Mitsubishi Electric NF125-LGV 3P 56-80A Material Fact Sheet
MITSUBISHI ELECTRIC EUROPE B.V.
Industrial Automation
Mitsubishi-Electric-Platz 1, 40882 Ratingen, Deutschland
Telefon: +49 (0) 2102 486-0 | Fax: +49 (0) 2102 486-1120
Website: https://emea.mitsubishielectric.com/fa
General Data
Product Hierarchy: FA-MCCB: Moulded-Case Circuit Breaker
Series: WS-V SERIES - MCCB
Type: NF-L TYPE (HIGH-PERFORMANCE)
Frame Size: 125
Rated Current (A): 56-80
Current Type: AC/DC
Number of Poles: 3
Rated Voltage (V): 690
Breaking Capacity at 400V (kA): 50/50
Compliant with Standard(s): EN 60947-2, IEC 60947-2
Cycles with Rated Current: 30000
Cycles without Rated Current: 50000
Automatic Tripping Device: THERMAL-MAGNETIC
Product Dimensions & Weight
Width (mm): 105
Height (mm): 165
Depth (mm): 92
Weight (kg): 1.6
Logistic Dimensions & Gross Weight
Length (cm): 17.0
Width (cm): 13.0
Height (cm): 10.5
Gross Weight (kg): 2.321
Volume (cdm): 1.724
Stock Data
Planned Delivery Time (Days): 120
Life Cycle
Sales Start: 06.11.2012
Predecessor: WS-V SERIES - MCCB
Additional Product Information
Binding Tariff Information: DEBTI-20365/24-1
BTI validity date: 25.09.2027
Battery included: NO
Export Data
Commodity Code: 85362010
Country of Origin: Japan (JP)
Environmental Compliance
REACH Compliance: YES
RoHS Compliance: COMPLIANT
WEEE Compliance: COMPLIANT
Conformity
CE Marking: COMPLIANT
UL/cUL: NON-COMPLIANT
EAC: NON-COMPLIANT
Shipping Approvals: LR, DNV-GL, BV, ABS, CCS
UKCA: COMPLIANT
Documentation & Media Data
Manuals: Link
Certificates: Link
CAD Data: Link
Compatible Products
Mechanical Options
Material Code | Description / Price List Text / Classification |
---|---|
225426 | V-AD3S: Variable-depth handle Adjustment Unit. V-05, V-1,V-2; approx. 300mm |
235194 | V-AD5S: Variable-depth handle Adjustment Unit. V-05, V-1,V-2; approx. 500mm |
250427 | F-2SVUL LF DR: Op. Type F. OFF Pos. lock, RESET Pos. open, ON up, NF/NV250-CVU/SVU/HVU 3P |
267210 | AL-05SV: Alarm switch. 1CO; Flying lead; Left or Right hand fitting |
267212 | AL-05SVLS: Alarm switch. 1CO; Terminal block; Left hand fitting |
267213 | AL-05SVLSB: Alarm switch. 1CO; Terminal block; Left hand fitting |
267226 | AL-05SVRS: Alarm switch. 1CO; Terminal block; 3P; Right hand fitting |
267228 | ALAX-05SV: Alarm+Auxiliary switch. 1CO, Flying lead, Left or Right hand fitting |
267230 | ALAX-05SVLS: Alarm+Auxiliary switch. 1CO, Terminal block, Left hand fitting |
267234 | ALAX-05SVRS: Alarm+Auxiliary switch. 1CO, Terminal block, 3P, Right hand fitting |
267236 | AX-05SV: Auxiliary switch. 1CO, Flying lead, Left or Right hand fitting; For 30 to 250A |
267238 | AX-05SVLS: Auxiliary switch. 1CO, Terminal block, Left hand fitting; For 30 to 250A |
267242 | AX-05SVRS: Auxiliary switch. 1CO, Terminal block, 3P, Right hand fitting; For 30 to 250A |
267246 | AX2-05SVLS: Auxiliary switch. 2CO; Terminal block, Left hand fitting; For 30 to 250A |
267249 | BAF-2SV: Front-side insulating barrier, for frame size 125-250A |
267259 | BTC-2SV3: Rear terminal cover. NF125,160,250-xxx 2 or 3P (W105) |
267359 | F-2SV LF DF: Op. Type F. OFF Pos. lock, OFF Pos. open, ON up, NF125,160,250 W105 2,3,4P |
267360 | F-2SV LF DF Y: Op. Type F. OFF Pos. lock, OFF Pos. open, ON L,NF125,160,250 W105 2,3,4P |
267361 | F-2SV LF DF Z: Op. Type F. OFF Pos. lock, OFF Pos. open, ON R,NF125,160,250 W105 2,3,4P |
267362 | F-2SV LF DR: Op. Type F. OFF Pos. lock, RESET Pos. open, ON up, NF125,160,250 W105 2,3,4P |
