Mitsubishi Electric NF250-LGV 3P 125-160A Moulded-Case Circuit Breaker (MCCB) - Material Fact Sheet

This document provides detailed information regarding the Mitsubishi Electric NF250-LGV 3P 125-160A Moulded-Case Circuit Breaker (MCCB).

General Data

General Data
Product HierarchyIAN10201
MCCB
W5-V 1 - NF Body
Ext. Material Group10 STANDARD ITEM
ABC IndicatorB (Limited Availability from Stock)
e-shophttps://mitsubishi-electric-eshop.mee.com/mee/FA_IA/EUR/en/p/000000000000403223
FA-MCCB: Moulded-Case Circuit Breaker
SeriesW5-V SERIES - MCCB
TypeNF-L TYPE (HIGH-PERFORMANCE)
Frame Size250
Rated Current (A)125-160
Current TypeAC/DC
Number of Poles3
Rated Voltage (V)690
Breaking Capacity at 400V (kA)50/50
Compliant with Standard(s)EN 60947-2
Compliant with Standard(s) (2)IEC 60947-2
Cycles with Rated Current10000
Cycles without Rated Current25000
Automatic Tripping DeviceTHERMAL-MAGNETIC

Product Dimensions & Weight

Product Dimensions & Weight
Width (mm)105
Height (mm)165
Depth (mm)92
Weight (kg)1,6

Logistic Dimensions & Gross Weight

Logistic Dimensions & Gross Weight
Length (cm)17,0
Width (cm)13,0
Height (cm)10,5
Gross Weight (kg)1,746
Volume (cdm)2,321

Stock Data

Stock Data
Planned Delivery Time (Days)108

Life Cycle

Life Cycle
Sales Start06.11.2012
Predecessor212124 / NF250-SGW 3P RT 125-160A W

Additional Product Information

Additional Product Information
Binding Tariff InformationDEBTI-20365/24-1
BTI validity date25.09.2027
Battery includedNO

Export Data

Export Data
Commodity Code85362010
Legal Control (Dual Use List)Not Listed
Country of OriginJapan (JP)
Preference Status (Supplier Declaration)Non EU
REACH Limit ExceededYES
REACH Substance CAS Number119344-B
Dangerous Goods ClassNO
Dangerous Goods IdentifierNO
RoHS ComplianceCOMPLIANT
WEEEB2B

Conformity

CECOMPLIANT
UL/cULNON-COMPLIANT
EACNON-COMPLIANT
Shipping ApprovalsLR, DNV-GL, BV, ABS, CCS
UKCACOMPLIANT

Documentation & Media Data

Documentation & Media Data
Manual URL Indicatorhttps://emex.mitsubishielectric.com/fs/advanced-search?ct=document&doccats=bb6ee2fc2bd50f94&q=NF250-LGV%203P%20125-160A&doc-lang=en
Certificates URL Indicatorhttps://emex.mitsubishielectric.com/fs/advanced-search?ct=document&doccats=mt8050e01408c11c10&q=NF250-LGV%203P%20125-160A&doc-lang=en
CAD URL Indicatorhttps://emex.mitsubishielectric.com/fs/advanced-search?ct=document&doccats=bt0f6ec0f7a31a841c1&q=NF250-LGV%203P%20125-160A&doc-lang=en

Product Packaging

Product Packaging
Cardboard (g)97
Other paper (g)0
Aluminum (g)0
Steel (g)0
Styrofoam (g)0
Other plastic (g)0
Wood (g)0
Glass (g)0
Others (g)0

