Mitsubishi Electric NF125-CV 3P 100A Material Fact Sheet

Mitsubishi Electric

Industrial Automation

Address: Mitsubishi-Electric-Platz 1, 40882 Ratingen, Deutschland

Phone: +49 (0) 2102 486-0, Fax: +49 (0) 2102 486-1120

Website: https://emea.mitsubishielectric.com/fa

MATERIAL FACT SHEET

254813 NF125-CV 3P 100A

General Data

Product Hierarchy IAN10201
Ext. Material Group MCCB
ABC Indicator WS-V 1 - NF Body
e-shop https://mitsubishi-electric-eshop.mee.com/mee/FA_IA/EUR/en/p/000000000000267761

FA-MCCB: Moulded-Case Circuit Breaker

Attribute Value
Series WS-V SERIES - MCCB
Type NF-C TYPE (ECONOMY CLASS)
Frame Size 125
Rated Current (A) 100
Current Type AC/DC
Number of Poles 3
Rated Voltage (V) 600
Breaking Capacity at 400V (kA) 10/5
Compliant with Standard(s) EN 60947-2
Compliant with Standard(s) (2) IEC 60947-2
Cycles with Rated Current 6000
Cycles without Rated Current 10000
Automatic Tripping Device THERMAL-MAGNETIC

Product Dimensions & Weight

Width (mm) 90
Height (mm) 130
Depth (mm) 90
Weight (kg) 0.9

Logistic Dimensions & Gross Weight

Length (cm) 13.5
Width (cm) 10.0
Height (cm) 10.0
Gross Weight (kg) 0.878
Volume (cdm) 1.350

Stock Data

Planned Delivery Time (Days) 77

Life Cycle

Sales Start 06.11.2012
Predecessor 217322 / NF125-CW 3P 100A W

Additional Product Information

Binding Tariff Information DEBTI-20365/24-1
BTI validity date 25.09.2027
Battery included NO

Export Data

Commodity Code 85362010
Legal Control (Dual Use List) Not Listed
Country of Origin Japan (JP)
Preference Status (Supplier Declaration) Non EU

Environmental

REACH Limit Exceeded YES
REACH Substance CAS Number 1306-19-0
REACH Substance CAS Number (2) 119344-86-4
Dangerous Goods Class NO
Dangerous Goods Identifier NO
RoHS Compliance COMPLIANT
WEEE B2B

Conformity

CE COMPLIANT
UL/cUL NON-COMPLIANT
EAC NON-COMPLIANT
Shipping Approvals LR, DNV-GL, BV, ABS, CCS
UKCA COMPLIANT

Documentation & Media Data

Manual URL Indicator Link
Certificates URL Indicator Link
CAD URL Indicator Link

Product Packaging

Cardboard (g) 69
Other paper (g) 0
Aluminum (g) 0
Steel (g) 0
Styrofoam (g) 0
Other plastic (g) 0
Wood (g) 0
Glass (g) 0
Others (g) 0

Compatible Products (Accessories)