267363 | F-2SV LF DRY: Op. Type F. OFF Pos. lock, RESET Pos. open, ON L, NF125,160,250 W105 2,3,4P |
267364 | F-2SV LF DR Z: Op. Type F. OFF Pos. lock, RESET Pos. open, ON R,NF125,160,250 W105 2,3,4P |
267365 | F-2SV LN DF: Op. Type F. ON/OFF Pos. lock, OFF Pos. open, ON up, NF125,160,250 W105 2,3,4P |
267371 | F-2SVE LF DF: Op. Type F Emerg. OFF Pos-lock, OFF Pos-open, ON up, NF125,160,250 W105 2,3,4P |
267372 | F-2SVE LF DF Y: Op. Type F Emerg. OFF Pos-lock, OFF Pos-open, ON L,NF125,160,250 W105 2,3,4P |
267373 | F-2SVE LF DF Z: Op. Type F Emerg. OFF Pos-lock, OFF Pos-open, ON R, NF125,160,250 W105 2,3,4P |
267374 | F-2SVE LF DR: Op. Type F Emerg. OFF Pos-lock, RESET Pos-open, ON up, NF125,160,250 W105 2,3,4P |
267375 | F-2SVE LF DR Y: Op. Type F Emerg. OFF Pos-lock, RESET Pos-open, ON L, NF125,160,250 W105 2,3,4P |
267376 | F-2SVE LF DR Z: Op. Type F Emerg. OFF Pos-lock, RESET Pos-open, ON R, NF125,160,250 W105 2,3,4P |
267393 | FT-2SV2: Front connection screw terminal -EU Standard. For W105 2-pole. |
267396 | HLF-05SV: Handle lock device removable type. OFF lock. |
267397 | HLN-05SV: Handle lock device removable type. ON lock. |
267400 | HLS-2SV: Handle lock device fix type. OFF lock. For W105. |
267402 | MDSAD240-NF2SVE: Electrical operation device. Motor AC 100-240V / DC 100-250V for NF W105 |
267407 | MDSD024-NF2SVE: Electrical operation device. Motor DC 24V for NF W105 |
267411 | MDSD060-NF2SVE: Electrical operation device. Motor DC 48-60V for NF W105 |
267415 | MDSPSAD240-SV: Power supply module for MDS. AC100-240V / DC100-250V |
267416 | MDSPSD024-SV: Power supply module for MDS. DC24V |
267417 | MDSPSD060-SV: Power supply module for MDS. DC48-60V |
267418 | MI-05SV3: Mechanical interlock. For W75, W90 und W105; 2 und 3 poles. Panel mounting. |
267425 | MI-2SVFB3: Mechanical interlock. For W105; 3 poles. Breaker mounting. |
267435 | PMD-2SV2: Base of Plug-In kit without PLT, Safety Device. (W105, 2P) |
267449 | PMDN-2SV2: Plug-In kit without PLT, Safety Device. (W105, 2P) |
267463 | PMN-2SV2: Connector kit on breaker for Plug in connection. (W105, 2P) |
267474 | PTC-2SV3: Terminal Cover for Plug-In. (W90, 2P or 3P) |
267478 | SHTA048-05SVR: Shunt trip. AC 24-48V, R hand fitting, for W75, 90, 105. Flying lead. |
267479 | SHTA048-05SVRS: Shunt trip. AC 24-48V, R hand fitting, for W75, 90, 105. Terminal block. |
267483 | SHTA240-05SVR: Shunt trip. AC 100-240V, R hand fitting, for W75, 90, 105. Flying lead. |
267484 | SHTA240-05SVRS: Shunt trip. AC 100-240V, R hand fitting, for W75, 90, 105. Terminal block. |
267488 | SHTA550-05SVR: Shunt trip. AC 380-550V, R hand fitting, for W75, 90, 105. Flying lead. |
267489 | SHTA550-05SVRS: Shunt trip. AC 380-550V, R hand fitting, for W75, 90, 105. Terminal block. |
267493 | SHTD012-05SVR: Shunt trip. DC 12V, R hand fitting, for W75, 90, 105. Flying lead. |
267494 | SHTD012-05SVRS: Shunt trip. DC 12V, R hand fitting, for W75, 90, 105. Terminal block. |
267498 | SHTD036-05SVR: Shunt trip. DC 24-36V, R hand fitting, for W75, 90, 105. Flying lead. |
267499 | SHTD036-05SVRS: Shunt trip. DC 24-36V, R hand fitting, for W75, 90, 105. Terminal block. |
267503 | SHTD048-05SVR: Shunt trip. DC 36-48V, R hand fitting, for W75, 90, 105. Flying lead. |
267504 | SHTD048-05SVRS: Shunt trip. DC 36-48V, R hand fitting, for W75, 90, 105. Terminal block. |
267508 | SHTD125-05SVR: Shunt trip. DC 100-125V, R hand fitting, for W75, 90, 105. Flying lead. |