Compatible Products

Mechanical Options

MaterialDescription / Price List Text / Classification
225426V-AD3S - Variable-depth handle Adjustment Unit. V-05, V-1, V-2; approx. 300mm. Class 100100902: FA-MCCB: Mechanical Option
235194V-AD5S - Variable-depth handle Adjustment Unit. V-05, V-1, V-2; approx. 500mm. Class 100100902: FA-MCCB: Mechanical Option
250427F-2SVUL LF DR - Op. Type F. OFF Pos. lock, RESET Pos. open, ON up, NF/NV250-CVU/SVU/HVU 3P. Class 100100902: FA-MCCB: Mechanical Option
267249BAF-25V - Front-side insulating barrier, for frame size 125-250A. Class 100100902: FA-MCCB: Mechanical Option
267259BTC-25V3 - Rear terminal cover. NF125, 160, 250-xxx 2 or 3P (W105). Class 100100902: FA-MCCB: Mechanical Option
267359F-25V LF DF - Op. Type F. OFF Pos. lock, OFF Pos. open, ON up, NF125, 160, 250 W105 2, 3, 4P. Class 100100902: FA-MCCB: Mechanical Option
267360F-25V LF DF Y - Op. Type F. OFF Pos. lock, OFF Pos. open, ON L, NF125, 160, 250 W105 2, 3, 4P. Class 100100902: FA-MCCB: Mechanical Option
267361F-25V LF DF Z - Op. Type F. OFF Pos. lock, OFF Pos. open, ON R, NF125, 160, 250 W105 2, 3, 4P. Class 100100902: FA-MCCB: Mechanical Option
267362F-25V LF DR - Op. Type F. OFF Pos. lock, RESET Pos. open, ON up, NF125, 160, 250 W105 2, 3, 4P. Class 100100902: FA-MCCB: Mechanical Option
267363F-25V LF DR Y - Op. Type F. OFF Pos. lock, RESET Pos. open, ON L, NF125, 160, 250 W105 2, 3, 4P. Class 100100902: FA-MCCB: Mechanical Option
267364F-25V LF DR Z - Op. Type F. OFF Pos. lock, RESET Pos. open, ON R, NF125, 160, 250 W105 2, 3, 4P. Class 100100902: FA-MCCB: Mechanical Option
267365F-25V LN DF - Op. Type F. ON/OFF Pos. lock, OFF Pos. open, ON up, NF125, 160, 250 W105 2, 3, 4P. Class 100100902: FA-MCCB: Mechanical Option
267371F-25VE LF DF - Op. Type F Emerg. OFF Pos-lock, OFF Pos-open, ON up, NF125, 160, 250 W105 2, 3, 4P. Class 100100902: FA-MCCB: Mechanical Option
267372F-25VE LF DF Y - Op. Type F Emerg. OFF Pos-lock, OFF Pos-open, ON L, NF125, 160, 250 W105 2, 3, 4P. Class 100100902: FA-MCCB: Mechanical Option
267373F-25VE LF DF Z - Op. Type F Emerg. OFF Pos-lock, OFF Pos-open, ON R, NF125, 160, 250 W105 2, 3, 4P. Class 100100902: FA-MCCB: Mechanical Option
267374F-25VE LF DR - Op. Type F Emerg. OFF Pos-lock, RESET Pos-open, ON up, NF125, 160, 250 W105 2, 3, 4P. Class 100100902: FA-MCCB: Mechanical Option
