JIMCO MAC500s Multi Air Cleaner

User Guide & Installation Instructions

Product Overview

The MAC500s is a Multi Air Cleaner designed by JIMCO, utilizing UV-C light and ozone (O3) technology to purify indoor air. It employs photolytic oxidation, a process that naturally recreates fresh air by breaking down airborne pathogens and organic particles.

Description of the Unit: The MAC500s is a sleek, rectangular air purification unit with a grey front panel and perforated side panels, featuring control buttons on the front.

JIMCO A/S has received an EU environmental award for developing this cleaner technology.

Intended Use and Function

Intended Use

The MAC500s is designed for continuous 24-hour operation. The recommended room size is 60 m³ (equivalent to 24 m² with a 2.5-meter ceiling height). For optimal efficiency, the unit should be placed as high as possible and not on the floor. If multiple units are used in a room, they should be spaced apart to ensure even air distribution.

The unit must not be operated without its cover.

Function

The MAC500s utilizes photolytic oxidation, a process that acts as a cold incineration for airborne pathogens and organic particles such as fungal spores, viruses, bacteria, yeast, ethylene gases, and nicotine. This environmentally friendly process significantly reduces airborne contaminants.

The MAC500s is effective in reducing ethylene gases, bacteria, and fungal spores, which helps extend the shelf life of food, fruits, and vegetables. It also effectively reduces odors originating from walls, carpets, textiles, and furniture.

Technical Data MAC500s

Room area: 60 m³ Power consumption: 23 W
UV lamps: 1x8 W Height: 3.8 inch (96 mm)
Operating hours: 8000 Length: 15.8 inch (400 mm)
Voltage: 120V Width: 3.7 inch (93 mm)

Important Safety Instructions

WARNING!!!

To reduce the risk of fire, electric shock, or injury to persons, observe the following:

Operation and Maintenance

Lifetime of the Lamps

The JIMCO special lamp has a lifetime of approximately 8,000 operating hours. After this period, the lamp's efficiency decreases, and it should be replaced if the air is not being purified as effectively. 8,000 operating hours is roughly equivalent to one year of operation. If the device's effectiveness diminishes before 8,000 hours, check if the JIMCO Special lamp is dirty (e.g., with dust particles) and follow the cleaning instructions.

Maintenance

To maintain optimal performance, JIMCO recommends cleaning the lamp and fan approximately every 3 months for regular use. In heavily soiled or dusty rooms, cleaning should be performed more frequently.

Cleaning the Appliance:

  1. Turn off the appliance and unplug it from the socket.
  2. Clean the exterior with a damp cloth, using a little detergent if necessary (follow detergent instructions).
  3. Clean the lamp and fan with a clean, soft cloth, using a little ethyl alcohol if necessary.
  4. Note the date of cleaning.

Operation Instructions

Control Panel Diagram: The front panel features an ON/OFF button (1) and a RESET button (2). Indicator lights signal the unit's status.

Installation Instructions

In the Package

The MAC500s package includes:

Package Contents Illustration: An illustration shows the air cleaner unit, screws, DIN rail brackets, and a DIN rail.

Standard Installation

  1. Find a suitable location for your MAC500s.
  2. Connect the unit to a suitable plug socket.
  3. Place the MAC500s on a solid surface, such as a shelf.
  4. For best results, place the MAC500s as high as possible, approximately 5.9 feet (1.8 meters) from the floor.

For wall mounting, refer to the specific instructions on pages 6-11.

Wall Mounting Instructions

Note: Ensure at least 200 mm (approx. 8 inches) of clearance on both sides of the MAC500s for proper inlet and outlet air flow. The unit must be installed vertically.

  1. Find a suitable place for your MAC500s.
  2. Place the DIN rail on the wall and ensure it is level.
  3. Mark the hole positions on the wall using a pencil (on each side of the rail).
  4. Drill the holes and insert anchors if necessary.
  5. Mount the DIN rail to the wall using appropriate screws, anchors, or plugs for the surface.
  6. Mount the DIN rail brackets onto the back of the MAC500s using screws or anchors.
  7. Note 1: The tightness of the screws affects how securely the MAC500s is mounted on the DIN rail.
  8. Note 2 & 3: The orientation of the DIN rail brackets (by turning them 180°) determines on which side the outlet air will be directed. The outlet air is on the same side as the operation buttons.
  9. Note 4: The hooks on the DIN rail brackets should always be placed at the top, according to the chosen outlet air direction.
  10. Mount the MAC500s onto the installed DIN rail. First, attach the hooks on the DIN rail brackets to the DIN rail, then push the MAC500s towards the wall.
  11. Note 5: Ensure you hear a "click" to confirm the unit is securely attached.

Wall Mounting Diagrams: Detailed illustrations show the process of attaching the DIN rail, mounting brackets to the unit, and securing the unit to the rail.

General Installation Illustration: An image depicts the MAC500s unit plugged into a wall socket and placed on a table with a lamp, illustrating typical placement.

Lamp Replacement

Follow these steps to replace the lamp:

  1. Step 1: Disconnect the power to the MAC500s by unplugging it from the wall socket.
  2. Step 2: Remove the four screws securing the cover and then remove the cover.
  3. Step 3: Lift the old lamp out of its lamp clips (Clip A and Clip B).
  4. Step 4: Gently pull the old lamp out of its socket.
  5. Step 5: Insert the new lamp into the socket.
  6. Step 6: Push the new lamp down into Lamp Clip B and Lamp Clip A.
  7. Step 7: Reattach the cover and install the four screws to secure it.

Lamp Change Diagrams: Step-by-step illustrations guide the user through the lamp replacement process.

Statement of Compliance

The undersigned, representing the manufacturer, Jimco A/S, declares that the product identification MAC500S is manufactured in compliance with the following EU directives:

The CE label was affixed in 1999. The product complies with harmonized standards including EN60204-1 (Machinery Safety - Electrical material on machinery) and EN IEC 55014-1 (Electromagnetic compatibility - Requirements for household appliances and similar products - Part 1: Emission).

Compliance Document Image: A scanned image shows the signed Statement of Compliance, identifying Jimmy Larsen and dated 18-05-2021.

Contact Information

Producer: JIMCO A/S - Denmark

Address: Mjølbyvej 7 – DK-5900 Rudkøbing

Phone: +45 6251 5456

Website: www.jimco.dk

Email: jimco@jimco.dk

VAT No.: DK 2500 0374

Lamp Switch: (Information regarding lamp switch functionality is not detailed in the provided text, only a heading is present.)

JIMCO A/S | Mjølbyvej 7 | DK-5900 Rudkøbing | Phone: +45 6251 5456 | E-mail: jimco@jimco.dk | www.jimco.dk

Always stay safe.

Models: MAC500s Multi Air Cleaner, MAC500s, Multi, MAC500s Air Cleaner, MAC500s Cleaner

File Info : application/pdf, 14 Pages, 921.44KB

PDF preview unavailable. Download the PDF instead.

63d6a7b4-aa4c-465e-9e77-426a1e023b8d

References

Microsoft PowerPoint for Microsoft 365

Related Documents

Preview JIMCO MAC500s Multi Air Cleaner User Guide and Installation Manual
Comprehensive user guide for the JIMCO MAC500s Multi Air Cleaner, detailing its UV-C and ozone technology for air purification, installation, operation, maintenance, and safety instructions.