267509 | SHTD125-05SVRS: Shunt trip. DC 100-125V, R hand fitting, for W75, 90, 105. Terminal block. |
267513 | SHTD250-05SVR: Shunt trip. DC 220-250V, R hand fitting, for W75, 90, 105. Flying lead. |
267514 | SHTD250-05SVRS: Shunt trip. DC 220-250V, R hand fitting, for W75, 90, 105. Terminal block. |
267524 | SL-2SV4L: Solderless terminal. 14 - 95mm², for W105 4-polig. |
267525 | SL-2SV4G: Solderless terminal. 70 - 125mm², for W105 4-polig. |
267539 | ST-2SV2: Rear connection. For NF-SV W105 2-pole. |
267548 | TCL-2SV3: Terminal cover - large. For W105 3-pole up to 200A max 100mm². |
267557 | TCS-2SV3: Terminal cover - small. For W105 3-pole. |
267565 | TTC-2SV3: Terminal cover - transparent. For W105 3-pole. |
267599 | UVTSA250-05SVR: Under voltage trip. AC 200-250V, Instantaneous, Synch, Right, Flying lead. |
267600 | UVTSA250-05SVRS: Undervoltage Tripping Device; AC 200-250V;30 to 250A frames; Right pole; with SLT |
267604 | UVTSA480-05SVR: Under voltage trip. AC 380-480V, Instantaneous, Synch, Right, Flying lead. |
267605 | UVTSA480-05SVRS: Under voltage trip. AC 380-480V, Instantaneous, Synch, Right, Terminal. |
267609 | UVTSA600-05SVR: Under voltage trip. AC 500-600V, Instantaneous, Synch, Right, Flying lead. |
267610 | UVTSA600-05SVRS: Under voltage trip. AC 500-600V, Instantaneous, Synch, Right, Terminal. |
267614 | UVTSAD024-05SVR: Under voltage trip. AC/DC 24V, Instantaneous, Synch, Right, Flying lead. |
267615 | UVTSAD024-05SVRS: Under voltage trip. AC/DC 24V, Instantaneous, Synch, Right, Terminal. |
267619 | UVTSAD048-05SVR: Under voltage trip. AC/DC 48V, Instantaneous, Synch, Right, Flying lead. |
267620 | UVTSAD048-05SVRS: Under voltage trip. AC/DC 48V, Instantaneous, Synch, Right, Terminal. |
267624 | UVTSAD130-05SVR: Under voltage trip. AC/DC 100-130V, Instantaneous, Synch, Right, Flying lead. |
267625 | UVTSAD130-05SVRS: Under voltage trip. AC/DC 100-130V, Instantaneous, Synch, Right, Terminal. |
267689 | UVTSA048-05SVRU05: Under voltage trip. AC 24/48V, 0, 1/0,3/0,5 s, Synch, Right, Flying lead. |
267690 | UVTSA048-05SVRSU05: Under voltage trip. AC 24/48V, 0, 1/0,3/0,5 s, Synch, Right, Terminal. |
267694 | UVTSA450-05SVRU05: Under voltage trip. AC 120/240/450V, 0, 1/0,3/0,5 s, Synch, Right, Flying lead. |
267695 | UVTSA450-05SVRSU05: Under voltage trip. AC 120/240/450V, 0, 1/0,3/0,5 s, Synch, Right, Terminal. |
267709 | UVTSD048-05SVRU05: Under voltage trip. DC 24/48V, 0, 1/0,3/0,5 s, Synch, Right, Flying lead. |
267710 | UVTSD048-05SVRSU05: Under voltage trip. DC 24/48V, 0,1/0,3/0,5 s, Synch, Right, Terminal. |
267724 | UVTSA450-05SVRU30: Under voltage trip. AC 120/240/450V, 0,5/1,0/3,0 s, Synch, Right, Flying lead. |
267725 | UVTSA450-05SVRSU30: Under voltage trip. AC 120/240/450V, 0,5/1,0/3,0 s, Synch, Right, Terminal. |
267755 | V-2SV: V-handle. For 3 and 4-pole Breaker NF/DSN 125AF, 160AF, 250AF. Handle black. |
267756 | V-2SVE: V-handle. For 3 and 4-pole Breaker NF/DSN 125AF, 160AF, 250AF. Handle red/yellow |
267761 | LC-05SV: Lock cover |
403223 | AX2-05SVL: Auxiliary switch. 2CO; Flying lead; Left hand fitting; For 30 to 250A |
403224 | AX2-05SVR: Auxiliary switch. 2CO; Flying lead; right hand fitting; For 30 to 250A |
602591 | AX2-05SVLB: Auxiliary switch.2CO; Flying lead; Left pole; For 30 to 250A; Minute load switch |
602612 | AX2-05SVRB: Auxiliary switch.2CO; Flying lead; Right pole; For 30 to 250A; Minute load switch |