267375F-25VE LF DR Y - Op. Type F Emerg. OFF Pos-lock, RESET Pos-open, ON L, NF125, 160, 250 W105 2, 3, 4P. Class 100100902: FA-MCCB: Mechanical Option
267376F-25VE LF DR Z - Op. Type F Emerg. OFF Pos-lock, RESET Pos-open, ON R, NF125, 160, 250 W105 2, 3, 4P. Class 100100902: FA-MCCB: Mechanical Option
267394FT-25V3 - Front connection screw terminal - EU Standard. For W105 3-pole. Class 100100902: FA-MCCB: Mechanical Option
267396HLF-055V - Handle lock device removable type. OFF lock. Class 100100902: FA-MCCB: Mechanical Option
267397HLN-055V - Handle lock device removable type. ON lock. Class 100100902: FA-MCCB: Mechanical Option
267400HLS-25V - Handle lock device fix type. OFF lock. For W105. Class 100100902: FA-MCCB: Mechanical Option
267418MI-05SV3 - Mechanical interlock. For W75, W90 and W105; 2 and 3 poles. Panel mounting. Class 100100902: FA-MCCB: Mechanical Option
267425MI-2SVFB3 - Mechanical interlock. For W105; 3 poles. Breaker mounting. Class 100100902: FA-MCCB: Mechanical Option
267436PMD-2SV3 - Base of Plug-In kit without PLT, Safety Device. (W105, 3P). Class 100100902: FA-MCCB: Mechanical Option
267450PMDN-2SV3 - Plug-In kit without PLT, Safety Device. (W105, 3P). Class 100100902: FA-MCCB: Mechanical Option
267464PMN-2SV3 - Connector kit on breaker for Plug in connection. (W105, 3P). Class 100100902: FA-MCCB: Mechanical Option
267474PTC-2SV3 - Terminal Cover for Plug-In. (W90, 2P or 3P). Class 100100902: FA-MCCB: Mechanical Option
267521SL-2SV3L - Solderless terminal. 14 - 95mm², for W105 3-pole. Class 100100902: FA-MCCB: Mechanical Option
267522SL-2SV3G - Solderless terminal. 70 - 125mm², for W105 3-pole. Class 100100902: FA-MCCB: Mechanical Option
267540ST-2SV3 - Rear connection. For NF-SV W105 3-pole. Class 100100902: FA-MCCB: Mechanical Option
267549TCL-2SV3L - Terminal cover - large. For W105 3-pole up to 250A max 150mm². Class 100100902: FA-MCCB: Mechanical Option
267557TCS-2SV3 - Terminal cover - small. For W105 3-pole. Class 100100902: FA-MCCB: Mechanical Option
267565TTC-2SV3 - Terminal cover - transparent. For W105 3-pole. Class 100100902: FA-MCCB: Mechanical Option
267755V-25V - V-handle. For 3 and 4-pole Breaker NF/DSN 125AF, 160AF, 250AF. Handle black. Class 100100902: FA-MCCB: Mechanical Option
267756V-25IVE - V-handle. For 3 and 4-pole Breaker NF/DSN 125AF, 160AF, 250AF. Handle red/yellow. Class 100100902: FA-MCCB: Mechanical Option
267761LC-05SV - Lock cover. Class 100100902: FA-MCCB: Mechanical Option