Material Description / Price List Text / Classification
267210 AL-05SV - Alarm switch. 1CO; Flying lead; Left or Right hand fitting. Class 100100903: FA-MCCB: Electrical Option
267212 AL-05SVLS - Alarm switch. 1CO; Terminal block; Left hand fitting. Class 100100903: FA-MCCB: Electrical Option
267228 ALAX-05SV - Alarm+Auxiliary switch. 1CO, Flying lead, Left or Right hand fitting. Class 100100903: FA-MCCB: Electrical Option
267230 ALAX-05SVLS - Alarm+Auxiliary switch. 1CO, Terminal block, Left hand fitting. Class 100100903: FA-MCCB: Electrical Option
267236 AX-05SV - Auxiliary switch. 1CO, Flying lead, Left or Right hand fitting; For 30 to 250A. Class 100100903: FA-MCCB: Electrical Option
267238 AX-05SVLS - Auxiliary switch. 1CO, Terminal block, Left hand fitting; For 30 to 250A. Class 100100903: FA-MCCB: Electrical Option
267246 AX2-05SVLS - Auxiliary switch. 2CO; Terminal block, Left hand fitting; For 30 to 250A. Class 100100903: FA-MCCB: Electrical Option
267249 BAF-2SV - Front-side insulating barrier, for frame size 125-250A. Class 100100902: FA-MCCB: Mechanical Option
267257 BTC-1SV3 - Rear terminal cover. NF125-xxx 3P (W90). Class 100100902: FA-MCCB: Mechanical Option
267311 F-1SV LF DF - Op. Type F. OFF Pos-lock, OFF Pos-open, ON up, NF125-CV/SV/HV 3P/4P&HV 2P. Class 100100902: FA-MCCB: Mechanical Option
267312 F-1SV LF DF Y - Op. Type F. OFF Pos-lock, OFF Pos-open, ON L, NF125-CV/SV/HV 3P/4P&HV 2P. Class 100100902: FA-MCCB: Mechanical Option
267313 F-1SV LF DF Z - Op. Type F. OFF Pos-lock, OFF Pos-open, ON R, NF125-CV/SV/HV 3P/4P&HV 2P. Class 100100902: FA-MCCB: Mechanical Option
267314 F-1SV LF DR - Op. Type F. OFF Pos-lock, RESET Pos-open, ON up, NF125-CV/SV/HV 3P/4P&HV 2P. Class 100100902: FA-MCCB: Mechanical Option
267315 F-1SV LF DR Y - Op. Type F. OFF Pos-lock, RESET Pos-open, ON L, NF125-CV/SV/HV 3P/4P&HV 2P. Class 100100902: FA-MCCB: Mechanical Option
267316 F-1SV LF DR Z - Op. Type F. OFF Pos-lock, RESET Pos-open, ON R, NF125-CV/SV/HV 3P/4P&HV 2P. Class 100100902: FA-MCCB: Mechanical Option
267335 F-1SVE LF DF - Op. Type F Emerg. OFF Pos-lock, OFF Pos-open, ON up, NF125-CV/SV/HV 3P/4P&HV 2P. Class 100100902: FA-MCCB: Mechanical Option
267336 F-1SVE LF DF Y - Op. Type F Emerg. OFF Pos-lock, OFF Pos-open, ON L, NF125-CV/SV/HV 3P/4P&HV 2P. Class 100100902: FA-MCCB: Mechanical Option
267337 F-1SVE LF DF Z - Op. Type F Emerg. OFF Pos-lock, OFF Pos-open, ON R, NF125-CV/SV/HV 3P/4P&HV 2P. Class 100100902: FA-MCCB: Mechanical Option
267338 F-1SVE LF DR - Op. Type F Emerg. OFF Pos-lock, RESET Pos-open, ON up, NF125-CV/SV/HV 3P/4P&HV 2P. Class 100100902: FA-MCCB: Mechanical Option
267339 F-1SVE LF DR Y - Op. Type F Emerg. OFF Pos-lock, RESET Pos-open, ON L, NF125-CV/SV/HV 3P/4P&HV 2P. Class 100100902: FA-MCCB: Mechanical Option
267340 F-1SVE LF DR Z - Op. Type F Emerg. OFF Pos-lock, RESET Pos-open, ON R, NF125-CV/SV/HV 3P/4P&HV 2P. Class 100100902: FA-MCCB: Mechanical Option
267396 HLF-05SV - Handle lock device removable type. OFF lock. Class 100100902: FA-MCCB: Mechanical Option
267397 HLN-05SV - Handle lock device removable type. ON lock. Class 100100902: FA-MCCB: Mechanical Option
267398 HLS-05SV - Handle lock device fix type. OFF lock. For W75 and W90. Class 100100902: FA-MCCB: Mechanical Option
267418 MI-05SV3 - Mechanical interlock. For W75, W90 und W105; 2 und 3 poles. Panel mounting. Class 100100902: FA-MCCB: Mechanical Option
267423 MI-1SVFB3 - Mechanical interlock. For W90; 3 poles. Breaker mounting. Class 100100902: FA-MCCB: Mechanical Option
267447 PMDN-1SV3 - Plug-In kit without PLT, Safety Device. (W90, 3P). Class 100100902: FA-MCCB: Mechanical Option
267461 PMN-1SV3 - Connector kit on breaker for Plug in connection. (W90, 3P). Class 100100902: FA-MCCB: Mechanical Option
267479 SHTA048-05SVRS - Shunt trip. AC 24-48V, R hand fitting, for W75, 90, 105. Terminal block. Class 100100903: FA-MCCB: Electrical Option
267480 SHTA048-05SVRFS - Shunt trip. AC 24-48V, R hand fitting 4P, for W75, 90, 105. Terminal block. Class 100100903: FA-MCCB: Electrical Option
267484 SHTA240-05SVRS - Shunt trip. AC 100-240V, R hand fitting, for W75, 90, 105. Terminal block. Class 100100903: FA-MCCB: Electrical Option
