. Diagram shows a new lamp being inserted and connected.
- Step 6: Slightly tighten the screws [5]. DO NOT USE EXCESSIVE FORCE. Diagram shows screws being tightened on the new lamp holders.
- Step 7: Attach the cover and guards. Reinstall the screws [3 and 4]. Diagram shows the cover being replaced and screws being reinserted.
STATEMENT OF COMPLIANCE
The undersigned, who represent the manufacturer mentioned below:
- Manufacturer: Jimco A/S
- Address: Mjølbyvej 7 – DK-5900 Rudkøbing
- Declare that
- Product identification: MAC500S
- is manufactured in compliance with the following EU directives:
- 2014/35/EU: Low Voltage Directive (LVD)
- 2014/30/EU: Electromagnetic Compatibility (EMC) Directive
- And that standards and/or technical specifications mentioned below.
- Year when CE label was affixed: 1999
Identification of signer: Jimmy Larsen
Date: 18-05-2021
References to standards and/or technical specifications which are obligatory for this "Statement of Compliance" or parts thereof:
No. | Title | Version | Parts |
---|---|---|---|
EN60204-1 | Machinery Safety – Electrical material on machinery | 2 | |
EN IEC 55014-1 | Electromagnetic compatibility- Requirements for household appliances and similar products | Part 1: Emission |
Other technical solutions, where detailed information is included in the technical documentation or the technical dossier for the construction.
Contact
Producer: JIMCO A/S - Denmark
Mjølbyvej 7 – DK-5900 Rudkøbing
+45 6251 5456