Electrical Options

MaterialDescription / Price List Text / Classification
267210AL-05SV - Alarm switch. 1CO; Flying lead; Left or Right hand fitting. Class 100100903: FA-MCCB: Electrical Option
267212AL-05SVLS - Alarm switch. 1CO; Terminal block; Left hand fitting. Class 100100903: FA-MCCB: Electrical Option
267213AL-05SVLSB - Alarm switch. 1CO; Terminal block; Left hand fitting. Class 100100903: FA-MCCB: Electrical Option
267226AL-05SVRS - Alarm switch. 1CO; Terminal block; 3P; Right hand fitting. Class 100100903: FA-MCCB: Electrical Option
267228ALAX-05SV - Alarm+Auxiliary switch. 1CO, Flying lead, Left or Right hand fitting. Class 100100903: FA-MCCB: Electrical Option
267230ALAX-05SVLS - Alarm+Auxiliary switch. 1CO, Terminal block, Left hand fitting. Class 100100903: FA-MCCB: Electrical Option
267234ALAX-05SVRS - Alarm+Auxiliary switch. 1CO, Terminal block, 3P, Right hand fitting. Class 100100903: FA-MCCB: Electrical Option
267236AX-05SV - Auxiliary switch. 1CO, Flying lead, Left or Right hand fitting; For 30 to 250A. Class 100100903: FA-MCCB: Electrical Option
267238AX-055VLS - Auxiliary switch. 1CO, Terminal block, Left hand fitting; For 30 to 250A. Class 100100903: FA-MCCB: Electrical Option
267242AX-055VRS - Auxiliary switch. 1CO, Terminal block, 3P, Right hand fitting; For 30 to 250A. Class 100100903: FA-MCCB: Electrical Option
267246AX2-055VLS - Auxiliary switch. 2CO, Terminal block, Left hand fitting; For 30 to 250A. Class 100100903: FA-MCCB: Electrical Option
267402MDSAD240-NF25VE - Electrical operation device. Motor AC 100-240V / DC 100-250V for NF W105. Class 100100903: FA-MCCB: Electrical Option
267407MDSD024-NF2SVE - Electrical operation device. Motor DC 24V for NF W105. Class 100100903: FA-MCCB: Electrical Option
267411MDSD060-NF2SVE - Electrical operation device. Motor DC 48-60V for NF W105. Class 100100903: FA-MCCB: Electrical Option
267415MDSPSAD240-SV - Power supply module for MDS. AC100-240V / DC100-250V. Class 100100903: FA-MCCB: Electrical Option
267416MDSPSD024-SV - Power supply module for MDS. DC 24V. Class 100100903: FA-MCCB: Electrical Option
267417MDSPSD060-SV - Power supply module for MDS. DC 48-60V. Class 100100903: FA-MCCB: Electrical Option
267478SHTA048-05SVR - Shunt trip. AC 24-48V, R hand fitting, for W75, 90, 105. Flying lead. Class 100100903: FA-MCCB: Electrical Option
267479SHTA048-05SVRS - Shunt trip. AC 24-48V, R hand fitting, for W75, 90, 105. Terminal block. Class 100100903: FA-MCCB: Electrical Option
267483SHTA240-05SVR - Shunt trip. AC 100-240V, R hand fitting, for W75, 90, 105. Flying lead. Class 100100903: FA-MCCB: Electrical Option
267484SHTA240-05SVRS - Shunt trip. AC 100-240V, R hand fitting, for W75, 90, 105. Terminal block. Class 100100903: FA-MCCB: Electrical Option
267488SHTA550-05SVR - Shunt trip. AC 380-550V, R hand fitting, for W75, 90, 105. Flying lead. Class 100100903: FA-MCCB: Electrical Option
267489SHTA550-05SVRS - Shunt trip. AC 380-550V, R hand fitting, for W75, 90, 105. Terminal block. Class 100100903: FA-MCCB: Electrical Option
267493SHTD012-05SVR - Shunt trip. DC 12V, R hand fitting, for W75, 90, 105. Flying lead. Class 100100903: FA-MCCB: Electrical Option
267494SHTD012-05SVRS - Shunt trip. DC 12V, R hand fitting, for W75, 90, 105. Terminal block. Class 100100903: FA-MCCB: Electrical Option
267498SHTD036-05SVR - Shunt trip. DC 24-36V, R hand fitting, for W75, 90, 105. Flying lead. Class 100100903: FA-MCCB: Electrical Option
267499SHTD036-05SVRS - Shunt trip. DC 24-36V, R hand fitting, for W75, 90, 105. Terminal block. Class 100100903: FA-MCCB: Electrical Option
267503SHTD048-05SVR - Shunt trip. DC 36-48V, R hand fitting, for W75, 90, 105. Flying lead. Class 100100903: FA-MCCB: Electrical Option
267504SHTD048-05SVRS - Shunt trip. DC 36-48V, R hand fitting, for W75, 90, 105. Terminal block. Class 100100903: FA-MCCB: Electrical Option