267485 SHTA240-05SVRFS - Shunt trip. AC 100-240V, R hand fitting 4P, for W75, 90, 105. Terminal block. Class 100100903: FA-MCCB: Electrical Option
267489 SHTA550-05SVRS - Shunt trip. AC 380-550V, R hand fitting, for W75, 90, 105. Terminal block. Class 100100903: FA-MCCB: Electrical Option
267490 SHTA550-05SVRFS - Shunt trip. AC 380-550V, R hand fitting 4P, for W75, 90, 105. Terminal block. Class 100100903: FA-MCCB: Electrical Option
267494 SHTD012-05SVRS - Shunt trip. DC 12V, R hand fitting, for W75, 90, 105. Terminal block. Class 100100903: FA-MCCB: Electrical Option
267495 SHTD012-05SVRFS - Shunt trip. DC 12V, R hand fitting 4P, for W75, 90, 105. Terminal block. Class 100100903: FA-MCCB: Electrical Option
267499 SHTD036-05SVRS - Shunt trip. DC 24-36V, R hand fitting, for W75, 90, 105. Terminal block. Class 100100903: FA-MCCB: Electrical Option
267500 SHTD036-05SVRFS - Shunt trip. DC 24-36V, R hand fitting 4P, for W75, 90, 105. Terminal block. Class 100100903: FA-MCCB: Electrical Option
267504 SHTD048-05SVRS - Shunt trip. DC 36-48V, R hand fitting, for W75, 90, 105. Terminal block. Class 100100903: FA-MCCB: Electrical Option
267505 SHTD048-05SVRFS - Shunt trip. DC 36-48V, R hand fitting 4P, for W75, 90, 105. Terminal block. Class 100100903: FA-MCCB: Electrical Option
267509 SHTD125-05SVRS - Shunt trip. DC 100-125V, R hand fitting, for W75, 90, 105. Terminal block. Class 100100903: FA-MCCB: Electrical Option
267510 SHTD125-05SVRFS - Shunt trip. DC 100-125V, R hand fitting 4P, for W75, 90, 105. Terminal block. Class 100100903: FA-MCCB: Electrical Option
267514 SHTD250-05SVRS - Shunt trip. DC 220-250V, R hand fitting, for W75, 90, 105. Terminal block. Class 100100903: FA-MCCB: Electrical Option
267515 SHTD250-05SVRFS - Shunt trip. DC 220-250V, R hand fitting 4P, for W75, 90, 105. Terminal block. Class 100100903: FA-MCCB: Electrical Option
267516 SL-1SV3L - Solderless terminal. 2,5 - 25mm², for W90, 3-pole. Class 100100902: FA-MCCB: Mechanical Option
267517 SL-1SV3G - Solderless terminal. 25 - 70mm², for W90, 3-pole. Class 100100902: FA-MCCB: Mechanical Option
267537 ST-1SV3 - Rear connection. For NF-SV W90 3-pole. Class 100100902: FA-MCCB: Mechanical Option
267546 TCL-1SV3 - Terminal cover - large. For W90 3-pole. Class 100100902: FA-MCCB: Mechanical Option
267555 TCS-1SV3 - Terminal cover - small. For W90 3-pole. Class 100100902: FA-MCCB: Mechanical Option
267601 UVTSA250-05SVRFS - Undervoltage Trip; AC 200-250V; 30 to 250A frames; Right pole (4poles); with SLT. Class 100100903: FA-MCCB: Electrical Option
267606 UVTSA480-05SVRFS - Under voltage trip. AC 380-480V, Instantaneous, Synch, Right 4P, Terminal. Class 100100903: FA-MCCB: Electrical Option
267611 UVTSA600-05SVRFS - Under voltage trip. AC 500-600V, Instantaneous, Synch, Right 4P, Terminal. Class 100100903: FA-MCCB: Electrical Option
267616 UVTSAD024-05SVRFS - Under voltage trip. AC/DC 24V, Instantaneous, Synch, Right 4P, Terminal. Class 100100903: FA-MCCB: Electrical Option
267621 UVTSAD048-05SVRFS - Under voltage trip. AC/DC 48V, Instantaneous, Synch, Right 4P, Terminal. Class 100100903: FA-MCCB: Electrical Option
267626 UVTSAD130-05SVRFS - Under voltage trip. AC/DC 100-130V, Instantaneous, Synch, Right 4P, Terminal. Class 100100903: FA-MCCB: Electrical Option
267690 UVTSA048-05SVRSU05 - Under voltage trip. AC 24/48V, 0,1/0,3/0,5 s, Synch, Right, Terminal. Class 100100903: FA-MCCB: Electrical Option
267691 UVTSA048-05SVRFSU05 - Under voltage trip. AC 24/48V, 0,1/0,3/0,5 s, Synch, Right 4P, Terminal. Class 100100903: FA-MCCB: Electrical Option
267695 UVTSA450-05SVRSU05 - Under voltage trip. AC 120/240/450V, 0,1/0,3/0,5 s, Synch, Right, Terminal. Class 100100903: FA-MCCB: Electrical Option
267696 UVTSA450-05SVRFSU05 - Under voltage trip. AC 120/240/450V, 0,1/0,3/0,5 s, Synch, Right 4P, Terminal. Class 100100903: FA-MCCB: Electrical Option
267701 UVTSA550-05SVRFSU05 - Under voltage trip. AC 250/450/550V, 0,1/0,3/0,5 s, Synch, Right 4P, Terminal. Class 100100903: FA-MCCB: Electrical Option
267751 V-1SV - V-handle. For 3 and 4-pole Breaker NF/DSN 125AF fix. Handle black. Class 100100902: FA-MCCB: Mechanical Option
267761 LC-05SV - Lock cover. Class 100100902: FA-MCCB: Mechanical Option