267508SHTD125-05SVR - Shunt trip. DC 100-125V, R hand fitting, for W75, 90, 105. Flying lead. Class 100100903: FA-MCCB: Electrical Option
267509SHTD125-05SVRS - Shunt trip. DC 100-125V, R hand fitting, for W75, 90, 105. Terminal block. Class 100100903: FA-MCCB: Electrical Option
267513SHTD250-05SVR - Shunt trip. DC 220-250V, R hand fitting, for W75, 90, 105. Flying lead. Class 100100903: FA-MCCB: Electrical Option
267514SHTD250-05SVRS - Shunt trip. DC 220-250V, R hand fitting, for W75, 90, 105. Terminal block. Class 100100903: FA-MCCB: Electrical Option
267599UVTSA250-05SVR - Under voltage trip. AC 200-250V, Instantaneous, Synch, Right, Flying lead. Class 100100903: FA-MCCB: Electrical Option
267600UVTSA250-05SVRS - Undervoltage Tripping Device; AC 200-250V; 30 to 250A frames; Right pole; with SLT. Class 100100903: FA-MCCB: Electrical Option
267604UVTSA480-05SVR - Under voltage trip. AC 380-480V, Instantaneous, Synch, Right, Flying lead. Class 100100903: FA-MCCB: Electrical Option
267605UVTSA480-05SVRS - Under voltage trip. AC 380-480V, Instantaneous, Synch, Right, Terminal. Class 100100903: FA-MCCB: Electrical Option
267609UVTSA600-05SVR - Under voltage trip. AC 500-600V, Instantaneous, Synch, Right, Flying lead. Class 100100903: FA-MCCB: Electrical Option
267610UVTSA600-05SVRS - Under voltage trip. AC 500-600V, Instantaneous, Synch, Right, Terminal. Class 100100903: FA-MCCB: Electrical Option
267614UVTSAD024-05SVR - Under voltage trip. AC/DC 24V, Instantaneous, Synch, Right, Flying lead. Class 100100903: FA-MCCB: Electrical Option
267615UVTSAD024-05SVRS - Under voltage trip. AC/DC 24V, Instantaneous, Synch, Right, Terminal. Class 100100903: FA-MCCB: Electrical Option
267619UVTSAD048-05SVR - Under voltage trip. AC/DC 48V, Instantaneous, Synch, Right, Flying lead. Class 100100903: FA-MCCB: Electrical Option
267620UVTSAD048-05SVRS - Under voltage trip. AC/DC 48V, Instantaneous, Synch, Right, Terminal. Class 100100903: FA-MCCB: Electrical Option
267624UVTSAD130-05SVR - Under voltage trip. AC/DC 100-130V, Instantaneous, Synch, Right, Flying lead. Class 100100903: FA-MCCB: Electrical Option
267625UVTSAD130-05SVRS - Under voltage trip. AC/DC 100-130V, Instantaneous, Synch, Right, Terminal. Class 100100903: FA-MCCB: Electrical Option
267689UVTSA048-05SVRU05 - Under voltage trip. AC 24/48V, 0.1/0.3/0.5 s, Synch, Right, Flying lead. Class 100100903: FA-MCCB: Electrical Option
267690UVTSA048-05SVRSU05 - Under voltage trip. AC 24/48V, 0.1/0.3/0.5 s, Synch, Right, Terminal. Class 100100903: FA-MCCB: Electrical Option
267694UVTSA450-05SVRU05 - Under voltage trip. AC 120/240/450V, 0.1/0.3/0.5 s, Synch, Right, Flying lead. Class 100100903: FA-MCCB: Electrical Option
267695UVTSA450-05SVRSU05 - Under voltage trip. AC 120/240/450V, 0.1/0.3/0.5 s, Synch, Right, Terminal. Class 100100903: FA-MCCB: Electrical Option
267709UVTSD048-05SVRU05 - Under voltage trip. DC 24/48V, 0.1/0.3/0.5 s, Synch, Right, Flying lead. Class 100100903: FA-MCCB: Electrical Option
267710UVTSD048-05SVRSU05 - Under voltage trip. DC 24/48V, 0.1/0.3/0.5 s, Synch, Right, Terminal. Class 100100903: FA-MCCB: Electrical Option
267724UVTSA450-05SVRU30 - Under voltage trip. AC 120/240/450V, 0.5/1.0/3.0 s, Synch, Right, Flying lead. Class 100100903: FA-MCCB: Electrical Option
267725UVTSA450-05SVRSU30 - Under voltage trip. AC 120/240/450V, 0.5/1.0/3.0 s, Synch, Right, Terminal. Class 100100903: FA-MCCB: Electrical Option
403223AX2-05SVL - Auxiliary switch. 2CO; Flying lead; Left hand fitting; For 30 to 250A. Class 100100903: FA-MCCB: Electrical Option
602591AX2-05SVLB - Auxiliary switch. 2CO; Flying lead; Left pole; For 30 to 250A; Minute load switch. Class 100100903: FA-MCCB: Electrical Option
602612AX2-05SVRB - Auxiliary switch. 2CO; Flying lead; Right pole; For 30 to 250A; Minute load switch. Class 100100903: FA-MCCB: Electrical Option
Models: NF250-LGV 3P Moulded Case Circuit Breaker, NF250-LGV 3P, Moulded Case Circuit Breaker, Case Circuit Breaker, Circuit Breaker, Breaker