PDF preview unavailable. Download the PDF instead.

000000000000254813 20250818 mitsubishi factsheet Adobe LiveCycle Designer 11.0 Adobe XML Form Module Library

Related Documents

Preview Mitsubishi Electric NF125-CV 3P 100A MCCB - Material Fact Sheet
Detailed material fact sheet for the Mitsubishi Electric NF125-CV 3P 100A Moulded-Case Circuit Breaker (MCCB). Includes technical specifications, dimensions, weight, environmental compliance, and a list of compatible accessories.
Preview Mitsubishi Electric NF125-LGV 3P 56-80A Moulded-Case Circuit Breaker - Material Fact Sheet
Material fact sheet for the Mitsubishi Electric NF125-LGV 3P 56-80A Moulded-Case Circuit Breaker (FA-MCCB). Details include general data, dimensions, weight, stock information, environmental compliance, and a comprehensive list of compatible accessories and options.
Preview Mitsubishi Electric NF63-HV 3P 20A Moulded-Case Circuit Breaker - Material Fact Sheet
Material fact sheet for the Mitsubishi Electric NF63-HV 3P 20A Moulded-Case Circuit Breaker (MCCB). Details include general data, product dimensions, weight, logistic dimensions, stock data, life cycle, additional product information, export data, environmental compliance (REACH, RoHS, WEEE), conformity certifications (CE, UL/cUL, EAC, UKCA), documentation links, product packaging details, and a list of compatible accessories and options.
Preview Mitsubishi Electric NF32-SV 3P 10A Material Fact Sheet
Material fact sheet for the Mitsubishi Electric NF32-SV 3P 10A moulded-case circuit breaker, detailing technical specifications, dimensions, weight, stock data, and compatible accessories.
Preview Mitsubishi Electric DSN1600-SW 4P 1600A Material Fact Sheet
Technical specifications and material fact sheet for the Mitsubishi Electric DSN1600-SW 4P 1600A Moulded-Case Circuit Breaker (MCCB), detailing dimensions, weight, stock data, life cycle, export information, environmental compliance, and product packaging.
Preview Mitsubishi Electric 433090 NV50-SVFU 2P 30A 120-240V 30MA Circuit Breaker - Material Fact Sheet
Technical specifications and material fact sheet for the Mitsubishi Electric 433090 NV50-SVFU 2P 30A 120-240V 30MA Earth Leakage Circuit Breaker, including dimensions, compliance, and packaging data.
Preview Mitsubishi Electric NV125-CV 3P 125A Earth Leakage Circuit Breaker - Technical Specifications
Material fact sheet detailing the Mitsubishi Electric NV125-CV 3P 125A Earth Leakage Circuit Breaker (FA-MCCB). Provides comprehensive technical specifications, dimensions, weight, environmental compliance, and export data for this industrial automation component.
Preview Mitsubishi Electric NF250-SV 3P 200A MCCB Material Fact Sheet
Detailed material fact sheet for the Mitsubishi Electric NF250-SV 3P 200A Moulded-Case Circuit Breaker (MCCB). Provides comprehensive specifications, dimensions, environmental compliance, conformity details, and a list of compatible accessories.