File Info : application/pdf, 6 Pages, 274.52KB

PDF preview unavailable. Download the PDF instead.

000000000000255127 20250809 mitsubishi factsheet

References

Adobe LiveCycle Designer 11.0 Adobe XML Form Module Library

Related Documents

Preview Mitsubishi Electric NF250-RGV 3P 125-160A MCCB - Material Fact Sheet
Detailed material fact sheet for the Mitsubishi Electric NF250-RGV 3P 125-160A Moulded-Case Circuit Breaker (MCCB). Includes technical specifications, compliance information, and compatible accessories.
Preview Mitsubishi Electric NF250-HGV 4P 125-160A Moulded-Case Circuit Breaker Fact Sheet
Detailed material fact sheet for the Mitsubishi Electric NF250-HGV 4P 125-160A Moulded-Case Circuit Breaker (MCCB). Includes technical specifications, dimensions, weight, compliance information, and compatible accessories.
Preview Mitsubishi Electric NV125-CV 3P 125A Earth Leakage Circuit Breaker - Technical Specifications
Material fact sheet detailing the Mitsubishi Electric NV125-CV 3P 125A Earth Leakage Circuit Breaker (FA-MCCB). Provides comprehensive technical specifications, dimensions, weight, environmental compliance, and export data for this industrial automation component.
Preview Mitsubishi Electric NF125-LGV 3P 56-80A Moulded-Case Circuit Breaker - Material Fact Sheet
Material fact sheet for the Mitsubishi Electric NF125-LGV 3P 56-80A Moulded-Case Circuit Breaker (FA-MCCB). Details include general data, dimensions, weight, stock information, environmental compliance, and a comprehensive list of compatible accessories and options.
Preview Mitsubishi Electric NF250-SV 3P 200A MCCB Material Fact Sheet
Detailed material fact sheet for the Mitsubishi Electric NF250-SV 3P 200A Moulded-Case Circuit Breaker (MCCB). Provides comprehensive specifications, dimensions, environmental compliance, conformity details, and a list of compatible accessories.
Preview Mitsubishi Electric 255088 NF250-SV 4P 200A MCCB - Material Fact Sheet
Detailed material fact sheet for the Mitsubishi Electric 255088 NF250-SV 4P 200A Moulded-Case Circuit Breaker (MCCB), including specifications, dimensions, compliance, and compatible accessories.
Preview Mitsubishi Electric NF63-HV 3P 20A Moulded-Case Circuit Breaker - Material Fact Sheet
Material fact sheet for the Mitsubishi Electric NF63-HV 3P 20A Moulded-Case Circuit Breaker (MCCB). Details include general data, product dimensions, weight, logistic dimensions, stock data, life cycle, additional product information, export data, environmental compliance (REACH, RoHS, WEEE), conformity certifications (CE, UL/cUL, EAC, UKCA), documentation links, product packaging details, and a list of compatible accessories and options.
Preview Mitsubishi Electric NF32-SV 3P 10A Material Fact Sheet
Material fact sheet for the Mitsubishi Electric NF32-SV 3P 10A moulded-case circuit breaker, detailing technical specifications, dimensions, weight, stock data, and compatible accessories.